Detection of γ-rays with a 3.5 1 liquid xenon ionization chamber triggered by the primary scintillation light

被引:10
|
作者
Aprile, E [1 ]
Bolotnikov, A [1 ]
Chen, DL [1 ]
Muhkerjee, R [1 ]
Xu, F [1 ]
机构
[1] Columbia Univ, Columbia Astrophys Lab, New York, NY 10027 USA
基金
美国国家航空航天局;
关键词
D O I
10.1016/S0168-9002(01)01204-9
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A gridded ionization chamber with a drift length of 4.5 cm and a total volume of 3.5 1, was operated with high-purity liquid xenon and extensively tested with gamma-rays from Cs-137, Na-22 and Co-60 radioactive sources. An electron lifetime in excess of I ins was inferred from two independent measurements. The electric Field dependence of the collected charge and energy resolution was studied in the range 0.1-4 kV/cm, for different gamma-ray energies, With an electric field of 4 kV/cm, the spectral performance of the detector is consistent with an energy resolution of 5.9% at 1 MeV, scaling with energy as E-0.5 The chamber was also used to detect the primary scintillation light produced by gamma-ray interactions in liquid xenon. The light signal was successfully used to trigger the acquisition of the charge signal with a FADC readout. A trigger efficiency of similar to85% was measured at 662 keV. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:636 / 650
页数:15
相关论文
共 50 条
  • [21] A liquid xenon ionization chamber in an all-fluoropolymer vessel
    LePort, F.
    Pocar, A.
    Bartoszek, L.
    DeVoe, R.
    Fierlinger, P.
    Flatt, B.
    Gratta, G.
    Green, M.
    Koffas, T.
    Diez, M. Montero
    Neilson, R.
    O'Sullivan, K.
    Waldman, S.
    Wodin, J.
    Woisard, D.
    Baussan, E.
    Breidenbach, M.
    Conley, R.
    Fairbank, W., Jr.
    Farine, J.
    Hall, C.
    Hall, K.
    Hallman, D.
    Hargrove, C.
    Hodgson, J.
    Jeng, S.
    Leonard, D. S.
    Mackay, D.
    Martin, Y.
    Odian, A.
    Ounalli, L.
    Piepke, A.
    Prescott, C. Y.
    Rowson, P. C.
    Skarpaas, K.
    Schenker, D.
    Sinclair, D.
    Stekhanov, V.
    Strickland, V.
    Virtue, C.
    Vuilleumier, J.-L.
    Vuilleumier, J.-M.
    Wamba, K.
    Weber, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (02): : 409 - 420
  • [22] Interplay between scintillation and ionization in liquid xenon Dark Matter searches
    Bezrukov, Fedor
    Kahlhoefer, Felix
    Lindner, Manfred
    ASTROPARTICLE PHYSICS, 2011, 35 (03) : 119 - 127
  • [23] DESIGN, CONSTRUCTION AND PERFORMANCE OF A LIQUID XENON AND LIQUID ARGON IONIZATION-CHAMBER
    IMEL, DA
    THOMAS, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (01): : 291 - 298
  • [24] Light yield of liquid and solid xenon irradiated with γ-rays
    Nuclear Instruments & Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1995, 367 (1-3):
  • [25] Time behaviour of the scintillation light in mixtures of liquid argon and xenon
    Conti, E
    Carugno, G
    Intravaia, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 382 (03): : 475 - 478
  • [26] Measurement of the refractive index of liquid xenon for intrinsic scintillation light
    Barkov, L.M.
    Grebenuk, A.A.
    Ryskulov, N.M.
    Stepanov, P.Yu.
    Zverev, S.G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1996, 379 (03): : 482 - 484
  • [27] Measurement of the refractive index of liquid xenon for intrinsic scintillation light
    Barkov, LM
    Grebenuk, AA
    Ryskulov, NM
    Stepanov, PY
    Zverev, SG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (03): : 482 - 483
  • [28] INVESTIGATION OF THE SCINTILLATION LIGHT FROM LIQUID ARGON DOPED WITH XENON
    MINERSKJOLD, M
    LINDBLAD, T
    LUNDJENSEN, B
    SZEKELY, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 336 (1-2): : 373 - 377
  • [29] Detection of scintillation light in coincidence with ionizing tracks in a liquid argon time projection chamber
    Cennini, P
    Revol, JP
    Rubbia, C
    Sergiampietri, F
    Bueno, A
    Campanelli, M
    Goudsmit, P
    Rubbia, A
    Periale, L
    Suzuki, S
    Chen, C
    Chen, Y
    He, K
    Huang, X
    Li, Z
    Lu, F
    Ma, J
    Xu, G
    Xu, Z
    Zhang, C
    Zhang, Q
    Zheng, S
    Cavanna, F
    Mazza, D
    Piano Mortari, G
    Petrera, S
    Rossi, C
    Mannocchi, G
    Picchi, P
    Arneodo, F
    De Mitri, I
    Palamara, O
    Cavalli, D
    Ferrari, A
    Sala, P
    di Tigliole, AB
    Cesana, A
    Terrani, M
    Zavattari, C
    Baibussinov, S
    Bettini, A
    Carpanese, C
    Centro, S
    Favaretto, D
    Pascoli, D
    Pepato, A
    Pietropaolo, F
    Ventura, S
    Benetti, P
    Calligarich, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 432 (2-3): : 240 - 248
  • [30] PERFORMANCE OF A LIQUID XENON TIME PROJECTION CHAMBER FOR LOW-ENERGY GAMMA-RAYS DETECTION
    CONTI, E
    MENEGUZZO, AT
    ONOFRIO, R
    CARUGNO, G
    BRESSI, G
    CERDONIO, S
    ZANELLO, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 356 (2-3): : 286 - 296