Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

被引:68
|
作者
Verberk, Willem J. [1 ,2 ]
Omboni, Stefano [3 ]
Kollias, Anastasios [4 ]
Stergiou, George S. [4 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, NL-6200 MD Maastricht, Netherlands
[2] Microlife AG, Widnau, Switzerland
[3] Italian Inst Telemed, Clin Res Unit, Varese, Italy
[4] Sotiria Hosp, Univ Dept Med 3, Hypertens Ctr STRIDE 7, Athens, Greece
关键词
Arrhythmia; Blood pressure monitoring; Self-measurement; Home blood pressure; Clinic; Stroke; CRYPTOGENIC STROKE; EUROPEAN-SOCIETY; PRIMARY-CARE; RISK-FACTORS; PREVALENCE; MANAGEMENT; ACCURACY; PREVENTION; GUIDELINES; MONITORS;
D O I
10.1016/j.ijcard.2015.10.182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged >= 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects >= 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [31] Automated blood pressure measurement in patients with chronic atrial fibrillation: Which is the most reliable and accurate type of blood pressure measuring device?
    Eckert, S
    Gleichmann, U
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1996, 25 (08) : 346 - 348
  • [32] Unattended automated office blood pressure measurement - current evidence and the role in clinical practice
    Stopa, Marek
    Olszanecka, Agnieszka
    Rajzer, Marek
    ARTERIAL HYPERTENSION, 2021, 25 (03): : 100 - 105
  • [33] Correction: Blood pressure measurement in atrial fibrillation: goodbye mercury?
    T. Watson
    G. Y. H. Lip
    Journal of Human Hypertension, 2021, 35 : 107 - 107
  • [34] Automated blood pressure measurement in routine clinical practice
    Myers, MG
    BLOOD PRESSURE MONITORING, 2006, 11 (02) : 59 - 62
  • [35] Diagnostic Performance of Automated Blood Pressure Monitor for Detection of Atrial Fibrillation
    Othman, Rasid
    Suliman, Ayman
    Yusof, Zurkurnai
    Isa, W. Yus Haniff W.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [36] Automated Versus Manual Blood Pressure in Patients With Atrial Fibrillation and/or Hypertension
    Pouliot, Jo Anne
    Moravec, Jennie
    JOURNAL OF CARDIOVASCULAR NURSING, 2016, 31 (06) : 486 - 487
  • [37] Screening For Atrial Fibrillation In General Practice
    Flannery, B.
    Rizvi, S.
    Long, K.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2018, 187 : S66 - S66
  • [38] Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening
    Li, Linyi
    Bing, Sen
    Liu, Kui
    Jiang, Jun
    Zhang, Jieqiong
    Chen, Changsheng
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2023, 28 (03) : 144 - 148
  • [39] Blood pressure measurement in atrial fibrillation: review and meta-analysis of evidence on accuracy and clinical relevance
    Stergiou, George S.
    Kyriakoulis, Konstantinos G.
    Stambolliu, Emelina
    Destounis, Antonios
    Karpettas, Nikos
    Kalogeropoulos, Petros
    Kollias, Anastasios
    JOURNAL OF HYPERTENSION, 2019, 37 (12) : 2430 - 2441
  • [40] Ambulatory Blood Pressure Measurement in the Elderly An Opportunity to Screen for Atrial Fibrillation
    O'Brien, Eoin
    Dolan, Eamon
    HYPERTENSION, 2019, 73 (05) : 961 - 964