Voltage Endurance Testing Stator insulation systems for inverter-fed machines

被引:18
|
作者
Stranges, Meredith K. W. [1 ]
Stone, Greg C. [2 ]
Bogh, Dennis L.
机构
[1] Gen Elect, Peterborough, ON, Canada
[2] IRIS Power, Mississauga, ON, Canada
关键词
Variable speed drives; IEC; Formal specifications; Insulation; Aging; Partial discharges;
D O I
10.1109/MIAS.2009.934439
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
There is an industry need for suitable methods to qualify medium- and high-voltage stator-insulation systems for inverter duty applications. The technical specification (TS) International Electrotechnical Commission (IEC) 60034-18-42 has been written to address the unique requirements of form-wound micaceous systems to withstand inverter pulses characterized by elevated voltage, fast rise times, and high-frequency impulse-repetition rates. These machines do not operate under the same aging conditions as those supplied by sinusoidal power or as motors with random wound stators supplied by pulsewidth modulated (PWM) drives. Depending on the specific waveform characteristics observed at the machine terminals, the ground-wall PE: Please note that the correction given to close up "Ground-wall" has been ignored. Kindly confirm, insulation, turn insulation, slot-corona suppression, and end-winding voltage-grading systems are significantly affected by aging factors such as partial discharge (PD) and elevated temperature. The TS offers technically sound guidelines to manufacturers and users describing test procedures to prove the electrical and thermal reliability of these components. Like IEC 60034-18-41 for low-voltage systems, the new technical specification will significantly impact construction and testing of National Electric Manufacturing Association (NEMA) motors. This article describes the theoretical and practical considerations of the specification. © 2009 IEEE.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 50 条
  • [41] Development of Repetitive Voltage Impulse Generator and Automatic Repetitive PD Inception Voltage Measurement System for Testing Inverter-fed Motor Insulation
    Hikita, Masayuki
    Ueno, Takahisa
    Kudo, Yuki
    Kozako, Masahiro
    Ogawa, Hiroyuki
    Sakurai, Takayuki
    Nakayama, Kazuhisa
    Yoshimitsu, Tetsuo
    Hirose, Tatsuya
    Hiroshima, Satoshi
    [J]. 2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 145 - 148
  • [42] Influence of Cable Insulation Structure on Terminal Over-voltage of Inverter-fed Motor
    Zhu Yongzhan
    Liu Xuezhong
    Gao Chao
    Deng Xianbo
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON SOLID DIELECTRICS, VOLS 1 AND 2, 2007, : 75 - 78
  • [43] The influence of impulsive voltage frequency on PD features in turn insulation of inverter-fed motors
    Wang, Peng
    Cavallini, Andrea
    Montanan, Gian Carlo
    [J]. 2014 IEEE CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2014, : 35 - 38
  • [44] A High Voltage Repetitive Square Wave Voltage Generator Used for Endurance Evaluation of Inverter-fed Motors
    Wang, Peng
    Li, Jinquan
    Wang, Jian
    Cavallini, Andrea
    Zhang, Jiawei
    [J]. 2017 INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATING MATERIALS (ISEIM), VOLS 1 & 2, 2017, : 411 - 414
  • [45] Silica Nanofilled Varnish Designed for Electrical Insulation of Low Voltage Inverter-fed Motors
    Nguyen, Manh Quan
    Malec, David
    Mary, Dominique
    Werynski, Piotr
    Gornicka, Barbara
    Therese, Laurent
    Guillot, Philippe
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2010, 17 (05) : 1349 - 1356
  • [46] Design of a Rectangular Wave High Voltage Generator for the Evaluation of Inverter-Fed Motor Insulation
    Akram, Shakeel
    Liu, Xinting
    Wang, Peng
    Meng, Pengfei
    Castellon, Jerome
    Cavallini, Andrea
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (05) : 4485 - 4493
  • [47] Development of insulation system to prevent local carbonization inside stator core of a product inverter-fed motor
    Yoshitake, Yuichiro
    Kojima, Hiroaki
    Kasai, Yuki
    Maruyama, Shoichi
    Kojima, Hiroki
    Hayakawa, Naoki
    [J]. IEEJ Transactions on Fundamentals and Materials, 2021, 141 (04): : 260 - 268
  • [48] A Novel Online Stator Ground-Wall Insulation Monitoring Scheme for Inverter-Fed AC Motors
    Zhang, Pinjia
    Younsi, Karim
    Neti, Prabhakar
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (03) : 2201 - 2207
  • [49] Insulation failure prediction in inverter-fed induction machines using line-neutral voltages
    Cash, MA
    Habetler, TG
    [J]. APEC '98 - THIRTEENTH ANNUAL APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 2, 1998, : 1035 - 1039
  • [50] A Novel Online Stator Ground-wall Insulation Monitoring Scheme for Inverter-fed AC Motors
    Zhang, Pinjia
    Younsi, Karim
    Neti, Prabhakar
    [J]. 2013 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2013, : 3541 - 3547