Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

被引:68
|
作者
Verberk, Willem J. [1 ,2 ]
Omboni, Stefano [3 ]
Kollias, Anastasios [4 ]
Stergiou, George S. [4 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, NL-6200 MD Maastricht, Netherlands
[2] Microlife AG, Widnau, Switzerland
[3] Italian Inst Telemed, Clin Res Unit, Varese, Italy
[4] Sotiria Hosp, Univ Dept Med 3, Hypertens Ctr STRIDE 7, Athens, Greece
关键词
Arrhythmia; Blood pressure monitoring; Self-measurement; Home blood pressure; Clinic; Stroke; CRYPTOGENIC STROKE; EUROPEAN-SOCIETY; PRIMARY-CARE; RISK-FACTORS; PREVALENCE; MANAGEMENT; ACCURACY; PREVENTION; GUIDELINES; MONITORS;
D O I
10.1016/j.ijcard.2015.10.182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged >= 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects >= 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [21] Accuracy of oscillometric blood pressure measurement in atrial fibrillation
    Feenstra, Rudolf K.
    Allaart, Cor P.
    Berkelmans, Gijs F. N.
    Westerhof, Berend E.
    Smulders, Yvo M.
    BLOOD PRESSURE MONITORING, 2018, 23 (02) : 59 - 63
  • [22] Blood pressure measurement in atrial fibrillation: goodbye mercury?
    Watson, T.
    Lip, G. Y. H.
    JOURNAL OF HUMAN HYPERTENSION, 2006, 20 (09) : 638 - 640
  • [23] Correction: Measurement of blood pressure in people with atrial fibrillation
    Christopher E. Clark
    Sinead T. J. McDonagh
    Richard J. McManus
    Journal of Human Hypertension, 2020, 34 : 476 - 476
  • [24] Targeted screening of atrial fibrillation using automated blood pressure measurement device with atrial fibrillation detection function, in patients with type 2 diabetes mellitus in primary care setting
    Yu Man Wong
    Pang Fai Chan
    Kit Ping Loretta Lai
    Man Hei Matthew Luk
    Hoi Tik Fung
    Sze Wai Yeung
    International Journal of Arrhythmia, 25 (1)
  • [25] Blood pressure measurement: Gaps between recommendations and practice
    Pauline, M
    Vaz, M
    NATIONAL MEDICAL JOURNAL OF INDIA, 2005, 18 (06): : 330 - 330
  • [26] Leg blood pressure measurement: utility, pitfalls & recommendations for clinical practice and future research
    Obeid, Amira
    Pucci, Mark
    Martin, Una
    JOURNAL OF HUMAN HYPERTENSION, 2015, 29 (10) : 634 - 634
  • [27] Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements
    Lowe, Andrew
    Oh, Timothy H.
    Stewart, Ralph
    IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE, 2018, 6
  • [28] ATRIAL FIBRILLATION DETECTION DURING AUTOMATED BLOOD PRESSURE MEASUREMENT: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Kyriakoulis, K.
    Kollias, A.
    Stambolliu, E.
    Stergiou, G. S.
    JOURNAL OF HYPERTENSION, 2018, 36 : E60 - E60
  • [29] Accuracy of automated blood pressure measurement in the presence of atrial fibrillation: systematic review and meta-analysis
    McDonagh, Sinead
    McManus, Richard
    Clark, Christopher
    JOURNAL OF HUMAN HYPERTENSION, 2018, 32 (10) : 706 - 706
  • [30] Automated blood pressure measurement in special situations: Patients with chronic atrial fibrillation or chronic aortic regurgitation
    Eckert, S
    Gleichmann, S
    Gleichmann, U
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 92 - 98