Optimal Technique of reliability and quality Assessment of two-area interconnected power systems

被引:1
|
作者
Alshammari, Badr Mesned [1 ]
Guesmi, Tawfik [1 ]
Eleiwa, Mohammed [1 ]
Abbassi, Rabeh [1 ]
Alghassab, Mohammed [2 ]
机构
[1] Univ Hail, Elect Engn Dept, Hail, Saudi Arabia
[2] Shaqra Univ, Elect Engn Dept, Shaqraa, Saudi Arabia
来源
PRZEGLAD ELEKTROTECHNICZNY | 2020年 / 96卷 / 09期
关键词
Power systems; Reliability Assessment; interconnected systems; quality;
D O I
10.15199/48.2020.09.34
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The evaluated reliability and quality measures, which are important to assess the reserve capabilities of the power system for various operating scenarios, are probabilistic in nature. To improve the reliability and quality of two area interconnected power systems must be to make sure that the ability of one area to deal with compensate the deficiency in the other area. This paper presents a novel assessment technique of two-area interconnected power system based on the reliability and quality measures, as well as, the capacity and situation of tie line and the Load Not-Served (LNS). Systems with hundreds of buses and tens of complex stations can only be analyzed using advanced and numerically effective large-scale algorithms for reliability and quality assessment as demonstrated in this paper. Practical applications are additionally exhibited, for demonstration purposes, to the Saudi electricity power networks.
引用
收藏
页码:167 / 170
页数:4
相关论文
共 50 条
  • [21] Investigation of reciprocal rank method for automatic generation control in two-area interconnected power system
    Meena, V. P.
    Singh, V. P.
    Guerrero, Josep M.
    MATHEMATICS AND COMPUTERS IN SIMULATION, 2024, 225 : 760 - 778
  • [22] An EID Load Frequency Control Method for Two-Area Interconnected Power System with Photovoltaic Generation
    Yang, Minghui
    Wang, Chunsheng
    Liu, Zijian
    He, Shuhang
    PROCEEDINGS OF THE 33RD CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2021), 2021, : 5662 - 5666
  • [23] Two-Area AGC in Interconnected System Under the Restructured Power System Using BFO Controller
    Gupta, S. K.
    Arya, Yogendra
    Shukla, Shivank
    Chawla, Pankaj
    2014 6TH IEEE POWER INDIA INTERNATIONAL CONFERENCE (PIICON), 2014,
  • [24] Automatic generation control of two-area electrical power systems via optimal fuzzy classical controller
    Arya, Yogendra
    JOURNAL OF THE FRANKLIN INSTITUTE-ENGINEERING AND APPLIED MATHEMATICS, 2018, 355 (05): : 2662 - 2688
  • [25] An Approach to Online Asynchronous Mode Prevention in Two-area Power Systems
    Hanh Thi Nguyet Nguyen
    Van Tu Dao
    2014 IEEE 27TH CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2014,
  • [26] Reliability assessment of restructured power systems using optimal load shedding technique
    Wang, P.
    Ding, Y.
    Goel, L.
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2009, 3 (07) : 628 - 640
  • [27] Optimal automatic generation control of two-area power systems with energy storage units under deregulated environment
    Arya, Yogendra
    Kumar, Narendra
    Gupta, S. K.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2017, 9 (06)
  • [28] Frequency Consensus Control for Two-area Flexible DC Interconnected System
    Li, Pengfei
    Li, Xialin
    Guo, Li
    Huang, Di
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 7304 - 7309
  • [29] Transient Stability Analysis of the Two-Area With AC/DC Paralleled Interconnected Power System in Different Operation
    Liu, Hongbo
    Zhang, Shuyu
    Sun, Li
    Zhang, Chong
    Peng, Xiaoyu
    FRONTIERS IN ENERGY RESEARCH, 2021, 9
  • [30] An analytical method for reliability evaluation of two interconnected power systems
    Samorodov, G. I.
    Krasilnikova, T. G.
    Yatsenko, R. A.
    Zilberman, S. M.
    2006 INTERNATIONAL CONFERENCE ON PROBABILISTIC METHODS APPLIED TO POWER SYSTEMS, VOLS 1 AND 2, 2006, : 781 - 786