摘要
We investigated the nature of the mechanical and the electrical tip-sample contact in scanning conductive torsion mode microscopy (SCTMM). Experiments on the soft conducting polymer blend of poly(3,4-ethylenedioxythiophene) poly(styrenesulfonate) demonstrated that the tip-sample force and thus the danger of tip-induced sample damage can be minimized. Using current-voltage spectroscopy, we found a space-charge limited conduction behavior with no indication of a tunneling barrier. Spectroscopy and imaging experiments showed that SCTMM allows for a gentler tip-sample contact compared to conventional conductive scanning force microscopy. A gentle and well-defined contact is a prerequisite for reproducible scanning probe based conductivity measurements, in particular on soft organic materials. (C) 2013 AIP Publishing LLC [http://dx.doi.org/10.1063/1.4802725]
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Nature of tip-sample interaction in dynamic mode atomic force microscopy
    Univ of Tokyo, Tokyo, Japan
    Jpn J Appl Phys Part 1 Regul Pap Short Note Rev Pap, 12 A (7354-7557):
  • [22] Analysis of tip-sample interaction in tapping-mode atomic force microscope using an electrical circuit simulator
    Sahin, O
    Atalar, A
    APPLIED PHYSICS LETTERS, 2001, 78 (19) : 2973 - 2975
  • [23] Nature of tip-sample interaction in dynamic mode atomic force microscopy
    Kageshima, M
    Imayoshi, T
    Yamada, H
    Nakayama, K
    Sakama, H
    Kawazu, A
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1997, 36 (12A): : 7354 - 7357
  • [24] Tip-sample relaxation as a source of uncertainty in nanoscale scanning probe microscopy measurements
    Campbellova, Anna
    Klapetek, Petr
    Valtr, Miroslav
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (08)
  • [25] Quantifying non-contact tip-sample thermal exchange parameters for accurate scanning thermal microscopy with heated microprobes
    Wilson, Adam A.
    Borca-Tasciuc, Theodorian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (07):
  • [26] Effects of tip-sample forces and humidity on the imaging of DNA with a scanning force microscope
    Yang, GL
    Vesenka, JP
    Bustamante, CJ
    SCANNING, 1996, 18 (05) : 344 - 350
  • [27] Tip-sample distance control for near-field scanning microwave microscopes
    Kim, MS
    Kim, S
    Kim, J
    Lee, K
    Friedman, B
    Kim, JT
    Lee, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (08): : 3675 - 3678
  • [28] AC scanning thermal microscopy:: Tip-sample interaction and buried defects modellings
    Gomès, S
    Trannoy, N
    Depasse, F
    Grossel, P
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2000, 39 (04) : 526 - 531
  • [29] Gap dependence of the tip-sample capacitance
    Kurokawa, S
    Sakai, A
    JOURNAL OF APPLIED PHYSICS, 1998, 83 (12) : 7416 - 7423
  • [30] The tip-sample water bridge and light emission from scanning tunnelling microscopy
    Boyle, Michael G.
    Mitra, J.
    Dawson, Paul
    NANOTECHNOLOGY, 2009, 20 (33)