Glaucoma diagnosis optic disc analysis comparing Cirrus spectral domain optical coherence tomography and Heidelberg retina tomograph II

被引:9
|
作者
Shin, Hye Young [1 ]
Park, Hae-Young Lopilly [1 ]
Jung, Kyoung In [1 ]
Park, Chan Kee [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
关键词
Cirrus spectral domain optical coherence tomography; Glaucoma; Optic nerve head analysis; Confocal scanning laser ophthalmoscopy imaging; NERVE-FIBER LAYER; THICKNESS MEASUREMENTS; TIME-DOMAIN; ABILITY; OCT;
D O I
10.1007/s10384-012-0205-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the diagnostic ability of optic nerve head parameters, measured by Cirrus spectral domain optical coherence tomography (SD OCT) and Heidelberg retina tomograph II (HRT II) to detect concomitant glaucoma. Cirrus OCT and HRT examinations of 62 eyes of 62 patients (32 with no perimetric glaucoma and 30 with concomitant perimetric glaucoma) evaluated between August 2010 and December 2010 were retrospectively analyzed and compared with regard to the optic disc morphometric parameter, disc area, rim area, cup-to-disc ratio (CDR), and cup volume. Receiver operating characteristic curves were constructed for the parameters and areas under the curves (AUCs) were compared. All parameters except disc area were significantly different between Cirrus OCT and HRT. Average cup-to-disc ratio (CDR), vertical CDR, and cup volume were greater when measured by OCT compared with HRT II (P = 0.002, P < 0.001, and P < 0.001, respectively). Rim area was smaller by OCT than by HRT II (P < 0.001). Of the parameters evaluated, rim area (0.938), average CDR (0.865), and vertical CDR (0.897) had higher AUCs with OCT than with HRT II. Glaucoma diagnostic capability using the AUC was greater for OCT than for the HRT. Optic nerve head parameters measured by Cirrus OCT seem to be useful in differentiating glaucomatous optic nerve heads. The two types of instrument compared here should not be used interchangeably to obtain measurements of the optic disc for diagnosis of glaucoma.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [31] Documentation of optic disc melanocytoma by spectral and time domain optical coherence tomography
    Shah, Vinay A.
    Vincent, Ryan D.
    Desai, Komal
    Gallimore, Gary
    Rupani, Mahendra
    CANADIAN JOURNAL OF OPHTHALMOLOGY-JOURNAL CANADIEN D OPHTALMOLOGIE, 2009, 44 (05): : 603 - 604
  • [32] Comparison of Spectral Domain Optical Coherence Tomography and Heidelberg Retinal Tomograph III Retina Module in the Measurement of Clinically Significant Diabetic Macular Edema
    Guzey, Mustafa
    Adibelli, Fatih Mehmet
    Ozcan, Huseyin
    OPHTHALMOLOGICA, 2014, 232 : 53 - 53
  • [33] Diagnostic ability of the Heidelberg retina tomograph, optical coherence tomograph, and scanning laser polarimeter in open-angle glaucoma
    Pueyo, Victoria
    Polo, Vicente
    Larrosa, Jose Manuel
    Ferreras, Antonio
    Pablo, Luis Emilio
    Honrubia, Francisco Manuel
    JOURNAL OF GLAUCOMA, 2007, 16 (02) : 173 - 177
  • [34] Diagnosis of glaucoma and detection of glaucoma progression using spectral domain optical coherence tomography
    Grewal, Dilraj S.
    Tanna, Angelo P.
    CURRENT OPINION IN OPHTHALMOLOGY, 2013, 24 (02) : 150 - 161
  • [35] Structure-Function Relationship in Glaucoma Using the Cirrus Spectral Domain Optical Coherence Tomograph and Standard Automated Perimetry
    Leite, M. T.
    Zangwill, L. M.
    Weinreb, R. N.
    Sample, P. A.
    Rao, H. L.
    Alencar, L. M.
    Bow, C.
    Medeiros, F. A.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] Longitudinal Change Detected by Spectral Domain Optical Coherence Tomography in the Optic Nerve Head and Peripapillary Retina in Experimental Glaucoma
    Strouthidis, Nicholas G.
    Fortune, Brad
    Yang, Hongli
    Sigal, Ian A.
    Burgoyne, Claude F.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (03) : 1206 - 1219
  • [37] Cirrus High-definition Optical Coherence Tomography Versus Spectral Optical Coherence Tomography/Scanning Laser Ophthalmoscopy in the Diagnosis of Glaucoma
    Koh, Kyung Min
    Jin, Sunyoung
    Hwang, Young Hoon
    CURRENT EYE RESEARCH, 2014, 39 (01) : 62 - 68
  • [38] Individual vs simultaneous macular and optic disc measurements with spectral domain optical coherence tomography in glaucoma and healthy eyes
    Venkataraman, Abinaya Priya
    Al-Soboh, Loujain
    Hedstrom, Johan
    Dominguez-Vicent, Alberto
    SCIENTIFIC REPORTS, 2024, 14 (01)
  • [39] Individual vs simultaneous macular and optic disc measurements with spectral domain optical coherence tomography in glaucoma and healthy eyes
    Abinaya Priya Venkataraman
    Loujain Al-Soboh
    Johan Hedström
    Alberto Domínguez-Vicent
    Scientific Reports, 14
  • [40] Regression Analysis of Optical Coherence Tomography Disc Variables for Glaucoma Diagnosis
    Richter, Grace M.
    Zhang, Xinbo
    Tan, Ou
    Francis, Brian A.
    Chopra, Vikas
    Greenfield, David S.
    Varma, Rohit
    Schuman, Joel S.
    Huang, David
    JOURNAL OF GLAUCOMA, 2016, 25 (08) : 634 - 642