A regulation capacity reset strategy for HVAC frequency regulation control

被引:27
|
作者
Cai, Jie [1 ]
Braun, James E. [2 ]
机构
[1] Univ Oklahoma, Sch Aerosp & Mech Engn, Norman, OK 73019 USA
[2] Purdue Univ, Sch Mech Engn, Ray W Herrick Labs, W Lafayette, IN 47907 USA
关键词
Frequency regulation control; HVAC power flexibility; Rooftop unit (RTU) control; ANCILLARY SERVICE;
D O I
10.1016/j.enbuild.2018.12.018
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The power grid has seen record demand for frequency regulation capacity in recent years due to the increased employment of renewable energy resources worldwide. Building thermal loads are flexible and thus, can be used as regulation reserves with proper control strategies. Previous studies have shown that building HVAC equipment can provide high-quality power grid regulation service with PJM performance scores of up to 0.98 and buildings' participation in the regulation market could bring significant economic benefits for building owners. However, the power flexibility in buildings is not persistent and the available HVAC regulation capacity has significant hour-by-hour variation due to building load and other operating constraints. This paper presents a regulation capacity reset strategy for HVAC regulation control that identifies the available regulation capacity and baseline power on the fly with real-time load and operation data. The strategy relies on a steady-state HVAC performance model derived from manufacturer performance data and implements a pseudo-optimization that seeks the maximum regulation capacity while respecting all operating constraints. The proposed strategy was implemented on a variable-speed rooftop unit (RTU) and validated with laboratory tests in psychrometric chambers. The test results show that the proposed reset strategy is effective in providing consistent high-quality regulation service with negligible impact on the indoor temperature control; the zone temperature deviation from the setpoint was within 0.3 degrees C for all the performed tests. The reset strategy was also simulated with a prototypical building diurnal load model to quantify the integrated regulation capacity for a typical summer day. Simulation results indicate the integrated HVAC regulation capacity throughout a summer day equals approximately 1/4 of the daily electrical energy use; and the estimated daily regulation credit can offset up to 26% of the daily HVAC electricity cost based on PJM historical prices. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:272 / 286
页数:15
相关论文
共 50 条
  • [31] Decentralized Primary Frequency Regulation Control Strategy for Vehicle-to-Grid
    Xu, Xingxing
    Zhang, Chun
    Gu, Long
    2016 3RD INTERNATIONAL CONFERENCE ON SYSTEMS AND INFORMATICS (ICSAI), 2016, : 217 - 222
  • [32] Frequency-trajectory-oriented control strategy for primary frequency regulation of wind farms
    Yang, Xusong
    Liu, Lei
    Gu, Xinyu
    Luo, Xianjue
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2023, 17 (20) : 4627 - 4646
  • [33] Coordinated Control Strategy and Optimal Capacity Configuration for Flywheel Energy Storage Participating in Primary Frequency Regulation of Power Grid
    Luo Y.
    Tian L.
    Wang Y.
    Li J.
    Li J.
    Jiang T.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (09): : 71 - 82
  • [34] Coordinated Voltage Control Strategy by Optimizing the Limited Regulation Capacity of Air Conditioners
    Hua, Yongzhu
    Xie, Qiangqiang
    Zheng, Liang
    Cui, Jiadong
    Shao, Lihuan
    Hu, Weiwei
    ENERGIES, 2022, 15 (09)
  • [35] State-shift priority based progressive load control of residential HVAC units for frequency regulation
    Shen, Yunwei
    Li, Yang
    Zhang, Qiwei
    Shi, Qingxin
    Li, Fangxing
    ELECTRIC POWER SYSTEMS RESEARCH, 2020, 182
  • [36] Experimental Evaluation of Frequency Regulation From Commercial Building HVAC Systems
    Lin, Yashen
    Barooah, Prabir
    Meyn, Sean
    Middelkoop, Timothy
    IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (02) : 776 - 783
  • [37] Dynamic Configuration Strategy for Frequency Regulation Reserve Capacity of Large-scale Wind Power for Promoting Peak Load Regulation
    Li S.
    Tu J.
    Shu Z.
    Zhong H.
    Xia Z.
    Luo Y.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2020, 44 (24): : 53 - 59
  • [38] Control Strategy of Primary Frequency Regulation for Wind Turbine Based on Segmented Rate of Change of Frequency
    Shan Y.
    Wang Z.
    Zhou C.
    Liu R.
    Liang D.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2022, 46 (11): : 19 - 26
  • [39] Control Strategy for Frequency Regulation using Battery Energy Storage with Optimal Utilization
    Jha, I. S.
    Sen, Subir
    Tiwari, Manish
    Singh, Manish Kumar
    2014 IEEE 6TH INDIA INTERNATIONAL CONFERENCE ON POWER ELECTRONICS (IICPE), 2014,
  • [40] Control strategy for primary frequency regulation with the participation of a quick response energy storage
    Jia T.
    Chen L.
    Min Y.
    Xu F.
    Xiong X.
    Zhao L.
    Feng Y.
    Qinghua Daxue Xuebao/Journal of Tsinghua University, 2021, 61 (05): : 429 - 436