Glaucoma diagnosis optic disc analysis comparing Cirrus spectral domain optical coherence tomography and Heidelberg retina tomograph II

被引:9
|
作者
Shin, Hye Young [1 ]
Park, Hae-Young Lopilly [1 ]
Jung, Kyoung In [1 ]
Park, Chan Kee [1 ]
机构
[1] Catholic Univ Korea, Seoul St Marys Hosp, Coll Med, Dept Ophthalmol & Visual Sci, Seoul 137701, South Korea
关键词
Cirrus spectral domain optical coherence tomography; Glaucoma; Optic nerve head analysis; Confocal scanning laser ophthalmoscopy imaging; NERVE-FIBER LAYER; THICKNESS MEASUREMENTS; TIME-DOMAIN; ABILITY; OCT;
D O I
10.1007/s10384-012-0205-9
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
To evaluate the diagnostic ability of optic nerve head parameters, measured by Cirrus spectral domain optical coherence tomography (SD OCT) and Heidelberg retina tomograph II (HRT II) to detect concomitant glaucoma. Cirrus OCT and HRT examinations of 62 eyes of 62 patients (32 with no perimetric glaucoma and 30 with concomitant perimetric glaucoma) evaluated between August 2010 and December 2010 were retrospectively analyzed and compared with regard to the optic disc morphometric parameter, disc area, rim area, cup-to-disc ratio (CDR), and cup volume. Receiver operating characteristic curves were constructed for the parameters and areas under the curves (AUCs) were compared. All parameters except disc area were significantly different between Cirrus OCT and HRT. Average cup-to-disc ratio (CDR), vertical CDR, and cup volume were greater when measured by OCT compared with HRT II (P = 0.002, P < 0.001, and P < 0.001, respectively). Rim area was smaller by OCT than by HRT II (P < 0.001). Of the parameters evaluated, rim area (0.938), average CDR (0.865), and vertical CDR (0.897) had higher AUCs with OCT than with HRT II. Glaucoma diagnostic capability using the AUC was greater for OCT than for the HRT. Optic nerve head parameters measured by Cirrus OCT seem to be useful in differentiating glaucomatous optic nerve heads. The two types of instrument compared here should not be used interchangeably to obtain measurements of the optic disc for diagnosis of glaucoma.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 50 条
  • [21] Glaucoma-Induced Optic Disc Morphometric Changes and Glaucoma Diagnostic Ability of Heidelberg Retina Tomograph II in Highly Myopic Eyes
    Mayama, Chihiro
    Tsutsumi, Tae
    Saito, Hitomi
    Asaoka, Ryo
    Tomidokoro, Atsuo
    Iwase, Aiko
    Otani, Shinichiro
    Miyata, Kazunori
    Araie, Makoto
    PLOS ONE, 2014, 9 (01):
  • [22] Comparison of Heidelberg retina tomography, optical coherence tomography and Humphrey visual field in early glaucoma diagnosis
    Wang, Hong
    Tao, Yuan
    Sun, Xiao-Ling
    Zhuang, Kang
    JOURNAL OF INTERNATIONAL MEDICAL RESEARCH, 2013, 41 (05) : 1594 - 1605
  • [23] Analysis of optic disc change using the Heidelberg Retina Tomograph in an acquired pit of the optic nerve
    Oh, JY
    Park, KH
    OPHTHALMIC SURGERY LASERS & IMAGING, 2004, 35 (04): : 325 - 327
  • [24] Optic disc analysis with Heidelberg Retina Tomography III in glaucoma with unilateral visual field defects
    Ge-Ge Xiao
    Ling-Ling Wu
    Japanese Journal of Ophthalmology, 2010, 54 : 305 - 309
  • [25] Evaluation of subjects with a moderate cup to disc ratio using optical coherence tomography and Heidelberg retina tomograph 3: Impact of the disc area
    Ulas, Fatih
    Dogan, Umit
    Kaymaz, Abdulgani
    Celik, Fatih
    Celebi, Serdal
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2015, 63 (01) : 3 - 8
  • [26] Optic disc analysis with Heidelberg Retina Tomography III in glaucoma with unilateral visual field defects
    Xiao, Ge-Ge
    Wu, Ling-Ling
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (04) : 305 - 309
  • [27] Structure-Function Relationship between Spectral Domain Optical Coherence Tomography, Heidelberg Retina Tomograph and Flicker Defined Form Perimetry in Patients with Ocular Hypertension and Preperimetric Glaucoma
    Marziani, Ermengarda
    de Polo, Laura
    Collaku, Erma
    Weiszberger, Elena
    Acquistapace, Alessandra
    Giani, Andrea
    Blini, Mirella
    Staurenghi, Giovanni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (15)
  • [28] Development of a novel reference plane for the Heidelberg Retina Tomograph with optical coherence tomography measurements
    Park, KH
    Caprioli, J
    JOURNAL OF GLAUCOMA, 2002, 11 (05) : 385 - 391
  • [29] Optical coherence tomography and Heidelberg retina tomography for superior segmental optic hypoplasia
    Lee, H. J.
    Kee, C.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (11) : 1468 - 1473
  • [30] Logistic Regression Analysis for Glaucoma Diagnosis Using Spectral Domain Optical Coherence Tomography
    Ferreras, A.
    Pajarin, A. B.
    Pablo, L. E.
    Calvo, P.
    Monsalve, B.
    Fogagnolo, P.
    Figus, M.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)