Modelling the effect of non-ideal load in three-phase converter dynamics

被引:5
|
作者
Puukko, J. [1 ]
Suntio, T. [1 ]
机构
[1] Tampere Univ Technol, Dept Elect Energy Engn, FIN-33101 Tampere, Finland
关键词
CONTROL DESIGN;
D O I
10.1049/el.2011.3663
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Dynamic modelling of a switched-mode converter describes the internal dynamics of the converter and is computed using ideal source and load systems. Only by taking into account the effect of non-ideal source and load impedances can the converter dynamics be described reliably. This can be easily done for DC-DC converters. So far only the source-effect for the dynamics of three-phase converters has been published in the literature. Formulated is the effect of non-ideal load impedance in three-phase DC-AC converters for the first time. Using the procedures described, a thorough understanding of three-phase DC-AC converter dynamics can be achieved.
引用
收藏
页码:402 / U143
页数:2
相关论文
共 50 条
  • [21] Modelling of second generation derivatives: Ideal and non-ideal interfaces
    Reiner, ES
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2003, 225 : U608 - U608
  • [22] Non-ideal mixing and dynamics of phase separation in fluid lipid billayers
    Yee, Chanel K.
    Butti, Annapoorna R. S.
    Szmodis, Alan W.
    Dixit, Sanhita S.
    Parikh, Atul N.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U1240 - U1240
  • [23] Modelling rational inquiry in non-ideal agents
    Moreno, A
    AI COMMUNICATIONS, 2001, 14 (01) : 63 - 64
  • [24] Adaptive Linear Neural Network Approach for Three-Phase Four-Wire Active Power Filtering under Non-Ideal Grid and Unbalanced Load Scenarios
    Hoon, Yap
    Mohd Radzi, Mohd Amran
    Al-Ogaili, Ali Saadon
    APPLIED SCIENCES-BASEL, 2019, 9 (24):
  • [25] Modelling distributed generations in three-phase distribution load flow
    Teng, J. -H.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2008, 2 (03) : 330 - 340
  • [26] A novel digital control strategy of three-phase shunt active power filter under non-ideal mains voltages
    胡志坤
    陈志文
    华长春
    王会海
    丁家峰
    Journal of Central South University of Technology, 2011, 18 (06) : 2021 - 2030
  • [27] Active disturbance rejection control of three-phase LCL power conversion system under non-ideal grid conditions
    Wang, Sue
    Yang, Junbo
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [28] A novel digital control strategy of three-phase shunt active power filter under non-ideal mains voltages
    Hu Zhi-kun
    Chen Zhi-wen
    Hua Chang-chun
    Wang Hui-hai
    Ding Jia-feng
    JOURNAL OF CENTRAL SOUTH UNIVERSITY OF TECHNOLOGY, 2011, 18 (06): : 2021 - 2030
  • [29] Rapid Extraction of the Fundamental Components for Non-Ideal Three-Phase Grid Based on an Improved Sliding Discrete Fourier Transform
    Li, Kai
    Nai, Wei
    ELECTRONICS, 2022, 11 (12)
  • [30] Control of a Three-Phase Grid-Connected Inverter Under Non-Ideal Grid Conditions With Online Parameter Update
    Chowdhury, Vikram Roy
    Kimball, Jonathan W.
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2019, 34 (03) : 1613 - 1622