4-D ICE: A 2-D Array Transducer With Integrated ASIC in a 10-Fr Catheter for Real-Time 3-D Intracardiac Echocardiography

被引:72
|
作者
Wildes, Douglas [1 ]
Lee, Warren [1 ]
Haider, Bruno [1 ,2 ]
Cogan, Scott [1 ,3 ]
Sundaresan, Krishnakumar [1 ]
Mills, David M. [1 ]
Yetter, Christopher [1 ]
Hart, Patrick H. [1 ,4 ]
Haun, Christopher R. [1 ]
Concepcion, Mikael [5 ,6 ]
Kirkhorn, Johan [7 ]
Bitoun, Marc [8 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
[2] GE Healthcare, Phoenix, AZ 85040 USA
[3] Michigan State Univ, E Lansing, MI 48824 USA
[4] GE Fuel Cells, Malta, NY 12020 USA
[5] Thomas Med Prod, Malvern, PA 19355 USA
[6] Merit Med Syst Inc, Malvern, PA 19355 USA
[7] GE Vingmed Ultrasound, N-3191 Horten, Norway
[8] Shifamed LLC, Campbell, CA 95008 USA
关键词
Application-specific integrated circuit (ASIC); catheters; four-dimensional (4-D); intracardiac; three-dimensional (3-D); two-dimensional (2-D) array; ultrasonic transducer arrays; ATRIAL SEPTAL-DEFECT; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; DEVICE CLOSURE; INITIAL-EXPERIENCE; MATRIX TRANSDUCER; ULTRASOUND; ABLATION; SYSTEM; INTERVENTIONS; FEASIBILITY;
D O I
10.1109/TUFFC.2016.2615602
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
We developed a 2.5x6.6 mm(2) 2-D array transducer with integrated transmit/receive application-specific integrated circuit (ASIC) for real-time 3-D intracardiac echocardiography (4-D ICE) applications. The ASIC and transducer design were optimized so that the high-voltage transmit, low-voltage time-gain control and preamp, subaperture beamformer, and digital control circuits for each transducer element all fit within the 0.019-mm(2) area of the element. The transducer assembly was deployed in a 10-Fr (3.3-mm diameter) catheter, integrated with a GE Vivid E9 ultrasound imaging system, and evaluated in three preclinical studies. The 2-D image quality and imaging modes were comparable to commercial 2-D ICE catheters. The 4-D field of view was at least 90 degrees x 60 degrees x 8 cm and could be imaged at 30 vol/s, sufficient to visualize cardiac anatomy and other diagnostic and therapy catheters. 4-D ICE should significantly reduce X-ray fluoroscopy use and dose during electrophysiology ablation procedures. 4-D ICE may be able to replace transesophageal echocardiography (TEE), and the associated risks and costs of general anesthesia, for guidance of some structural heart procedures.
引用
收藏
页码:2159 / 2173
页数:15
相关论文
共 50 条
  • [1] A 10-Fr Ultrasound Catheter With Integrated Micromotor for 4-D Intracardiac Echocardiography
    Lee, Warren
    Griffin, Weston
    Wildes, Douglas
    Buckley, Donald
    Topka, Terry
    Chodakauskas, Thaddeus
    Langer, Mark
    Calisti, Serge
    Bergstol, Svein
    Malacrida, Jean-Pierre
    Lanteri, Frederic
    Maffre, Jennifer
    McDaniel, Ben
    Shivkumar, Kalyanam
    Cummings, Jennifer
    Callans, David
    Silvestry, Frank
    Packer, Douglas
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (07) : 1478 - 1491
  • [2] A miniaturized catheter 2-D array for real-time, 3-D intracardiac echo cardiography
    Lee, W
    Idriss, SF
    Wolf, PD
    Smith, SW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2004, 51 (10) : 1334 - 1346
  • [3] Advances in 2-D array catheter transducers for real-time three-dimensional intracardiac echocardiography
    Lee, W
    Idriss, SF
    Wolf, PD
    Dixon-Tulloch, E
    Angle, JF
    Smith, SW
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 672 - 675
  • [4] Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation
    Gentry, KL
    Smith, SW
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 1099 - 1102
  • [5] Integrated catheter for 3-D intracardiac echocardiography and ultrasound ablation
    Gentry, KL
    Smith, SW
    2003 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2003, : 994 - 997
  • [6] Real-time 3-D stress echocardiography: Impact of contrast enhancement and comparison with conventional 2-D stress echocardiography
    Ahmad, M
    Xie, TR
    McCulloch, M
    Abreo, G
    Heredia, R
    Adams, M
    Runge, MS
    CIRCULATION, 1999, 100 (18) : 71 - 71
  • [7] New observations in comparison of real-time 3-D dobutamine stress echocardiography with conventional 2-D dobutamine stress echocardiography
    Xie, T
    Heredia, R
    Ahmad, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 442A - 443A
  • [8] Real-time 3-D intracranial ultrasound with an endoscopic matrix array transducer
    Light, Edward D.
    Mukundan, Srinivasan
    Wolf, Patrick D.
    Smith, Stephen W.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (08): : 1277 - 1284
  • [9] MULTIVIEW FUSION 3-D ECHOCARDIOGRAPHY: IMPROVING THE INFORMATION AND QUALITY OF REAL-TIME 3-D ECHOCARDIOGRAPHY
    Rajpoot, Kashif
    Grau, Vicente
    Noble, J. Alison
    Szmigielski, Cezary
    Bechery, Harald
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (07): : 1056 - 1072
  • [10] Real-time 3D Imaging using 2-D curved array
    Kim, KS
    Han, HS
    Chang, SH
    Song, TK
    2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1713 - 1716