3-D Imaging using Row-Column-Addressed 2-D Arrays with a Diverging Lens

被引:0
|
作者
Bouzari, Hamed [1 ]
Engholm, Mathias [2 ]
Stuart, Matthias Bo [1 ]
Nikolov, Svetoslav Ivanov [3 ]
Thomsen, Erik Vilain [2 ]
Jensen, Jorgen Arendt [1 ]
机构
[1] Tech Univ Denmark, Dept Elect Engn, Ctr Fast Ultrasound Imaging, Bldg 349, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Micro & Nanotechnol, DK-2800 Lyngby, Denmark
[3] BK Ultrasound ApS, Herlev, Denmark
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
It has been shown that row-column-addressed (RCA) 2-D arrays can be an inexpensive alternative to fully addressed 2-D arrays. Generally imaging with an RCA 2-D array is limited to its forward-looking volume region. Constructing a double-curved RCA 2-D array or applying a diverging lens over the flat RCA 2-D array, can extend the imaging field-of-view (FOV) to a curvilinear volume without increasing the aperture size, which is necessary for applications such as abdominal and cardiac imaging. Extended FOV and low channel count of double-curved RCA 2-D arrays make it possible to have 3-D imaging with equipment in the price range of conventional 2-D imaging. This study proposes a delay-and-sum (DAS) beamformation scheme specific to double-curved RCA 2-D arrays and validates its focusing ability based on simulations. A synthetic aperture imaging (SAI) sequence with single element transmissions at a time, is designed for imaging down to 14 cm at a volume rate of 88 Hz. The curvilinear imaging performance of a lambda/2-pitch 3MHz 62+62 RCA 2-D array is investigated as a function of depth, using a diverging lens with f-number of -1. The results of this study demonstrate that the proposed beamforming approach is accurate for achieving correct time-of-flight calculations, and hence avoids geometrical distortions.
引用
收藏
页数:4
相关论文
共 50 条
  • [41] 2-D army for 3-D ultrasound imaging using synthetic aperture techniques
    Daher, NM
    Yen, JT
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2006, 53 (05) : 912 - 924
  • [42] 3-D Radar Imaging Using Extended 2-D Range Migration Technique
    Nagarad, Rohan S.
    Sourabh, A. S.
    Acharya, U. Sripathi
    Srihari, Pathipati
    Prasad, S.
    Rao, P. H.
    [J]. 2017 IEEE APPLIED ELECTROMAGNETICS CONFERENCE (AEMC), 2017,
  • [43] Row-Column-Based Coherence Imaging Using a 2-D Array Transducer: A Row-Based Implementation
    Fatemi, Ali
    Masoy, Svein-Erik
    Rodriguez-Molares, Alfonso
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (11) : 2303 - 2311
  • [44] 3-D Spatial Compounding Using a Row-Column Array
    Awad, Samer I.
    Yen, Jesse T.
    [J]. ULTRASONIC IMAGING, 2009, 31 (02) : 120 - 130
  • [45] MORPHING IN 2-D AND 3-D
    HALL, V
    [J]. DR DOBBS JOURNAL, 1993, 18 (07): : 18 - 20
  • [46] Ocean Sensor "Imaging" Arrays Based on Bio-inspired Architectures and 2-D/3-D Construction
    Fries, David P.
    Starr, Chase A.
    Barton, Geran W.
    [J]. MARINE TECHNOLOGY SOCIETY JOURNAL, 2015, 49 (03) : 43 - 49
  • [47] 2-D Row-Column CMUT Arrays with an Open-Grid Support Structure
    Christiansen, Thomas Lehrmann
    Dahl-Petersen, Christian
    Jensen, Jorgen Arendt
    Thomsen, Erik V.
    [J]. 2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1712 - 1715
  • [48] 3-D Object Recognition Using 2-D Views
    Li, Wenjing
    Bebis, George
    Bourbakis, Nikolaos G.
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2008, 17 (11) : 2236 - 2255
  • [49] 3-D acoustic homing using 2-D asymptotes
    Arunkumar, G. K.
    Vachhani, Leena
    [J]. MECHATRONICS, 2020, 70
  • [50] A Low-Cost 3-D Imaging Device Using 2-D LiDAR and Reflectors
    Yan, Bo
    Wang, Wenxuan
    Yan, Ying
    Xu, Luping
    Zhang, Hua
    [J]. IEEE SENSORS JOURNAL, 2023, 23 (08) : 8797 - 8809