Modelling the effect of non-ideal load in three-phase converter dynamics

被引:5
|
作者
Puukko, J. [1 ]
Suntio, T. [1 ]
机构
[1] Tampere Univ Technol, Dept Elect Energy Engn, FIN-33101 Tampere, Finland
关键词
CONTROL DESIGN;
D O I
10.1049/el.2011.3663
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dynamic modelling of a switched-mode converter describes the internal dynamics of the converter and is computed using ideal source and load systems. Only by taking into account the effect of non-ideal source and load impedances can the converter dynamics be described reliably. This can be easily done for DC-DC converters. So far only the source-effect for the dynamics of three-phase converters has been published in the literature. Formulated is the effect of non-ideal load impedance in three-phase DC-AC converters for the first time. Using the procedures described, a thorough understanding of three-phase DC-AC converter dynamics can be achieved.
引用
收藏
页码:402 / U143
页数:2
相关论文
共 50 条
  • [31] A novel digital control strategy of three-phase shunt active power filter under non-ideal mains voltages
    Zhi-kun Hu
    Zhi-wen Chen
    Chang-chun Hua
    Hui-hai Wang
    Jia-feng Ding
    Journal of Central South University of Technology, 2011, 18 : 2021 - 2030
  • [32] Efficiency analysis of non ideal three-phase triple circuit
    Wu F.
    Huo G.
    Peng S.
    Li H.
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2020, 48 (02): : 93 - 98
  • [33] Cascade Control of Non-Ideal Boost Power Converter
    Ravichandran, Shama
    Patnaik, Sanjib Kumar
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2023, 51 (16) : 1730 - 1739
  • [34] MODULATED WIDEBAND CONVERTER WITH NON-IDEAL LOWPASS FILTERS
    Chen, Yilun
    Mishali, Moshe
    Eldar, Yonina C.
    Hero, Alfred O., III
    2010 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2010, : 3630 - 3633
  • [35] Stability criterion for three-phase AC power systems with converter load
    Liu, Z. (zeng.liu@ieee.org), 2012, Chinese Society for Electrical Engineering (32):
  • [36] Numerical modelling of underwater detonation of non-ideal condensed-phase explosives
    Schoch, Stefan
    Nikiforakis, Nikolaos
    PHYSICS OF FLUIDS, 2015, 27 (01)
  • [37] Active Power Decoupling Control of Three-phase Converter With Unbalanced Load
    Xu Z.
    Tang F.
    Zhou J.
    Xin Z.
    Loh P.C.
    Dianwang Jishu/Power System Technology, 2019, 43 (03): : 1056 - 1065
  • [38] Research on grid connection converter of three-phase power electronic load
    Wu, Zhen-Xing
    Zou, Xu-Dong
    Huang, Qing-Jun
    Zhang, Zhe-Yu
    Zou, Yun-Ping
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (24): : 1 - 7
  • [39] Three-phase immittance converter
    Irie, H
    Nishisako, T
    ELECTRICAL ENGINEERING IN JAPAN, 2003, 145 (01) : 52 - 58
  • [40] An analysis of three-phase four-wire active power filter for harmonic elimination reactive power compensation and load balancing under non-ideal mains voltage
    Ucar, M
    Ozdemir, E
    Kale, M
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 3089 - 3094