Screening for atrial fibrillation with automated blood pressure measurement: Research evidence and practice recommendations

被引:68
|
作者
Verberk, Willem J. [1 ,2 ]
Omboni, Stefano [3 ]
Kollias, Anastasios [4 ]
Stergiou, George S. [4 ]
机构
[1] Maastricht Univ, Cardiovasc Res Inst Maastricht CARIM, NL-6200 MD Maastricht, Netherlands
[2] Microlife AG, Widnau, Switzerland
[3] Italian Inst Telemed, Clin Res Unit, Varese, Italy
[4] Sotiria Hosp, Univ Dept Med 3, Hypertens Ctr STRIDE 7, Athens, Greece
关键词
Arrhythmia; Blood pressure monitoring; Self-measurement; Home blood pressure; Clinic; Stroke; CRYPTOGENIC STROKE; EUROPEAN-SOCIETY; PRIMARY-CARE; RISK-FACTORS; PREVALENCE; MANAGEMENT; ACCURACY; PREVENTION; GUIDELINES; MONITORS;
D O I
10.1016/j.ijcard.2015.10.182
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Several guidelines recommend opportunistic screening for atrial fibrillation (AF) in subjects aged >= 65 years using pulse palpation during routine blood pressure (BP) measurement. However, this method has limited diagnostic accuracy. A specific algorithm for AF detection during automated BP measurement was developed and implemented in a novel oscillometric device (Microlife WatchBP Home-A). In 2013, the UK National Institute for Health and Care Excellence (NICE) recommended this device for AF screening during routine office BP measurement in primary care in subjects >= 65 years. A review and meta-analysis of the evidence on the diagnostic accuracy of this algorithm were performed. Six studies (n=2332) investigated the accuracy of AF detection using the Microlife BP monitor and estimated a pooled sensitivity at 0.98 (95% CI 0.95, 1.00) and specificity 0.92 (0.88, 0.96). Analysis of 4 studies (n=1126) showed more readings to improve specificity (from 0.86 to 0.91) and sensitivity (from 0.97 to 0.99). Taking 3 sequential readings with at least 2 detecting AF gave the highest diagnostic accuracy. A single study (n=139) of paroxysmal AF screening with home BP monitoring (3316 days) showed sensitivity 99% and specificity 93%. Another study (n = 46) of AF screening with 24 h ambulatory BP monitoring showed that AF detected in >15% of all readings has high probability of AF diagnosis requiring confirmation by 24 h electrocardiography. AF detection with routine automated BP measurement is a reliable screening tool in the elderly, which requires confirmation by electrocardiography. Paroxysmal AF might also be detected by routine automated home or ambulatory BP monitoring. (C) 2015 The Authors. Published by Elsevier Ireland Ltd.
引用
收藏
页码:465 / 473
页数:9
相关论文
共 50 条
  • [1] Does Atrial Fibrillation Affect the Automated Oscillometric Blood Pressure Measurement?
    Stergiou, George S.
    Kollias, Anastasios
    Karpettas, Nikos
    HYPERTENSION, 2013, 62 (05) : E37 - E37
  • [2] Automated measurement of office, home and ambulatory blood pressure in atrial fibrillation
    Kollias, Anastasios
    Stergiou, George S.
    CLINICAL AND EXPERIMENTAL PHARMACOLOGY AND PHYSIOLOGY, 2014, 41 (01) : 9 - 15
  • [3] Opportunistic screening of atrial fibrillation by automatic blood pressure measurement in the community
    Omboni, Stefano
    Verberk, Willem J.
    BMJ OPEN, 2016, 6 (04):
  • [4] Screening for atrial fibrillation during automated blood pressure measurement among patients admitted to internal medicine ward
    Pucci, Giacomo
    Santoni, Edoardo
    Bisogni, Valeria
    Calandri, Camilla
    Cerasari, Alberto
    Dominioni, Irene
    Sanesi, Leandro
    D'Abbondanza, Marco
    Veca, Vito
    Vaudo, Gaetano
    INTERNAL AND EMERGENCY MEDICINE, 2021, 16 (06) : 1605 - 1611
  • [5] Screening for atrial fibrillation during automated blood pressure measurement among patients admitted to internal medicine ward
    Giacomo Pucci
    Edoardo Santoni
    Valeria Bisogni
    Camilla Calandri
    Alberto Cerasari
    Irene Dominioni
    Leandro Sanesi
    Marco D’Abbondanza
    Vito Veca
    Gaetano Vaudo
    Internal and Emergency Medicine, 2021, 16 : 1605 - 1611
  • [6] SCREENING FOR ATRIAL FIBRILLATION WITH ROUTINE AUTOMATED BLOOD PRESSURE MEASUREMENT IN THE ELDERLY: THE NATIONAL HEALTH SURVEY EMENO IN GREECE
    Stergiou, George S.
    Menti, Ariadni
    Kalpourtzi, Natasa
    Gavana, Magda
    Vantarakis, Apostolos
    Chlouverakis, Gregory
    Hadjichristodoulou, Christos
    Trypsianis, Gregory
    Voulgari, Paraskevi
    Alamanos, Yannis
    Karakosta, Argiro
    Touloumi, Giota
    JOURNAL OF HYPERTENSION, 2022, 40 (SUPPL) : E14 - E15
  • [7] Response to Does Atrial Fibrillation Affect the Automated Oscillometric Blood Pressure Measurement?
    Pagonas, Nikolaos
    Westhoff, Timm H.
    HYPERTENSION, 2013, 62 (05) : E38 - E38
  • [8] Atrial fibrillation screening during automated blood pressure measurementComment on "Diagnostic accuracy of new algorithm to detect atrial fibrillation in a home blood pressure monitor"
    Chen, Yi
    Lei, Lei
    Wang, Ji-Guang
    JOURNAL OF CLINICAL HYPERTENSION, 2017, 19 (11): : 1148 - 1151
  • [9] AUTOMATED BLOOD PRESSURE MEASUREMENT IN PATIENTS WITH HYPERTENSION AND ATRIAL FIBRILLATION. DATA FROM THE ESH RESEARCH PROJECT "MANAGEMENT OF ARTERIAL HYPERTENSION IN PATIENTS WITH HIGH BLOOD PRESSURE AND ATRIAL FIBRILLATION''
    Salvetti, M.
    Jelakovic, B.
    Dorobantu, M.
    Viigimaa, M.
    Manolis, A. J.
    Redon, J.
    Parati, G.
    Rosei, E. Agabiti
    JOURNAL OF HYPERTENSION, 2018, 36 : E29 - E30
  • [10] SIMULTANEOUS BLOOD PRESSURE AND ATRIAL FIBRILLATION SCREENING IN MAY MEASUREMENT MONTH 2022
    Beaney, Thomas
    Kerr, Gabriele
    Schlaich, Markus
    Schutte, Aletta
    Stergiou, George
    Poulter, Neil
    Freedman, Ben
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)