Variation of the track etch rate along the trajectories of light ions in CR-39

被引:0
|
作者
Dörschel, B [1 ]
Hermsdorf, D [1 ]
Kadner, K [1 ]
Starke, S [1 ]
机构
[1] Tech Univ Dresden, Inst Radiat Protect Phys, Phys Dept, D-01062 Dresden, Germany
关键词
light ions; track length; ion range; track etch rate; restricted energy loss; CR-39;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The track etch rate has been found to be described by a generalised function of the restricted energy loss in good approximation along the trajectories of protons, deuterons and alpha particles. Extending the studies to tracks of Li-7, B-11 and C-12 ions, curves for the track etch rates as a function of the depth within the detector were obtained the shape of which is like that of the Bragg curve in principle, In detail, however, systematic deviations from a unique correlation of the track etch rate with the restricted energy loss are observed which are more distinct the heavier the ion and the lower its initial energy, This effect is explained by a gradual increase of the track etch rate to the value expected at a given restricted energy loss. At the beginning of the etching process the track etch rate is, therefore, lower than the value observed for larger depths when the same restricted energy loss is presumed. (C) 2002 Published by Elsevier Science Ltd.
引用
收藏
页码:177 / 182
页数:6
相关论文
共 50 条
  • [41] AUTOMATED TRACK MEASUREMENTS IN CR-39
    ADAMS, JH
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1980, 4 (02): : 67 - 76
  • [42] Determination of bulk etch rate for CR-39 nuclear track detectors using an X-ray fluorescence method
    Papachristodoulou, C.
    Patiris, D.
    Ioannides, K. G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2007, 264 (01): : 177 - 182
  • [43] Many-hit model calculations for track etch rate in CR-39 SSNTD using confocal microscope data
    Fromm, M
    Awad, EM
    Ditlov, V
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2004, 226 (04): : 565 - 574
  • [44] Applicability of the multi-hit model to calculate the track etch rate in μm-scale in CR-39 detectors
    Awad, EM
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2003, 158 (07): : 539 - 550
  • [45] Bulk Etch Rate of CR-39 Track Detector Exposed to Gamma Dose Using D-Le Method
    Kasim, Y. Y.
    JORDAN JOURNAL OF PHYSICS, 2015, 8 (04): : 217 - 226
  • [46] Effects of Chemical Solution Temperature on the Bulk Etch Rate of the Detector CR-39
    Al-Nia'emi, Sa'eed Hassan Sa'eed
    JORDAN JOURNAL OF PHYSICS, 2015, 8 (01): : 49 - 55
  • [47] Measurement of general etch rate for CR-39 plastic at short distance scale
    He, Y.D.
    Hancox, C.I.
    Solarz, M.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 132 (01): : 109 - 113
  • [48] Measurement of general etch rate for CR-39 plastic at short distance scale
    He, YD
    Hancox, CI
    Solarz, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 132 (01): : 109 - 113
  • [49] Dose-rate effects on the bulk etch-rate of CR-39 track detector exposed to low-LET radiations
    Yamauchi, T
    Taniguchi, T
    Oda, K
    Ikeda, T
    Honda, Y
    Tagawa, S
    RADIATION MEASUREMENTS, 1999, 31 (1-6) : 121 - 126
  • [50] MAKROFOL AND CR-39 RECOIL TRACK ETCH DETECTORS AS A SUPPLEMENT OF A UNIVERSAL ALBEDO NEUTRON DOSIMETER
    PIESCH, E
    JASIAK, J
    URBAN, M
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1984, 8 (1-4): : 323 - 326