Virtual Colon Tagging for Electronic Cleansing in Dual-energy Fecal-tagging CT Colonography

被引:0
|
作者
Cai, Wenli [1 ]
Kim, Se Hyung
Lee, June-Goo [1 ]
Yoshida, Hiroyuki [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
COMPUTED-TOMOGRAPHY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Partial volume effect (PVE) and tagging inhomogeneity are two major causes of artifacts in electronic cleansing (EC) for fecal-tagging CT colonography (CTC). Our purpose was to develop a novel method called "virtual tagging" for electronic cleansing in dual-energy fecal-tagging CTC. A three-material decomposition scheme was first applied in dual-energy CTC to decompose each voxel into a mixture of air, soft tissue, and iodine-tagged fecal material. The entire colonic lumen was then marked by virtually tagging the mixture portion of luminal air at each voxel. As a result, colon lumen including air and tagged materials was segmented and subtracted by their high values in virtually tagged images. Our virtual tagging scheme provides a cleansed colon that is free from artifacts caused by the PVE at air-tagging mixture and inhomogeneous tagging.
引用
收藏
页码:3736 / 3739
页数:4
相关论文
共 50 条
  • [31] Deep multi-spectral ensemble learning for electronic cleansing in dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Kim, Se Hyung
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2017: COMPUTER-AIDED DIAGNOSIS, 2017, 10134
  • [32] Self-supervised generative adversarial network for electronic cleansing in dual-energy CT colonography
    Tachibana, Rie
    Nappi, Janne J.
    Hironaka, Toru
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2020: IMAGING INFORMATICS FOR HEALTHCARE, RESEARCH, AND APPLICATIONS, 2020, 11318
  • [33] Electronic cleansing and stool tagging in CT colonography: Advantages and pitfalls with primary three-dimensional evaluation
    Pickhardt, PJ
    Choi, JHR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 181 (03) : 799 - 805
  • [34] Dietary fecal tagging as a cleansing method before CT colonography: Initial results-polyp detection and patient acceptance
    Lefere, PA
    Gryspeerdt, SS
    Dewyspelaere, J
    Baekelandt, M
    Van Holsbeeck, BG
    RADIOLOGY, 2002, 224 (02) : 393 - 403
  • [35] Dual-Energy CT for Diagnostic CT Colonography
    Karcaaltincaba, Musturay
    Ozdeniz, Ilknur
    RADIOGRAPHICS, 2014, 34 (03) : 847 - 847
  • [36] Fecal tagging: A new strategy to obviate bowel cleansing before virtual colonoscopy
    Lauenstein, TC
    Debatin, JF
    Gerken, G
    Holtmann, G
    GASTROINTESTINAL ENDOSCOPY, 2002, 55 (05) : AB210 - AB210
  • [37] Technical development: CT colonography without cathartic cleansing and with barium as the sole tagging agent
    Lefere, P
    Gryspeerdt, S
    Baekelandt, M
    Van Holsbeeck, B
    Ziekenhuis, S
    MEDICAL IMAGING 2004: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2004, 5 (23): : 259 - 267
  • [38] Electronic colon-cleansing for CT colonography: diagnostic performance
    Juchems, Markus S.
    Ernst, Andrea
    Johnson, Peter
    Virmani, Sunny
    Brambs, Hans-Juergen
    Aschoff, Andrik J.
    ABDOMINAL IMAGING, 2009, 34 (03): : 359 - 364
  • [39] Electronic colon-cleansing for CT colonography: diagnostic performance
    Markus S. Juchems
    Andrea Ernst
    Peter Johnson
    Sunny Virmani
    Hans-Juergen Brambs
    Andrik J. Aschoff
    Abdominal Imaging, 2009, 34 : 359 - 364
  • [40] Full-laxative Versus Minimum-laxative Fecal-tagging CT Colonography Using 64-detector Row CT: Prospective Blinded Comparison of Diagnostic Performance, Tagging Quality, and Patient Acceptance
    Nagata, Koichi
    Okawa, Tomohiko
    Honma, Akihiro
    Endo, Shungo
    Kudo, Shin-ei
    Yoshida, Hiroyuki
    ACADEMIC RADIOLOGY, 2009, 16 (07) : 780 - 789