X-ray scattering microscope with a Wolter mirror

被引:6
|
作者
Takano, H [1 ]
Aoki, S
Kumegawa, M
Watanabe, N
Ohhigashi, T
Aota, T
Yamamoto, K
Yokosuka, H
Tanoue, R
Tsujita, Y
Ando, M
机构
[1] JASRI Spring 8, Mikazuki, Hyogo 6795198, Japan
[2] Univ Tsukuba, Inst Phys Appl, Ibaraki 3058573, Japan
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2002年 / 73卷 / 07期
关键词
D O I
10.1063/1.1487888
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Full-field x-ray scattering microscopic images were obtained with a Wolter mirror (x10 magnification). A synchrotron radiation white beam (4-20 keV) from a bending magnet beamline at the Photon Factory was used to obtain x-ray scattering images. The system was available for multi-kilo-electron-volt x-ray range (4-12 keV) with the Wolter mirror. The image was formed only with scattered x rays from the object, which is kind of a dark-field image. Very low absorptive materials could be imaged with this microscope. Sensitivity of the system was evaluated and also the detection limit was estimated. (C) 2002 American Institute of Physics.
引用
收藏
页码:2629 / 2633
页数:5
相关论文
共 50 条
  • [1] Optimization of a Wolter type I mirror for a soft X-ray microscope
    Chon, KS
    Namba, Y
    Yoon, KH
    PRECISION ENGINEERING-JOURNAL OF THE INTERNATIONAL SOCIETIES FOR PRECISION ENGINEERING AND NANOTECHNOLOGY, 2006, 30 (02): : 223 - 230
  • [2] Full-field x-ray fluorescence imaging microscope with a Wolter mirror
    Takeuchi, A
    Aoki, S
    Yamamoto, K
    Takano, H
    Watanabe, N
    Ando, M
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (03): : 1279 - 1285
  • [3] Phase-contrast hard x-ray imaging microscope with Wolter mirror optics
    Watanabe, N
    Aoki, S
    Takano, H
    Yamamoto, K
    Takeuchi, A
    Tsubaki, H
    Aota, T
    X-RAY MICROSCOPY, PROCEEDINGS, 2000, 507 : 84 - 91
  • [4] Laboratory-size x-ray microscope using Wolter mirror optics and an electron-impact x-ray source
    Ohba, Akira
    Nakano, Tomoyasu
    Onoda, Shinobu
    Mochizuki, Takahiro
    Nakamoto, Katsuhiro
    Hotaka, Hisaya
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (09):
  • [5] Imaging X-ray fluorescence microscope with a Wolter-type grazing-incidence mirror
    Aoki, S
    Takeuchi, A
    Ando, M
    JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 : 1117 - 1118
  • [6] Soft x-ray scanning photoelectron microscope using Wolter-type focusing mirror
    Hasegawa, M
    Yoneyama, A
    Ninomiya, K
    JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1996, 80 : 361 - 364
  • [7] X-ray fluorescence microtomography with a Wolter mirror system
    Watanabe, N
    Yamamoto, K
    Takano, H
    Ohigashi, T
    Yokosuka, H
    Aota, T
    Aoki, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 : 837 - 840
  • [8] WOLTER X-RAY MICROSCOPE CHARACTERIZATION MEASUREMENTS ON NOVA
    REMINGTON, BA
    GLENDINNING, SG
    WALLACE, RJ
    ROTHMAN, S
    MORALES, R
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10): : 5080 - 5082
  • [10] 4-FRAME GATED WOLTER X-RAY MICROSCOPE
    ELLIS, RJ
    TREBES, JE
    PHILLION, DW
    KILKENNY, JD
    GLENDINNING, SG
    WIEDWALD, JD
    LEVESQUE, RA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1990, 61 (10): : 2759 - 2761