Optimal Technique of reliability and quality Assessment of two-area interconnected power systems

被引:1
|
作者
Alshammari, Badr Mesned [1 ]
Guesmi, Tawfik [1 ]
Eleiwa, Mohammed [1 ]
Abbassi, Rabeh [1 ]
Alghassab, Mohammed [2 ]
机构
[1] Univ Hail, Elect Engn Dept, Hail, Saudi Arabia
[2] Shaqra Univ, Elect Engn Dept, Shaqraa, Saudi Arabia
来源
PRZEGLAD ELEKTROTECHNICZNY | 2020年 / 96卷 / 09期
关键词
Power systems; Reliability Assessment; interconnected systems; quality;
D O I
10.15199/48.2020.09.34
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The evaluated reliability and quality measures, which are important to assess the reserve capabilities of the power system for various operating scenarios, are probabilistic in nature. To improve the reliability and quality of two area interconnected power systems must be to make sure that the ability of one area to deal with compensate the deficiency in the other area. This paper presents a novel assessment technique of two-area interconnected power system based on the reliability and quality measures, as well as, the capacity and situation of tie line and the Load Not-Served (LNS). Systems with hundreds of buses and tens of complex stations can only be analyzed using advanced and numerically effective large-scale algorithms for reliability and quality assessment as demonstrated in this paper. Practical applications are additionally exhibited, for demonstration purposes, to the Saudi electricity power networks.
引用
收藏
页码:167 / 170
页数:4
相关论文
共 50 条
  • [31] Optimal power dispatch technique using spot price of electricity for multi-area interconnected systems
    Osmangazi Univ, Eskisehir, Turkey
    Turkish Journal of Electrical Engineering and Computer Sciences, 1996, 4 (1-3): : 55 - 78
  • [32] Model Predictive Load Frequency Control of two-area Interconnected Time Delay Power System with TCSC
    Deng, Yan
    Liu, Wenze
    2017 2ND ASIA CONFERENCE ON POWER AND ELECTRICAL ENGINEERING (ACPEE 2017), 2017, 199
  • [33] Linear active disturbance rejection control approach for load frequency control of two-area interconnected power system
    Huang, Congzhi
    Li, Jing
    Mu, Shicai
    Yan, Huaicheng
    TRANSACTIONS OF THE INSTITUTE OF MEASUREMENT AND CONTROL, 2019, 41 (06) : 1562 - 1570
  • [34] A Comparative Analysis of Load Frequency Control of Two-area Interconnected Hybrid Power System Using Lab VIEW
    Mishra, Dillip Kumar
    Panigrahi, Tapas K.
    Mohanty, Asit
    Ray, Prakask K.
    2017 PROGRESS IN ELECTROMAGNETICS RESEARCH SYMPOSIUM - FALL (PIERS - FALL), 2017, : 1953 - 1960
  • [35] Aggregation of Electric Vehicles for Emergency Frequency Control of Two-Area Interconnected Grid
    Agheb, Sareh
    Dong, Zhao Yang
    Ledwich, Gerard
    2020 IEEE PES INNOVATIVE SMART GRID TECHNOLOGIES EUROPE (ISGT-EUROPE 2020): SMART GRIDS: KEY ENABLERS OF A GREEN POWER SYSTEM, 2020, : 196 - 200
  • [36] Optimal Design of Automatic Generation Control Based on Simulated Annealing in Interconnected Two-Area Power System Using Hybrid PID-Fuzzy Control
    Magzoub, Muntasir A.
    Alquthami, Thamer
    ENERGIES, 2022, 15 (04)
  • [37] Modified TID controller for load frequency control of a two-area interconnected diverse-unit power system
    Ahmed, Mohamed
    Magdy, Gaber
    Khamies, Mohamed
    Kamel, Salah
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2022, 135
  • [38] Assessment of Reliability and Quality Levels in Power Systems
    El-Kady, Mohamed A.
    Alshammari, Badr M.
    2012 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2012,
  • [39] Study of Dynamic Responses of an Interconnected Two-Area all Thermal Power System with Governor and Boiler Nonlinearities using BBO
    Guha, Dipayan
    Roy, Provas Kumar
    Banerjee, Subrata
    2015 THIRD INTERNATIONAL CONFERENCE ON COMPUTER, COMMUNICATION, CONTROL AND INFORMATION TECHNOLOGY (C3IT), 2015,
  • [40] Optimal scheduling of interconnected power systems
    Koltsaklis, Nikolaos E.
    Gioulekas, Ioannis
    Georgiadis, Michael C.
    COMPUTERS & CHEMICAL ENGINEERING, 2018, 111 : 164 - 182