Effect of hemoglobin F and A2 on hemoglobin A1c determined by cation exchange high-performance liquid chromatography

被引:2
|
作者
Can, Murat [1 ]
Guven, Berrak [1 ]
Akca, Ayse Semra Demir [2 ]
机构
[1] Zonguldak Bulent Ecevit Univ, Fac Med, Dept Biochem, TR-67100 Esenkoy, Zonguldak, Turkey
[2] Zonguldak Bulent Ecevit Univ, Fac Med, Dept Family Med, Zonguldak, Turkey
关键词
HbA(1c); HbA(2); HbF; HPLC; hemoglobin variant; immunoassay; INCREASED FETAL-HEMOGLOBIN; ASSAY;
D O I
10.1515/labmed-2019-0040
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background: The potential effect of increase in hemoglobin (Hb) A(2) and HbF on glycated hemoglobin (HbA(1c)) measurements were investigated using a high-performance liquid chromatography (HPLC) method compared with an immunoturbimetric assay. Methods: Samples producing abnormal chromatograms during the measurement of routine HbA(1c) testing with HPLC were further analyzed to characterize abnormal Hb variants. Patients were divided into three groups that had only high HbF (group 1), only high HbA(2) (group 2), and both high HbA(2) and HbF (group 3). A(1c) values of patients were re-assayed using the immunoturbidimetric method (Advia, Siemens Healthcare, Germany). Results: HbA(1c) levels were significantly higher in all groups measured by immunoassay than in HPLC. We found a positive correlation between I IPLC and immunoturbidimetry in the group 2 and a slight correlation in the group 1. There was no correlation between the two methods in group 3. Conclusions: HbA(1c) measurement by HPLC method interfering with elevated HbA(2) and HbF, especially HbF, should be verified by an immunoturbidimetric method.
引用
收藏
页码:265 / 268
页数:4
相关论文
共 50 条
  • [31] DETERMINATION OF CARBAMYLATED HEMOGLOBIN BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KWAN, JTC
    CARR, EC
    BENDING, MR
    BARRON, JL
    CLINICAL CHEMISTRY, 1990, 36 (04) : 607 - 610
  • [32] Interference of Thalassemias on Hemoglobin A1c Measurement by Ion-Exchange High-Performance Liquid Chromatography Method Tosoh HLC-723 G8
    Chao, Yan
    Wan, Zemin
    Wu, Xiaobin
    Qiu, Feng
    Wang, Yunxiu
    Ke, Peifeng
    Wu, Xinzhong
    Xu, Jianhua
    Zhuang, Junhua
    Huang, Xianzhang
    CLINICAL LABORATORY, 2018, 64 (7-8) : 1171 - 1175
  • [33] HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY OF HEMOGLOBINS .1. DETERMINATION OF HEMOGLOBIN-A2
    GOODING, KM
    LU, KC
    REGNIER, FE
    JOURNAL OF CHROMATOGRAPHY, 1979, 164 (04): : 506 - 509
  • [34] The effect of elevated fetal hemoglobin on hemoglobin A1c results
    Rohfing, Curt L.
    Connolly, Shawn M.
    England, Jack D.
    Hanson, Steven E.
    Moellering, Christina M.
    Bachelder, Janielle R.
    Little, Randie R.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2008, 129 (05) : 811 - 814
  • [35] Simultaneous blood donor screening for abnormal hemoglobin levels and glycated hemoglobin (HbA1c) by high-performance liquid chromatography
    Levi, Jose Eduardo
    da Costa Lira, Sanny Marcele
    de Carvalho Polite, Marcia Bernardino
    d'Almeida Pereira, Ricardo Antonio
    Mota, Mariza
    Bianco, Celso
    Kutner, Jose Mauro
    TRANSFUSION, 2015, 55 (09) : 2291 - 2292
  • [36] HEMOGLOBIN-A2 MEASUREMENT USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    DEACONSMITH, R
    LORD, I
    MEDICAL LABORATORY SCIENCES, 1992, 49 (02): : 138 - 140
  • [37] QUANTITATION OF HEMOGLOBIN COMPONENTS BY HIGH-PERFORMANCE CATION-EXCHANGE LIQUID-CHROMATOGRAPHY - ITS USE IN DIAGNOSIS AND IN THE ASSESSMENT OF CELLULAR-DISTRIBUTION OF HEMOGLOBIN-VARIANTS
    KUTLAR, A
    KUTLAR, F
    WILSON, JB
    HEADLEE, MG
    HUISMAN, THJ
    AMERICAN JOURNAL OF HEMATOLOGY, 1984, 17 (01) : 39 - 53
  • [38] SEPARATION OF GLYCATED HEMOGLOBIN-A1C BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY ON A NONPOROUS EXCHANGER
    NAKATANI, S
    KITAMURA, T
    YAMASAKI, Y
    KATO, Y
    CHROMATOGRAPHIA, 1991, 31 (9-10) : 505 - 506
  • [39] High-Performance Liquid Chromatography for Screening of Abnormal Hemoglobins in Blood Donors Allows the Identification of Diabetic Individuals through the Detection of A1C Hemoglobin
    Pereira, R. A.
    Polite, M. B.
    Cabral, S. P.
    Farinha, M. T.
    Lira, S. C.
    Mota, M. A.
    Levi, J.
    Kutner, J. M.
    TRANSFUSION, 2013, 53 : 99A - 99A
  • [40] Interference of hemoglobin D in hemoglobin A2 measurement by cation-exchange HPLC -: Response
    Dash, S
    CLINICAL CHEMISTRY, 1999, 45 (08) : 1318 - 1318