Reverse transcription-loop-mediated isothermal amplification for the detection of rodent coronaviruses

被引:10
|
作者
Hanaki, Ken-Ichi [1 ]
Ike, Fumio [2 ]
Hatakeyama, Rika [1 ]
Hirano, Norio [3 ]
机构
[1] Iwate Med Univ, Inst Biomed Sci, Dept Lab Anim Med, Yahaba, Iwate 0283694, Japan
[2] RIKEN BioResource Ctr, Expt Anim Div, Tsukuba, Ibaraki 3050074, Japan
[3] Iwate Univ, Fac Agr, Morioka, Iwate 0208550, Japan
关键词
Loop-mediated isothermal amplification; Mouse hepatitis virus; Rat coronavirus; Rodent coronavirus; RT-LAMP; MOUSE HEPATITIS-VIRUS; POLYMERASE-CHAIN-REACTION; CELL-LINE; RAPID DETECTION; NATURAL OUTBREAK; PLAQUE-FORMATION; FECAL SPECIMENS; NUDE-MICE; REPLICATION; INFECTION;
D O I
10.1016/j.jviromet.2012.10.008
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mouse hepatitis virus (MHV) is one of the most prevalent viruses detected in laboratory mouse colonies. Enterotropic strains predominate in natural infections, and molecular techniques for the detection of MHV shedding in feces are powerful enough to diagnose active infections. A reverse transcription-loop-mediated isothermal amplification (RT-LAMP) technique was developed for the detection of rodent coronaviruses within 90 min. The specificity of this technique was confirmed by its ability to detect all 17 different strains of MHV and 6 strains of rat coronaviruses as well as its failure to detect human, bovine, and porcine coronaviruses nonspecifically. The sensitivity of RT-LAMP was 3.2-fold higher than that of reverse transcription-polymerase chain reaction (RT-PCR) and 31.6-fold lower than that of nested RT-PCR. An evaluation of the diagnostic performance of RT-LAMP performed in duplicate using mouse fecal specimens showed that the sensitivity and specificity with respect to nested RT-PCR were 85.7% and 100%, respectively. RT-LAMP assays would be suitable for monitoring active MHV infection in mouse colonies. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:222 / 227
页数:6
相关论文
共 50 条
  • [41] Rapid detection and differentiation of dengue virus serotypes by a real-time reverse transcription-loop-mediated isothermal amplification assay
    Parida, M
    Horioke, K
    Ishida, H
    Dash, PK
    Saxena, P
    Jana, AM
    Islam, MA
    Inoue, S
    Hosaka, N
    Morita, K
    JOURNAL OF CLINICAL MICROBIOLOGY, 2005, 43 (06) : 2895 - 2903
  • [42] Development of a reverse transcription-loop-mediated isothermal amplification (RT-LAMP) system for rapid detection of HDV genotype 1
    Wang, C.
    Shen, X.
    Lu, J.
    Zhang, L.
    LETTERS IN APPLIED MICROBIOLOGY, 2013, 56 (03) : 229 - 235
  • [43] Development of reverse transcription-loop-mediated isothermal amplification assay for the detection of genetically different isolates of maize dwarf mosaic virus
    Trzmiel, Katarzyna
    Hasiow-Jaroszewska, Beata
    JOURNAL OF PLANT PROTECTION RESEARCH, 2022, 62 (03) : 302 - 306
  • [44] Detection of murine norovirus by reverse transcription loop-mediated isothermal amplification
    Hanaki, Ken-Ichi
    Ike, Fumio
    Kajita, Ayako
    Yasuno, Wataru
    Yanagiba, Misato
    Goto, Motoki
    Sakai, Kouji
    Ami, Yasushi
    Kyuwa, Shigeru
    JOURNAL OF VIROLOGICAL METHODS, 2014, 204 : 17 - 24
  • [45] Development and evaluation of a reverse transcription-loop-mediated isothermal amplification assay for rapid and high-sensitive detection of Cryptosporidium in water samples
    Inomata, A.
    Kishida, N.
    Momoda, T.
    Akiba, M.
    Izumiyama, S.
    Yagita, K.
    Endo, T.
    WATER SCIENCE AND TECHNOLOGY, 2009, 60 (08) : 2167 - 2172
  • [46] Specific detection of reverse transcription-loop-mediated isothermal amplification amplicons for Taura syndrome virus by colorimetric dot-blot hybridization
    Teng, Ping-Hua
    Chen, Chu-Liang
    Sung, Ping-Feng
    Lee, Fu-Chun
    Ou, Bor-Rung
    Lee, Pei-Yu
    JOURNAL OF VIROLOGICAL METHODS, 2007, 146 (1-2) : 317 - 326
  • [47] Development and evaluation of reverse transcription-loop-mediated isothermal amplification assay for rapid and real-time detection of Japanese encephalitis virus
    Parida, M. M.
    Santhosh, S. R.
    Dash, P. K.
    Tripathi, N. K.
    Saxena, P.
    Ambuj, S.
    Sahni, A. K.
    Rao, P. V. Lakshmana
    Morita, Kouichi
    JOURNAL OF CLINICAL MICROBIOLOGY, 2006, 44 (11) : 4172 - 4178
  • [48] A Rapid and Sensitive Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for the Detection of Indian Citrus Ringspot Virus
    Kokane, Amol D.
    Kokane, Sunil B.
    Warghane, Ashish J.
    Gubyad, Mrugendra G.
    Sharma, Ashwani Kumar
    Reddy, M. Krishna
    Ghosh, Dilip Kumar
    PLANT DISEASE, 2021, 105 (05) : 1346 - 1355
  • [49] Development of Reverse Transcription-Loop-Mediated Isothermal Amplification (RT-LAMP) Assay for Detection of Avian Influenza Viruses in Field Specimens
    Shivakoti, Sakar
    Ito, Hiroshi
    Murase, Toshiyuki
    Ono, Etsuro
    Takakuwa, Hiroki
    Yamashiro, Tetsu
    Otsuki, Koichi
    Ito, Toshihiro
    JOURNAL OF VETERINARY MEDICAL SCIENCE, 2010, 72 (04): : 519 - 523
  • [50] Development of a reverse transcription-loop-mediated isothermal amplification as a rapid early-detection method for novel SARS-CoV-2
    Baek, Yun Hee
    Um, Jihye
    Antigua, Khristine Joy C.
    Park, Ji-Hyun
    Kim, Yeonjae
    Oh, Sol
    Kim, Young-il
    Choi, Won-Suk
    Kim, Seong Gyu
    Jeong, Ju Hwan
    Chin, Bum Sik
    Nicolas, Halcyon Dawn G.
    Ahn, Ji-Young
    Shin, Kyeong Seob
    Choi, Young Ki
    Park, Jun-Sun
    Song, Min-Suk
    EMERGING MICROBES & INFECTIONS, 2020, 9 (01) : 998 - 1007