Implementation of a nanochannel open/close valve into a glass nanofluidic device

被引:10
|
作者
Sano, Hiroki [1 ]
Kazoe, Yutaka [2 ]
Morikawa, Kyojiro [3 ]
Kitamori, Takehiko [3 ,4 ]
机构
[1] Univ Tokyo, Dept Appl Chem, Sch Engn, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[2] Keio Univ, Dept Syst Design Engn, Fac Sci & Technol, 3-14-1 Hiyoshi, Yokohama, Kanagawa 2238522, Japan
[3] Univ Tokyo, Collaborat Res Org Micro & Nano Multifunct Device, Bunkyo Ku, 7-3-1 Hongo, Tokyo 1138656, Japan
[4] Natl Tsing Hua Univ, Inst Nanoengn & Microsyst, Dept Power Mech Engn, 101,Sect 2,Kuang Fu Rd, Hsinchu 30013, Taiwan
基金
日本科学技术振兴机构;
关键词
Nanofluidics; Nanochannel; Valve; Femtoliter; Fluidic operation; LIQUID PROPERTIES; MICROCHIP;
D O I
10.1007/s10404-020-02383-x
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
In micro-/nanofluidics, channel open/close valves are fundamental to integrating fluid operations and realizing highly integrated analytical devices. Recently, we proposed a nanochannel open/close valve utilizing glass deformation and verified the principle of opening and closing nanochannels. Glass deformation sufficient to close the valve was achieved using a 45-mu m-thick glass sheet as a material of a nanofluidic device. However, since the device incorporates the thin glass sheet and is not robust enough to be used for repeated analyses, fluid operations utilizing the valve have not been verified sufficiently. Thus, in the present study, we fabricated a nanofluidic device implemented with a nanochannel open/close valve using rigid glass substrates of thicknesses on the order of 100 mu m, and verified fluid operations utilizing the valve. On a small part of the substrate, we designed and fabricated a 30-mu m-thick deformation section for the valve. The open/close operation and the performance of the valve were verified. The leakage of the valve was measured to be 2%, the response time was 0.9 s, and the number of repetitions was over 100,000. By utilizing the fabricated valve, we demonstrated fluid operations with femtoliter to picoliter volumes. Flow-switching within approximately 1 s and a flow control rate in the 63-1341 fL/s range was achieved. In addition, the fluid resistance of the valve was investigated both experimentally and numerically to establish a guideline for designing the valve. The valve developed and the design guidelines obtained will greatly contribute to integrated nanofluidic analytical devices.
引用
收藏
页数:11
相关论文
共 38 条
  • [1] Implementation of a nanochannel open/close valve into a glass nanofluidic device
    Hiroki Sano
    Yutaka Kazoe
    Kyojiro Morikawa
    Takehiko Kitamori
    [J]. Microfluidics and Nanofluidics, 2020, 24
  • [2] Nanofluidic gas/liquid switching utilizing a nanochannel open/close valve based on glass deformation
    Sano, Hiroki
    Kazoe, Yutaka
    Morikawa, Kyojiro
    Kitamori, Takehiko
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2023, 33 (08)
  • [3] Nanofluidic analytical system integrated with nanochannel open/close valves for enzyme-linked immunosorbent assay
    Sano, Hiroki
    Kazoe, Yutaka
    Ohta, Ryoichi
    Shimizu, Hisashi
    Morikawa, Kyojiro
    Kitamori, Takehiko
    [J]. LAB ON A CHIP, 2023, 23 (04) : 727 - 736
  • [4] Picoliter liquid operations in nanofluidic channel utilizing an open/close valve with nanoscale curved structure mimicking glass deflection
    Sano, Hiroki
    Kazoe, Yutaka
    Morikawa, Kyojiro
    Kitamori, Takehiko
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 2022, 32 (05)
  • [5] Detachable glass micro/nanofluidic device
    Ohta, Ryoichi
    Mawatari, Kazuma
    Takeuchi, Tomoaki
    Morikawa, Kyojiro
    Kitamori, Takehiko
    [J]. BIOMICROFLUIDICS, 2019, 13 (02)
  • [6] Femtoliter nanofluidic valve utilizing glass deformation
    Kazoe, Yutaka
    Pihosh, Yuriy
    Takahashi, Hitomi
    Ohyama, Takeshi
    Sano, Hiroki
    Morikawa, Kyojiro
    Mawatari, Kazuma
    Kitamori, Takehiko
    [J]. LAB ON A CHIP, 2019, 19 (09) : 1686 - 1694
  • [7] An Integrated Glass Nanofluidic Device Enabling In-situ Electrokinetic Probing of Water Confined in a Single Nanochannel under Pressure-Driven Flow Conditions
    Xu, Yan
    Xu, Baihui
    [J]. SMALL, 2015, 11 (46) : 6165 - 6171
  • [8] Glass-based nanofluidic device for biomolecule preconcentration study
    Svarnas, P.
    Plecis, A.
    Nanteuil, C.
    Duong, D.
    David, C.
    Muller, M.
    Chen, Y.
    [J]. EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 2008, 44 (03): : 245 - 253
  • [9] On the implementation and effectiveness of morphological close-open and open-close filters for topology optimization
    Schevenels, Mattias
    Sigmund, Ole
    [J]. STRUCTURAL AND MULTIDISCIPLINARY OPTIMIZATION, 2016, 54 (01) : 15 - 21
  • [10] On the implementation and effectiveness of morphological close-open and open-close filters for topology optimization
    Mattias Schevenels
    Ole Sigmund
    [J]. Structural and Multidisciplinary Optimization, 2016, 54 : 15 - 21