External Calibration of the Spectral Coverage for Three-Dimensional Multispectral MRI

被引:19
|
作者
Kaushik, S. Sivaram [1 ]
Marszalkowski, Cathy [2 ]
Koch, Kevin M. [1 ,2 ]
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Radiol, 8700 W Wisconsin Ave, Milwaukee, WI 53226 USA
关键词
spectral-calibration; MAVRIC-SL; frequency map; 3D-MSI; METAL ARTIFACT CORRECTION; FAST SPIN-ECHO; HIP-ARTHROPLASTY; IMPLANTS; IMPACT;
D O I
10.1002/mrm.26065
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: By combining images created at distinct frequency offsets from the Larmor frequency, three-dimensional (3D) multispectral imaging (3D-MSI) sequences help overcome the large spatial frequency dispersion caused by metal implants. This frequency dispersion, however, varies with the implant size, orientation, and composition. Using a MAVRIC 3D-MSI acquisition, we sought to prospectively calibrate the spectral coverage needed for 3D-MSI scans. This calibration should offer a significant improvement to image quality, and reduce the scan time. Methods: The 24 spectral bins from the calibration scan were used to generate a map of frequency offsets around the implant. The magnitude image was used to remove any outliers in the associated frequency offset map, and this processed map was used to determine the cutoff frequency offset and, hence, number of spectral bins. This approach was tested in 13 subjects, by retrospectively reconstructing MAVRIC-SL images with fewer spectral bins. Subsequently, the spectral coverage for MAVRIC-SL images was prospectively calibrated in six subjects, and based on the cutoff frequency offset, these images were acquired with fewer spectral bins. Results: With fewer spectral bins, both retrospectively and prospectively calibrated MAVRIC-SL images adequately delineated the implant boundary. Conclusion: Incorporating this calibration procedure into future 3D-MSI exams will help improve image signal-to-noise ratio, reduce scan time, and significantly improve clinical workflow when imaging near orthopedic implants. (C) 2015 International Society for Magnetic Resonance in Medicine
引用
收藏
页码:1494 / 1503
页数:10
相关论文
共 50 条
  • [21] Single-frame three-dimensional imaging using spectral-coded patterns and multispectral snapshot cameras
    Zhang, Chen
    Brehm, Anika
    Breitbarth, Andreas
    Rosenberger, Maik
    Notni, Gunther
    OPTICAL ENGINEERING, 2018, 57 (12)
  • [22] External cervical resorption: a three-dimensional classification
    Patel, S.
    Foschi, F.
    Mannocci, F.
    Patel, K.
    INTERNATIONAL ENDODONTIC JOURNAL, 2018, 51 (02) : 206 - 214
  • [23] Three-dimensional load measurements in an external fixator
    Seide, K
    Weinrich, N
    Wenzl, ME
    Wolter, D
    Jürgens, C
    JOURNAL OF BIOMECHANICS, 2004, 37 (09) : 1361 - 1369
  • [24] Hardware accelerated representation for three-dimensional radar coverage
    College of Information System and Management, National Univ. of Defense Technology, Changsha 410073, China
    Guofang Keji Daxue Xuebao, 2007, 6 (49-53):
  • [25] The coverage problem in three-dimensional wireless sensor networks
    Huang, CF
    Tseng, YC
    Lo, LC
    GLOBECOM '04: IEEE GLOBAL TELECOMMUNICATIONS CONFERENCE, VOLS 1-6, 2004, : 3182 - 3186
  • [26] Three-dimensional modeling with national coverage: case of The Netherlands
    Stotera, Jantien
    van den Brink, Linda
    Beetz, Jakob
    Ledoux, Hugo
    Reuvers, Marcel
    Janssen, Paul
    Penninga, Friso
    Vosselman, George
    Elberink, Sander Oude
    GEO-SPATIAL INFORMATION SCIENCE, 2013, 16 (04) : 267 - 276
  • [27] Three-dimensional coverage planning for an underwater inspection robot
    Englot, Brendan
    Hover, Franz S.
    INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2013, 32 (9-10): : 1048 - 1073
  • [28] Coverage and connectivity in three-dimensional underwater sensor networks
    Alam, S. M. Nazrul
    Haas, Zygmunt J.
    WIRELESS COMMUNICATIONS & MOBILE COMPUTING, 2008, 8 (08): : 995 - 1009
  • [29] Three-dimensional measurement of the vocal tract by MRI
    Demolin, D
    Metens, T
    Soquet, A
    ICSLP 96 - FOURTH INTERNATIONAL CONFERENCE ON SPOKEN LANGUAGE PROCESSING, PROCEEDINGS, VOLS 1-4, 1996, : 272 - 275
  • [30] A three-dimensional MRI analysis of knee kinematics
    Patel, VV
    Hall, K
    Ries, M
    Lotz, J
    Ozhinsky, E
    Lindsey, C
    Lu, Y
    Majumdar, S
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (02) : 283 - 292