Optimal dispatch of generating units of the Itaipu hydroelectric plant

被引:122
|
作者
Arce, A [1 ]
Ohishi, T
Soares, S
机构
[1] Itaipu Binac, Operat Syst Dept, Campinas, Brazil
[2] State Univ Campinas, Fac Elect & Computat Engn, Campinas, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
hydroelectric power generation; optimization method; scheduling; unit commitment;
D O I
10.1109/59.982207
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper is concerned with the optimal dispatch of generating units of Itaipu, the world's largest hydroelectric plant in operation. Itaipu is a 12.6 GW hydro plant, located on the Parana river, in South America, composed of 18 identical 700 MW generating units. A dynamic programming model has been developed to optimize the number of generating units in operation at each hour of the day in order to attain the total generation scheduling of the plant in the most economic way. The model highlights the tradeoff between start-up/shut-down of generating units and hydro power efficiency, taking into account variations in tailrace elevation, penstock head losses and turbine-generator efficiencies. The methodology has been tested for a typical generation scheduling, and the results show that the number of the turbine-generator sets dispatched has a major influence on the overall hydroplant efficiency, and therefore it is a key aspect to be considered in the dispatch of hydro generating units. In the case of ltaipu, the economic benefits, in terms of greater power efficiency with respect to actual operation. are in the range of millions of dollars per year.
引用
收藏
页码:154 / 158
页数:5
相关论文
共 50 条
  • [31] AN ADAPTIVE MULTIVARIABLE CONTROL-SYSTEM FOR HYDROELECTRIC GENERATING-UNITS
    HEGGLID, GJ
    MODELING IDENTIFICATION AND CONTROL, 1983, 4 (02) : 63 - 81
  • [32] Study on the 3D dynamic simulation of hydroelectric generating units
    Chen, Y.
    Li, Z.
    Dianli Xitong Zidonghue/Automation of Electric Power Systems, 2001, 25 (08): : 49 - 52
  • [33] Data-Driven Modeling of Operating Characteristics of Hydroelectric Generating Units
    Hunter-Rinderle R.
    Sioshansi R.
    Current Sustainable/Renewable Energy Reports, 2021, 8 (04): : 199 - 206
  • [34] OPTIMAL SCHEDULING OF THERMAL GENERATING UNITS
    TURGEON, A
    IEEE TRANSACTIONS ON AUTOMATIC CONTROL, 1978, 23 (06) : 1000 - 1005
  • [35] CRITERIA OF OPTIMAL CONTROL OF GENERATING UNITS
    DUEL, MA
    THERMAL ENGINEERING, 1973, 20 (03) : 42 - 48
  • [36] Evaluation of Optimization Algorithms to Adjust Efficiency Curves for Hydroelectric Generating Units
    Hidalgo, Ieda G.
    Fontane, Darrell G.
    Arabi, Mazdak
    Lopes, Joao E. G.
    Andrade, Jose G. P.
    Ribeiro, Lubienska C. L. J.
    JOURNAL OF ENERGY ENGINEERING, 2012, 138 (04) : 172 - 178
  • [37] A COMPREHENSIVE CONDITION MONITORING-SYSTEM FOR HYDROELECTRIC GENERATING-UNITS
    MECHEFSKE, CK
    STEPHENS, MJ
    TURNER, GA
    MACDONALD, JA
    PALYLYK, RA
    POLLOCK, B
    FRANKLIN, DE
    INSIGHT, 1994, 36 (04) : 238 - 244
  • [38] ELECTRICAL AND RELATED DESIGN ASPECTS OF ITAIPU HYDROELECTRIC PROJECT
    DEMORAES, J
    RODRIGUEZ, J
    SALATKO, VF
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (05): : 1012 - 1020
  • [40] Pumped Hydro Units Optimal Dispatch by Refined PSO
    Chen, Po-Hung
    Kuo, Cheng-Chien
    Chen, Fu-Hsien
    Chen, Cheng-Chuan
    PROCEEDINGS OF THE 8TH WSEAS INTERNATIONAL CONFERENCE ON ELECTRIC POWER SYSTEMS, HIGH VOLTAGES, ELECTRIC MACHINES, 2008, : 195 - 200