The great myth of office blood pressure measurement

被引:87
|
作者
Myers, Martin G. [1 ,2 ]
机构
[1] Sunnybrook Hlth Sci Ctr, Div Cardiol, Schulich Heart Program, Toronto, ON M4N 3M5, Canada
[2] Univ Toronto, Dept Med, Toronto, ON, Canada
关键词
automated sphygmomanometers; blood pressure measurement; EDUCATION-PROGRAM RECOMMENDATIONS; HYPERTENSION; ALGORITHM; RELIABILITY; VALIDATION; DIAGNOSIS; IMPACT; SELF;
D O I
10.1097/HJH.0b013e3283577b05
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Clinical practice guidelines have traditionally recommended manual blood pressure (BP) measurement in the office setting as the standard method for diagnosing hypertension. In reality, manual BP in routine clinical practice is relatively inaccurate, over-diagnoses hypertension by provoking office-induced increases in BP and correlates poorly with both the awake ambulatory BP and target organ damage. The most recent guidelines recommend 24-h ambulatory BP and home BP for diagnosing hypertension. The advent of automated office BP (AOBP) represents a third alternative to conventional manual BP measurement, one that maintains the role of office BP readings in the diagnosis and management of hypertension. AOBP has three basic principles: multiple readings taken using a fully automated sphygmomanometer with the patient resting quietly alone. AOBP eliminates office-induced hypertension such that the cut-point for a normal AOBP is the same as for the awake ambulatory BP and home BP. As compared to routine manual office BP, AOBP provides more accurate BP readings, is more consistent during repeated office visits and in different settings and correlates better with both the awake ambulatory BP and target organ damage. The advantages of AOBP over manual BP measurement support its use in routine clinical practice.
引用
收藏
页码:1894 / 1898
页数:5
相关论文
共 50 条
  • [21] How to cope with unreliable office blood pressure measurement?
    Stergiou, GS
    AMERICAN JOURNAL OF HYPERTENSION, 2005, 18 (12) : 1519 - 1521
  • [22] Eliminating the Human Factor in Office Blood Pressure Measurement
    Myers, Martin G.
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (02): : 83 - 86
  • [23] Eliminating the Human Factor in Office Blood Pressure Measurement
    Myers, Martin G.
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (07): : 541 - 542
  • [24] Is Office Blood Pressure Measurement Reliable in Obese Adolescents?
    Tepe, Derya
    Yilmaz, Songul
    DIABETES METABOLIC SYNDROME AND OBESITY-TARGETS AND THERAPY, 2021, 14 : 3809 - 3817
  • [25] Barriers to Accurate Blood Pressure Measurement in the Medical Office
    Hwang, Kevin O.
    Aigbe, Aitebureme
    Ju, Hsiao-Hui
    Jackson, Victoria C.
    Sedlock, Emily W.
    JOURNAL OF PRIMARY CARE AND COMMUNITY HEALTH, 2018, 9
  • [26] Unattended automated office blood pressure measurement in children
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    BLOOD PRESSURE, 2021, 30 (06) : 359 - 366
  • [28] UNATTENDED AUTOMATED OFFICE BLOOD PRESSURE MEASUREMENT IN CHILDREN
    Seeman, Tomas
    Stanek, Krystof
    Slizek, Jakub
    Filipovsky, Jan
    Feber, Janusz
    PEDIATRIC NEPHROLOGY, 2022, 37 (11) : 2812 - 2812
  • [29] The Fallacy of Attended Automated Office Blood Pressure Measurement
    Myers, Martin G.
    AMERICAN JOURNAL OF HYPERTENSION, 2018, 31 (07) : 755 - 757
  • [30] Comparison of routine and automated office blood pressure measurement
    Chen, Robin Z.
    Bhalla, Vivek
    Chang, Tara, I
    BLOOD PRESSURE MONITORING, 2019, 24 (04) : 174 - 178