Tolerance analysis on nested conical Wolter-I X-ray telescope

被引:1
|
作者
Mu, Baozhong [1 ]
Xie, Yichun [1 ]
Chen, Shenghao [1 ]
Yi, Shengzhen [1 ]
Wang, Xin [1 ]
Wang, Zhanshan [1 ]
机构
[1] Tongji Univ, Key Lab Special Artificial Microstruct Mat & Tech, Shanghai 200092, Peoples R China
关键词
nested conical Wolter-I X-ray telescope; mirror-position tolerance; alignment-bar tolerance; surface-figure tolerance;
D O I
10.1117/12.925520
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
The degradation of image quality of the nested conical Wolter-I X-ray telescope mainly results from mirror-position tolerance, alignment-bar tolerance and surface-figure tolerance. The analytical approach of the three kinds of tolerance was presented in this paper. Based on the predetermined initial structure, we analyzed and compared image qualities with different tolerances. Furthermore, we simulated the distribution of the spot diagrams and calculated the spatial resolution of the entire system. Shift along the optical axis (Z axis) and rotation around it have no effects on the image quality for position tolerances. However, shift along X, Y directions and rotation around X, Y axes change the distribution of spot diagrams and decrease the spatial resolution. For higher resolution, we should control the alignment-bar tolerance by placing a displacement sensor at the end of the alignment bar. The angular resolution increases from 1' to 13 '' as the alignment-bar tolerance decreased from +/- 15um to +/- 3um. With respect to surface-figure tolerance, we simulated image qualities by inserting Zernike polynomial to the surface.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] X-ray scattering microscope with a Wolter mirror
    Takano, H
    Aoki, S
    Kumegawa, M
    Watanabe, N
    Ohhigashi, T
    Aota, T
    Yamamoto, K
    Yokosuka, H
    Tanoue, R
    Tsujita, Y
    Ando, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (07): : 2629 - 2633
  • [42] A generalized Wolter Type I design for the solar X-ray imager (SXI)
    Harvey, JE
    Thompson, PL
    X-RAY OPTICS, INSTRUMENTS, AND MISSIONS II, 1999, 3766 : 173 - 183
  • [43] X-ray telescope
    Tucker, W
    SMITHSONIAN, 1998, 29 (06) : 18 - 18
  • [44] LABORATORY CHARACTERIZATION OF WOLTER X-RAY OPTICS
    REMINGTON, BA
    MORALES, RI
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (01): : 703 - 705
  • [45] Wolter type I x-ray focusing mirror using multilayer coatings
    Chon, Kwon Su
    Namba, Yoshiharu
    Yoon, Kwon-Ha
    APPLIED OPTICS, 2006, 45 (19) : 4609 - 4616
  • [46] HIGH-RESOLUTION LARGE AREA MODULAR ARRAY OF REFLECTORS (LAMAR) WOLTER TYPE-I X-RAY TELESCOPE FOR SPACELAB
    CATURA, RC
    ACTON, LW
    BROWN, WA
    GILBRETH, CW
    SPRINGER, LA
    VIEIRA, JR
    CULHANE, JL
    MASON, IW
    SIEGMUND, O
    PATRICK, TJ
    SHEATHER, PH
    POUNDS, KA
    COOKE, BA
    EVANS, K
    PYE, J
    SMITH, G
    WELLS, A
    SPRAGG, JE
    WHITFORD, CH
    GARMIRE, G
    MARGON, B
    FABIAN, A
    OPTICAL ENGINEERING, 1983, 22 (01) : 132 - 139
  • [47] The research of nested grazing incidence X-ray telescope with high angular resolution
    Shen, Zhengxiang
    Jun, Yu
    Ma, Bin
    Huang, Qiushi
    Wang, Xiaoqiang
    Liao, Yinyu
    Wang, Kun
    Wang, Zhanshan
    OPTICS FOR EUV, X-RAY, AND GAMMA-RAY ASTRONOMY IX, 2019, 11119
  • [48] Improvement of angular resolution of a thin-foil-nested X-ray telescope
    Hayashi, Takayuki
    Sato, Takuro
    Ishida, Manabu
    Maeda, Yoshitomo
    Mori, Hideyuki
    Nakamura, Ryoko
    Shirata, Takayuki
    Someya, Kentaro
    Ogasakka, Yasushi
    Torii, Kenichi
    ADVANCES IN X-RAY/EUV OPTICS AND COMPONENTS IV, 2009, 7448
  • [49] Nested focusing X-ray telescope with lightweight and large photon collecting area
    Li B.
    Li H.
    Cao Y.
    Sang P.
    Liu Y.
    Yu D.
    Hangkong Xuebao/Acta Aeronautica et Astronautica Sinica, 2023, 44 (03):