External Calibration of the Spectral Coverage for Three-Dimensional Multispectral MRI

被引:19
|
作者
Kaushik, S. Sivaram [1 ]
Marszalkowski, Cathy [2 ]
Koch, Kevin M. [1 ,2 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Radiol, 8700 W Wisconsin Ave, Milwaukee, WI 53226 USA
关键词
spectral-calibration; MAVRIC-SL; frequency map; 3D-MSI; METAL ARTIFACT CORRECTION; FAST SPIN-ECHO; HIP-ARTHROPLASTY; IMPLANTS; IMPACT;
D O I
10.1002/mrm.26065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: By combining images created at distinct frequency offsets from the Larmor frequency, three-dimensional (3D) multispectral imaging (3D-MSI) sequences help overcome the large spatial frequency dispersion caused by metal implants. This frequency dispersion, however, varies with the implant size, orientation, and composition. Using a MAVRIC 3D-MSI acquisition, we sought to prospectively calibrate the spectral coverage needed for 3D-MSI scans. This calibration should offer a significant improvement to image quality, and reduce the scan time. Methods: The 24 spectral bins from the calibration scan were used to generate a map of frequency offsets around the implant. The magnitude image was used to remove any outliers in the associated frequency offset map, and this processed map was used to determine the cutoff frequency offset and, hence, number of spectral bins. This approach was tested in 13 subjects, by retrospectively reconstructing MAVRIC-SL images with fewer spectral bins. Subsequently, the spectral coverage for MAVRIC-SL images was prospectively calibrated in six subjects, and based on the cutoff frequency offset, these images were acquired with fewer spectral bins. Results: With fewer spectral bins, both retrospectively and prospectively calibrated MAVRIC-SL images adequately delineated the implant boundary. Conclusion: Incorporating this calibration procedure into future 3D-MSI exams will help improve image signal-to-noise ratio, reduce scan time, and significantly improve clinical workflow when imaging near orthopedic implants. (C) 2015 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1494 / 1503
页数:10
相关论文
共 50 条
  • [31] Three-dimensional spectral-spatial excitation
    Morrell, G
    Macovski, A
    MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (03) : 378 - 386
  • [32] Spectral properties of three-dimensional Anderson model
    Suntajs, J.
    Prosen, T.
    Vidmar, L.
    ANNALS OF PHYSICS, 2021, 435
  • [33] Three-dimensional in vivo imaging by spectral OCT
    Bajraszewski, T
    Wojtkowski, M
    Targowski, P
    Szkulmowski, M
    Kowalczyk, A
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE VIII, 2004, 5316 : 226 - 232
  • [34] Spectral properties of the three-dimensional Hubbard model
    Fuchs, Sebastian
    Gull, Emanuel
    Troyer, Matthias
    Jarrell, Mark
    Pruschke, Thomas
    PHYSICAL REVIEW B, 2011, 83 (23)
  • [35] Three-dimensional spectral solution of Schrodinger equation
    Trellakis, A
    Ravaioli, U
    VLSI DESIGN, 2001, 13 (1-4) : 341 - 347
  • [36] Spectral analysis of three-dimensional photonic jets
    Devilez, Alexis
    Stout, Brian
    Bonod, Nicolas
    Popov, Evgeny
    OPTICS EXPRESS, 2008, 16 (18): : 14200 - 14212
  • [37] Spectral analysis for a three-dimensional superradiance problem
    SenGupta, Indranil
    JOURNAL OF MATHEMATICAL ANALYSIS AND APPLICATIONS, 2011, 375 (02) : 762 - 776
  • [38] Construction and calibration of an instrument for three-dimensional ion imaging
    Koszinowski, Konrad
    Goldberg, Noah T.
    Pomerantz, Andrew E.
    Zare, Richard N.
    JOURNAL OF CHEMICAL PHYSICS, 2006, 125 (13):
  • [39] Backward automatic calibration for three-dimensional landslide models
    Titti, Giacomo
    Bossi, Giulia
    Zhou, Gordon G. D.
    Marcato, Gianluca
    Pasuto, Alessandro
    GEOSCIENCE FRONTIERS, 2021, 12 (01) : 231 - 241