A study on the reproducibility of cephalometric landmarks when undertaking a three-dimensional (3D) cephalometric analysis

被引:48
|
作者
Zamora, Natalia
Llamas, Jose-Maria [1 ]
Cibrian, Rosa [2 ]
Gandia, Jose-Luis [1 ]
Paredes, Vanessa
机构
[1] Univ Valencia, Fac Med & Dent, Dept Orthodont, Postgrad Orthodont Masters Course, Valencia, Spain
[2] Univ Valencia, Fac Med & Dent, Dept Physiol, Valencia, Spain
来源
关键词
Cone Beam Computed Tomography; cephalometry; landmark; orthodontics; reliability; LINEAR ACCURACY; BEAM; IDENTIFICATION; RELIABILITY;
D O I
10.4317/medoral.17721
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: Cone Beam Computerized Tomography (CBCT) allows the possibility of modifying some of the diagnostic tools used in orthodontics, such as cephalometry. The first step must be to study the characteristics of these devices in terms of accuracy and reliability of the most commonly used landmarks. The aims were 1- To assess intra and inter-observer reliability in the location of anatomical landmarks belonging to hard tissues of the skull in images taken with a CBCT device, 2- To determine which of those landmarks are more vs. less reliable and 3- To introduce planes of reference so as to create cephalometric analyses appropriated to the 3D reality. Study design: Fifteen patients who had a CBCT (i-CAT (R)) as a diagnostic register were selected. To assess the reproducibility on landmark location and the differences in the measurements of two observers at different times, 41 landmarks were defined on the three spatial axes (X,Y,Z) and located. 3.690 measurements were taken and, as each determination has 3 coordinates, 11.070 data were processed with SPSS (R) statistical package. To discover the reproducibility of the method on landmark location, an ANOVA was undertaken using two variation factors: time (t1, t2 and t3) and observer (Ob1 and Ob2) for each axis (X, Y and Z) and landmark. The order of the CBCT scans submitted to the observers (Ob1, Ob2) at t1, t2, and t3, were different and randomly allocated. Multiple comparisons were undertaken using the Bonferroni test. The intra- and inter-examiner ICC's were calculated. Results: Intra- and inter- examiner reliability was high, both being ICC >= 0.99, with the best frequency on axis Z. Conclusions: The most reliable landmarks were: Nasion, Sella, Basion, left Porion, point A, anterior nasal spine, Pogonion, Gnathion, Menton, frontozygomatic sutures, first lower molars and upper and lower incisors. Those with less reliability were the supraorbitals, right zygion and posterior nasal spine.
引用
收藏
页码:E678 / E688
页数:11
相关论文
共 50 条
  • [21] Three-dimensional cephalometric superimposition of the nasomaxillary complex
    Lemieux, Genevieve
    Carey, Jason P.
    Flores-Mir, Carlos
    Secanell, Marc
    Hart, Adam
    Dietrich, Nicholas
    Lagravere-Vich, Manuel O.
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2014, 146 (06) : 758 - 764
  • [22] Automatic localization of three-dimensional cephalometric landmarks on CBCT images by extracting symmetry features of the skull
    Neelapu, Bala Chakravarthy
    Kharbanda, Om Prakash
    Sardana, Viren
    Gupta, Abhishek
    Vasamsetti, Srikanth
    Balachandran, Rajiv
    Sardana, Harish Kumar
    DENTOMAXILLOFACIAL RADIOLOGY, 2018, 47 (02)
  • [23] Comparison of the reliability of craniofacial anatomic landmarks based on cephalometric radiographs and three-dimensional CT scans
    Kragskov, J
    Bosch, C
    Gyldensted, C
    SindetPedersen, S
    CLEFT PALATE-CRANIOFACIAL JOURNAL, 1997, 34 (02): : 111 - 116
  • [24] The Reliability of Two- and Three-Dimensional Cephalometric Measurements: A CBCT Study
    Li, Chenshuang
    Teixeira, Hellen
    Tanna, Nipul
    Zheng, Zhong
    Chen, Stephanie Hsiang Yi
    Zou, Min
    Chung, Chun-Hsi
    DIAGNOSTICS, 2021, 11 (12)
  • [25] Reliability of different three-dimensional cephalometric landmarks in cone-beam computed tomography: A systematic review
    Sam, Alycia
    Currie, Kris
    Oh, Heesoo
    Flores-Mir, Carlos
    Lagravere-Vich, Manuel
    ANGLE ORTHODONTIST, 2019, 89 (02) : 317 - 332
  • [26] Accuracy and reliability of automatic three-dimensional cephalometric landmarking
    Dot, G.
    Rafflenbeul, F.
    Arbotto, M.
    Gajny, L.
    Rouch, P.
    Schouman, T.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2020, 49 (10) : 1367 - 1378
  • [27] Computerized three-dimensional cephalometric template for Thai adults
    Duangsuwan, Jeenarat
    Raocharernporn, Somchart
    Thiradilok, Sasipa
    Manopatanakul, Somchai
    HELIYON, 2023, 9 (04)
  • [28] A three-dimensional cephalometric analysis of Japanese adults and its usefulness in orthognathic surgery: A retrospective study
    Yoshikawa, Hiroshi
    Tanikawa, Chihiro
    Ito, Shinsuke
    Tsukiboshi, Yosuke
    Ishii, Hitomi
    Kanomi, Ryuzo
    Yamashiro, Takashi
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2022, 50 (04) : 353 - 363
  • [29] Accuracy of automated 3D cephalometric landmarks by deep learning algorithms: systematic review and meta-analysis
    Serafin, Marco
    Baldini, Benedetta
    Cabitza, Federico
    Carrafiello, Gianpaolo
    Baselli, Giuseppe
    Del Fabbro, Massimo
    Sforza, Chiarella
    Caprioglio, Alberto
    Tartaglia, Gianluca M.
    RADIOLOGIA MEDICA, 2023, 128 (05): : 544 - 555
  • [30] Accuracy of automated 3D cephalometric landmarks by deep learning algorithms: systematic review and meta-analysis
    Marco Serafin
    Benedetta Baldini
    Federico Cabitza
    Gianpaolo Carrafiello
    Giuseppe Baselli
    Massimo Del Fabbro
    Chiarella Sforza
    Alberto Caprioglio
    Gianluca M. Tartaglia
    La radiologia medica, 2023, 128 : 544 - 555