Elimination of magnetic field foldover artifacts in MR images

被引:1
|
作者
Larkman, DJ [1 ]
Herlihy, AH [1 ]
Coutts, GA [1 ]
Hajnal, JV [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Sch Med, Robert Steiner MRI Unit, Hammersmith Hosp, London W12 0HS, England
关键词
foldover artifact; cusp artifact; short bore;
D O I
10.1002/1522-2586(200011)12:5<795::AID-JMRI20>3.0.CO;2-H
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Foldover artifacts arise when the same imaging frequency occurs both at a desired location within a slice and at another location within the sensitive region of the radiofrequency (RF) coil. Foldover artifacts can be caused by nonlinearity in the gradient system and by inhomogeneity in Bo. This study investigates an approach in which an extra RF receiver coil and a postprocessing method are used to identify and remove foldover artifacts. (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:795 / 797
页数:3
相关论文
共 50 条
  • [1] DENTAL MATERIAL ARTIFACTS ON MR IMAGES
    HINSHAW, DB
    HOLSHOUSER, BA
    ENGSTROM, HIM
    TJAN, AHL
    CHRISTIANSEN, EL
    CATELLI, WF
    RADIOLOGY, 1988, 166 (03) : 777 - 779
  • [2] Suppression of vascular artifacts in functional magnetic resonance images using MR angiograms
    Hlustik, P
    Noll, DC
    Small, SL
    NEUROIMAGE, 1998, 7 (03) : 224 - 231
  • [3] A novel strategy for segmentation of magnetic resonance (MR) images corrupted by intensity inhomogeneity artifacts
    Chen, Weijie
    Giger, Maryellen L.
    MEDICAL IMAGING 2006: IMAGE PROCESSING, PTS 1-3, 2006, 6144
  • [4] ARTIFACTS ON MAGNETIC-RESONANCE IMAGES
    SOLOMON, MA
    SWEENEY, JP
    SHELDON, PE
    STUBBS, K
    PREVOST, LP
    SKELTON, C
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1985, 6 (03) : 471 - 471
  • [5] MR-SRNET: TRANSFORMATION OF LOW FIELD MR IMAGES TO HIGH FIELD MR IMAGES
    Kaur, Prabhjot
    Sharma, Aditya
    Nigam, Aditya
    Bhavsar, Arnav
    2018 25TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2018, : 2057 - 2061
  • [6] Artifacts on CT and MR images and the diagnostic pitfalls in neuroimaging
    Woronoff, AJ
    Boyko, OB
    Crawford, CR
    Akhtar, N
    Kochan, JP
    RADIOLOGY, 1996, 201 : 90 - 90
  • [7] Correction of Artifacts in Diffusion-Weighted MR Images
    Marcon, Petr
    Bartusek, Karel
    Korinek, Radim
    Dokoupil, Zdenek
    2011 34TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2011, : 391 - 397
  • [8] A Study of Grid Artifacts Formation and Elimination in Computed Radiographic Images
    Chih-Yang Lin
    Wen-Jeng Lee
    Shyh-Jye Chen
    Ching-Hwa Tsai
    Jei-Han Lee
    Chia-Hung Chang
    Yu-Tai Ching
    Journal of Digital Imaging, 2006, 19 : 351 - 361
  • [9] A study of grid artifacts formation and elimination in computed radiographic images
    Lin, Chih-Yang
    Lee, Wen-Jeng
    Chen, Shyh-Jye
    Tsai, Ching-Hwa
    Lee, Jei-Han
    Chang, Chia-Hung
    Ching, Yu-Tai
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (04) : 351 - 361
  • [10] Elimination of periodic damped artifacts in scanning probe microscopy images
    Chen, Yuhang
    Huang, Wenhao