Topical contrast agents to improve soft-tissue contrast in the upper airway using cone beam CT: a pilot study

被引:5
|
作者
Alsufyani, N. A. [1 ]
Noga, M. L. [2 ]
Finlay, W. H. [3 ]
Major, P. W. [1 ]
机构
[1] Univ Alberta, Dept Dent, Edmonton, AB, Canada
[2] Univ Alberta, Dept Radiol & Diagnost Imaging, Edmonton, AB, Canada
[3] Univ Alberta, Dept Mech Engn, Edmonton, AB, Canada
关键词
administration; topical; contrast agents; cone beam computed tomography; NASAL IRRIGATION; BARIUM-SULFATE; DEPOSITION; PARTICLES; SALINE; LEAKS;
D O I
10.1259/dmfr.20130022
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The purpose of this study is to explore the topical use of radiographic contrast agents to enhance soft-tissue contrast on cone beam CT (CBCT) images. Different barium sulphate concentrations were first tested using an airway phantom. Different methods of barium sulphate application (nasal drops, syringe, spray and sinus wash) were then tested on four volunteers, and nebulized iodine was tested in one volunteer. CBCT images were performed and then assessed subjectively by two examiners for contrast agent uniformity and lack of streak artefact. 25.0% barium sulphate presented adequate viscosity and radiodensity. Barium sulphate administered via nasal drops and sprays showed non-uniform collection at the nostrils, along the inferior and/or middle nasal meatuses and posterior nasal choana. The syringe and sinus wash showed similar results with larger volumes collecting in the naso-oropharynx. Nebulized iodine failed to distribute into the nasal cavity and scarcely collected at the nostrils. All methods of nasal application failed to adequately reach or uniformly coat the nasal cavity beyond the inferior nasal meatuses. The key factors to consider for optimum topical radiographic contrast in the nasal airway are particle size, flow velocity and radio-opacity.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Synchrotron inline phase contrast μCT enables detailed virtual histology of embedded soft-tissue samples with and without staining
    Saccomano, Mara
    Albers, Jonas
    Tromba, Giuliana
    Radmilovic, Marina Dobrivojevic
    Gajovic, Srecko
    Alves, Frauke
    Dullin, Christian
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 1153 - 1161
  • [32] Soft-tissue detectability limits in cone-beam CT: 2AFC tests of human observer performance in relation to contrast, spatial resolution, and the 3D noise-power spectrum
    Siewerdsen, J.
    Tward, D.
    Daly, M.
    Paul, N.
    MEDICAL PHYSICS, 2006, 33 (06) : 2267 - 2267
  • [33] Soft tissue visualization using a highly efficient megavoltage Cone Beam CT imaging system
    Ghelmansarai, F
    Bani-Hashemi, A
    Pouliot, J
    Calderon, E
    Hernandez, P
    Mitschke, M
    Aubin, M
    Bucci, K
    MEDICAL PHYSICS, 2005, 32 (06) : 2131 - 2131
  • [34] Soft tissue visualization using a highly efficient megavoltage cone beam CT imaging system
    Ghelmansarai, FA
    Bani-Hashemi, A
    Pouliot, J
    Calderon, E
    Hernandez, P
    Mitschke, M
    Aubin, M
    Bucci, K
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 159 - 170
  • [35] Design and Construction of a Micro-focus In-line Phase-contrast Cone Beam CT (PC-CBCT) System for Soft Tissue Imaging
    Cai, Weixing
    Ning, Ruola
    MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING, 2010, 7622
  • [36] Dimensional Changes of Fresh Sockets With Reactive Soft Tissue Preservation: A Cone Beam CT Study
    Crespi, Roberto
    Cappare, Paolo
    Crespi, Giovanni
    Gastaldi, Giorgio
    Gherlone, Enrico Felice
    IMPLANT DENTISTRY, 2017, 26 (03) : 417 - 422
  • [37] Improved middle-ear soft-tissue visualization using synchrotron radiation phase-contrast imaging
    Elfarnawany, Mai
    Rohani, Seyed Alireza
    Ghomashchi, Soroush
    Allen, Daniel G.
    Zhu, Ning
    Agrawal, Sumit K.
    Ladak, Hanif M.
    HEARING RESEARCH, 2017, 354 : 1 - 8
  • [38] Performance Evaluation of a Differential Phase-contrast Cone-beam (DPC-CBCT) System for Soft Tissue Imaging
    Yu, Yang
    Ning, Ruola
    Cai, Weixing
    MEDICAL IMAGING 2011: PHYSICS OF MEDICAL IMAGING, 2011, 7961
  • [39] Soft-tissue detectability in cone-beam CT: Evaluation by 2AFC tests in relation to physical performance metrics
    Tward, D. J.
    Siewerdsen, J. H.
    Daly, M. J.
    Richard, S.
    Moseley, D. J.
    Jaffray, D. A.
    Paul, N. S.
    MEDICAL PHYSICS, 2007, 34 (11) : 4459 - 4471
  • [40] Upper airway dimensions and craniofacial morphology: A correlation study using cone beam computed tomography
    de Carvalho, Ana Rita da Rocha Martins
    Pollmann, Maria Cristina Figueiredo
    Martins, Eugenio Joaquim Pereira
    KOREAN JOURNAL OF ORTHODONTICS, 2024, 54 (05) : 274 - 283