Voltage Endurance Testing Stator insulation systems for inverter-fed machines

被引:18
|
作者
Stranges, Meredith K. W. [1 ]
Stone, Greg C. [2 ]
Bogh, Dennis L.
机构
[1] Gen Elect, Peterborough, ON, Canada
[2] IRIS Power, Mississauga, ON, Canada
关键词
Variable speed drives; IEC; Formal specifications; Insulation; Aging; Partial discharges;
D O I
10.1109/MIAS.2009.934439
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
There is an industry need for suitable methods to qualify medium- and high-voltage stator-insulation systems for inverter duty applications. The technical specification (TS) International Electrotechnical Commission (IEC) 60034-18-42 has been written to address the unique requirements of form-wound micaceous systems to withstand inverter pulses characterized by elevated voltage, fast rise times, and high-frequency impulse-repetition rates. These machines do not operate under the same aging conditions as those supplied by sinusoidal power or as motors with random wound stators supplied by pulsewidth modulated (PWM) drives. Depending on the specific waveform characteristics observed at the machine terminals, the ground-wall PE: Please note that the correction given to close up "Ground-wall" has been ignored. Kindly confirm, insulation, turn insulation, slot-corona suppression, and end-winding voltage-grading systems are significantly affected by aging factors such as partial discharge (PD) and elevated temperature. The TS offers technically sound guidelines to manufacturers and users describing test procedures to prove the electrical and thermal reliability of these components. Like IEC 60034-18-41 for low-voltage systems, the new technical specification will significantly impact construction and testing of National Electric Manufacturing Association (NEMA) motors. This article describes the theoretical and practical considerations of the specification. © 2009 IEEE.
引用
收藏
页码:12 / 18
页数:7
相关论文
共 50 条
  • [31] An Online Groundwall and Phase-to-Phase Stator Insulation Monitoring Method for Inverter-Fed Machine
    Zheng, Dayong
    Zhang, Pinjia
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (06) : 5303 - 5313
  • [32] Inverter-Embedded Partial Discharge Testing for Reliability Enhancement of Stator Winding Insulation in Low Voltage Machines
    Lee, Hyeonjun
    Kim, Hanju
    Jeong, Jigyun
    Lee, Kibok
    Lee, Sang Bin
    Stone, Greg
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2022, 58 (02) : 2088 - 2096
  • [33] Influence of Current Transducer Transfer Properties on Stator Insulation Condition Monitoring of Inverter-fed Drives
    Zoeller, C.
    Vogelsberger, M. A.
    Fahrner, Walter
    Wolbank, Th. M.
    [J]. 2016 INTERNATIONAL SYMPOSIUM ON POWER ELECTRONICS, ELECTRICAL DRIVES, AUTOMATION AND MOTION (SPEEDAM), 2016, : 55 - 60
  • [34] Analysis of voltage distribution in stator winding of IGBT PWM inverter-fed induction motors
    Hwang, DH
    Lee, KC
    Jeon, JW
    Kim, YJ
    Kim, MH
    Kim, DH
    [J]. ISIE 2005: PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS 2005, VOLS 1- 4, 2005, : 945 - 950
  • [35] Adverse effects in voltage source inverter-fed drive systems
    Peroutka, Z
    Kus, V
    [J]. APEC 2002: SEVENTEENTH ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION, VOLS 1 AND 23, 2002, : 557 - 563
  • [36] Effect of varistors for overvoltage protection in inverter-fed drives on the voltage distribution in the stator winding
    Rocks, Alexander
    Hinrichsen, Volker
    [J]. CONFERENCE RECORD OF THE 2008 IEEE INTERNATIONAL SYMPOSIUM ON ELECTRICAL INSULATION, VOLS 1 AND 2, 2008, : 624 - 627
  • [37] High-Frequency Carrier-Signal Voltage Selection for Stator Winding Fault Diagnosis in Inverter-Fed AC Machines
    Briz, Fernando
    Degner, Michael W.
    Garcia, Pablo
    Diez, Alberto B.
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2008, 55 (12) : 4181 - 4190
  • [38] MECHANICAL TESTING OF HIGH VOLTAGE STATOR INSULATION SYSTEMS
    MAUGHAN, CV
    GIBBS, EE
    GIAQUINT.EV
    [J]. IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1970, PA89 (08): : 1946 - &
  • [39] FUZZY CONTROLLER FOR INVERTER-FED INDUCTION MACHINES
    MIR, SA
    ZINGER, DS
    ELBULUK, ME
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1994, 30 (01) : 78 - 84
  • [40] Development of Repetitive Voltage Impulse Generator and Automatic Repetitive PD Inception Voltage Measurement System for Testing Inverter-fed Motor Insulation
    Hikita, Masayuki
    Ueno, Takahisa
    Kudo, Yuki
    Kozako, Masahiro
    Ogawa, Hiroyuki
    Sakurai, Takayuki
    Nakayama, Kazuhisa
    Yoshimitsu, Tetsuo
    Hirose, Tatsuya
    Hiroshima, Satoshi
    [J]. 2012 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA (CEIDP), 2012, : 145 - 148