Efficient Reconstruction Technique for Multi-Slice CS-MRI Using Novel Interpolation and 2D Sampling Scheme

被引:9
|
作者
Murad, Maria [1 ]
Bilal, Muhammad [1 ]
Jalil, Abdul [1 ]
Ali, Ahmad [2 ]
Mehmood, Khizer [1 ]
Khan, Baber [1 ]
机构
[1] Int Islamic Univ Islamabad, Dept Elect Engn, Islamabad 44000, Pakistan
[2] Bahria Univ, Dept Software Engn, Islamabad 44000, Pakistan
关键词
Compressed sensing; compressed sensing reconstruction; interpolated compressed sensing; magnetic resonance imaging; multi-slice MRI; nonlinear conjugate gradient; IMAGE-RECONSTRUCTION; SPARSITY;
D O I
10.1109/ACCESS.2020.3004731
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Compressed Sensing (CS) theory breaks the Nyquist theorem through random under-sampling and enables us to reconstruct a signal from 10%-50% samples. Magnetic Resonance Imaging (MRI) is a good candidate for application of compressed sensing techniques due to i) implicit sparsity in MR images and ii) inherently slow data acquisition process. In multi-slice MRI, strong inter-slice correlation has been exploited for further scan time reduction through interpolated compressed sensing (iCS). In this paper, a novel fast interpolated compressed sensing (FiCS) technique is proposed based on 2D variable density under-sampling (VRDU) scheme. The 2D-VRDU scheme improves the result by sampling the high energy central part of the k-space slices. The novel interpolation technique takes two consecutive slices and estimates the missing samples of the target slice (T slice) from its left slice (L slice). Compared to the previous methods, slices recovered with the proposed FiCS technique have a maximum correlation with their corresponding original slices. The proposed FiCS technique is evaluated by using both subjective and objective assessment. In subjective assessment, our proposed technique shows less partial volume loss compared to existing techniques. For objective assessment different performance metrics, such as structural similarity index measurement (SSIM), peak signal to noise ratio (PSNR), mean square error (MSE) and correlation, are used and compared with existing interpolation techniques. Simulation results on knee and brain dataset shows that the proposed FiCS technique has improved image quality and performance with even reduced scan time, lower computational complexity and maximum information content.
引用
收藏
页码:117452 / 117466
页数:15
相关论文
共 50 条
  • [21] Applicability and reproducibility of 2D multi-slice GRASE myelin water fraction with varying acquisition acceleration
    Drenthen, Gerhard S.
    Backes, Walter H.
    Aldenkamp, Albert P.
    Jansen, Jacobus F. A.
    NEUROIMAGE, 2019, 195 : 333 - 339
  • [22] Conservative Management in Three Cases of Prenatally Recognized Splenic Cyst Using 2D, 3D, Multi-Slice and Doppler Ultrasonography
    Dankovcik, Robert
    Urdzik, Peter
    Lazar, Igor
    Gresova, Andrea
    Radonak, Jozef
    Jirasek, Jan E.
    Kucera, Eduard
    Feyereisl, Jaroslav
    Dudas, Marek
    FETAL DIAGNOSIS AND THERAPY, 2009, 26 (03) : 177 - 180
  • [23] A Novel Technique for Estimating Volumetric Cine MRI (VC-MRI) From Multi-Slice Sparsely Sampled Cine Images Using Motion Modeling and Free Form Deformation
    Harris, W.
    Yin, F.
    Wang, C.
    Chang, Z.
    Cai, J.
    Zhang, Y.
    Ren, L.
    MEDICAL PHYSICS, 2016, 43 (06) : 3898 - 3899
  • [24] MR susceptibility contrast imaging using a 2D simultaneous multi-slice gradient-echo sequence at 7T
    Bian, Wei
    Kerr, Adam B.
    Tranvinh, Eric
    Parivash, Sherveen
    Zahneisen, Benjamin
    Han, May H.
    Lock, Christopher B.
    Goubran, Maged
    Zhu, Kongrong
    Rutt, Brian K.
    Zeineh, Michael M.
    PLOS ONE, 2019, 14 (07):
  • [25] Learning the sampling density in 2D SPARKLING MRI acquisition for optimized image reconstruction
    Chaithya, G. R.
    Ramzi, Zaccharie
    Ciuciu, Philippe
    29TH EUROPEAN SIGNAL PROCESSING CONFERENCE (EUSIPCO 2021), 2021, : 960 - 964
  • [26] Design of computationally efficient 2D FIR filters using sampling-kernel-based interpolation and frequency transformation
    Kim, K. J.
    Kim, J. H.
    Nam, S. W.
    ELECTRONICS LETTERS, 2015, 51 (17) : 1326 - 1327
  • [27] Efficient 2D MRI relaxometry using compressed sensing
    Bai, Ruiliang
    Cloninger, Alexander
    Czaja, Wojciech
    Sasser, Peter J.
    JOURNAL OF MAGNETIC RESONANCE, 2015, 255 : 88 - 99
  • [28] Volumetric Cine MRI (VC-MRI) Using Motion Modeling, Free-Form Deformation and Multi-Slice Undersampled 2D Cine MRI Reconstructed with Spatio-Temporal Low-Rank Decomposition
    Harris, W.
    Yin, F.
    Ren, L.
    MEDICAL PHYSICS, 2018, 45 (06) : E645 - E646
  • [29] Efficient representation of 2D contour using non uniform sampling
    Singh, V
    Rajpal, N
    2004 INTERNATIONAL CONFERENCE ON SIGNAL PROCESSING & COMMUNICATIONS (SPCOM), 2004, : 37 - 40
  • [30] Super-Resolution Reconstruction of Multi-Slice T2-W FLAIR MRI Improves Multiple Sclerosis Lesion Segmentation
    Giraldo, Diana L.
    Beirinckx, Quinten
    Den Dekker, Arnold J.
    Jeurissen, Ben
    Sijbers, Jan
    2023 45TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY, EMBC, 2023,