Quantification of Artifacts in MR Images Caused by Commonly Used Dental Materials

被引:2
|
作者
Valizadeh, Solmaz [1 ]
Pouraliakbar, Hamidreza [2 ]
Arzani, Vida [1 ]
Nahardani, Ali [3 ]
机构
[1] Shahid Beheshti Univ Med Sci, Sch Dent, Dept Radiol, Tehran, Iran
[2] Iran Univ Med Sci, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[3] Shahid Beheshti Univ Med Sci, Sch Allied Med Sci, Tehran, Iran
关键词
Magnetic Resonance Imaging; Dental Materials; Artifact; MAGNETIC-RESONANCE IMAGES; ORTHODONTIC APPLIANCES; IMAGING ARTIFACTS; SUSCEPTIBILITY; OBJECTS; JOINT;
D O I
10.5812/iranjradiol.55566
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Although new approaches for application of magnetic resonance imaging (MRI) in dentistry have been promising, the presence of dental materials in the oral cavity represents a major obstacle to generating quality MRI data. The resulting artifacts can adversely affect diagnostic accuracy of oral and maxillofacial conditions. Objectives: This study aimed to detect and assess artifacts caused by metallic and non-metallic dental materials in MR images. Materials and Methods: Nineteen commonly used dental materials were used in an in vitro assay. An empty cube-shaped phantom with internal dimensions of 15 x 15 x 15 cm(3) was fabricated of polyester and filled with paraffin or distilled water to create optimal contrast for T1-weighted (T1W; for anatomical structures), T2-weighted (T2W, for pathological conditions) and proton density-weighted (PDW) MR images. Dental material samples were manufactured and placed at the center of the mold using polyester tubes. All samples were then subjected to MRI using two-dimensional (2D) and three-dimensional (3D) T1W, T2W and PDW imaging sequences. The data were subjected to one-way analysis of variance (ANOVA) followed by mean comparison using the Tukey's test. Results: Comparison of mean artifact size in 2D and 3D images showed that ceramic caused the smallest (189.48 mm(3)) and orthodontic metal brackets caused the largest (4307.5 mm(3)) artifact areas. Assessment of the amount of artifacts created in different imaging sequences revealed minimal artifact in inversion recovery sequence and maximum artifact in gradient echo sequence of the amount of artifacts at different weighing times in 2D and 3D images showed minimal artifacts in PDW and maximum artifacts in T2W. Conclusion: Bracket, titanium implants, and the nickel-chromium (Ni-Cr) materials are the three most susceptible materials to external B0 magnetic field; thus creating huge metal-induced artifacts. The Siemens default two dimensional turbo spin echo (2D-TSE), 2D-BLADE, three dimensional volumetric interpolated breath-hold examination (3D-VIBE) and three dimensional sampling perfection with application optimized contrasts using different flip angle evolution (3D-SPACE) are the most appropriate pulse sequences for the 2D-T1W, 2D-T2W, 3D-T1W, and 3D-T2W evaluations of the bracket/titanium/Ni-Cr materials, respectively. The rest of the materials' magnetic susceptibility effects are negligible, and artifacts are small.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Evaluation of MRI artifacts at 3 Tesla for 38 commonly used cosmetics
    Escher, Kirin
    Shellock, Frank G.
    MAGNETIC RESONANCE IMAGING, 2013, 31 (05) : 778 - 782
  • [22] Quantification of delayed enhancement MR images
    Dikici, E
    O'Donnell, T
    Setser, R
    White, RD
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2004, PT 1, PROCEEDINGS, 2004, 3216 : 250 - 257
  • [23] Artifacts on CT and MR images and the diagnostic pitfalls in neuroimaging
    Woronoff, AJ
    Boyko, OB
    Crawford, CR
    Akhtar, N
    Kochan, JP
    RADIOLOGY, 1996, 201 : 90 - 90
  • [24] Correction of Artifacts in Diffusion-Weighted MR Images
    Marcon, Petr
    Bartusek, Karel
    Korinek, Radim
    Dokoupil, Zdenek
    2011 34TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2011, : 391 - 397
  • [25] Elimination of magnetic field foldover artifacts in MR images
    Larkman, DJ
    Herlihy, AH
    Coutts, GA
    Hajnal, JV
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2000, 12 (05) : 795 - 797
  • [26] COMMONLY USED SUTURE MATERIALS IN SKIN SURGERY
    MOY, RL
    LEE, A
    ZALKA, A
    AMERICAN FAMILY PHYSICIAN, 1991, 44 (06) : 2123 - 2128
  • [27] Quantification and minimization of magnetic susceptibility artifacts on GRE images
    Port, JD
    Pomper, MG
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (06) : 958 - 964
  • [28] TISSUE NECROSIS CAUSED BY COMMONLY USED INTRAVENOUS INFUSIONS
    GAZE, NR
    LANCET, 1978, 2 (8086): : 417 - 419
  • [29] ANNEALING PROCEDURES FOR COMMONLY USED RADIOTHERMOLUMINESCENT MATERIALS
    DRISCOLL, CMH
    BARTHE, JR
    OBERHOFER, M
    BUSUOLI, G
    HICKMAN, C
    RADIATION PROTECTION DOSIMETRY, 1986, 14 (01) : 17 - 32
  • [30] Hysteresis errors of commonly used sensor materials
    Aydemir, Bulent
    Yagmur, Levent
    Fank, Sinan
    MEASUREMENT, 2010, 43 (06) : 792 - 796