Virtual Colon Tagging for Electronic Cleansing in Dual-energy Fecal-tagging CT Colonography

被引:0
|
作者
Cai, Wenli [1 ]
Kim, Se Hyung
Lee, June-Goo [1 ]
Yoshida, Hiroyuki [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Radiol, Boston, MA 02114 USA
关键词
COMPUTED-TOMOGRAPHY;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Partial volume effect (PVE) and tagging inhomogeneity are two major causes of artifacts in electronic cleansing (EC) for fecal-tagging CT colonography (CTC). Our purpose was to develop a novel method called "virtual tagging" for electronic cleansing in dual-energy fecal-tagging CTC. A three-material decomposition scheme was first applied in dual-energy CTC to decompose each voxel into a mixture of air, soft tissue, and iodine-tagged fecal material. The entire colonic lumen was then marked by virtually tagging the mixture portion of luminal air at each voxel. As a result, colon lumen including air and tagged materials was segmented and subtracted by their high values in virtually tagged images. Our virtual tagging scheme provides a cleansed colon that is free from artifacts caused by the PVE at air-tagging mixture and inhomogeneous tagging.
引用
收藏
页码:3736 / 3739
页数:4
相关论文
共 50 条
  • [21] Deep Learning Electronic Cleansing for Single- and Dual-Energy CT Colonography
    Tachibana, Rie
    Nappi, Janne J.
    Ota, Junko
    Kohlhase, Nadja
    Hironaka, Toru
    Kim, Se Hyung
    Regge, Daniele
    Yoshida, Hiroyuki
    RADIOGRAPHICS, 2018, 38 (07) : 2034 - 2050
  • [22] A New Algorithm of Electronic Cleansing for Weak Faecal-Tagging CT Colonography
    Lu, Le
    Jian, Bing
    Wu, Dijia
    Wolf, Matthias
    MACHINE LEARNING IN MEDICAL IMAGING (MLMI 2013), 2013, 8184 : 57 - 65
  • [23] Deep-Cleansing: Deep-Learning Based Electronic Cleansing in Dual-Energy CT Colonography
    Luo, Guibo
    Liu, Tianyu
    Li, Bin
    Zalis, Michael
    Cai, Wenli
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2021, PT VII, 2021, 12907 : 43 - 53
  • [24] Digital Bowel Cleansing Free Colonic Polyp Detection Method for Fecal Tagging CT Colonography
    Oda, Masahiro
    Kitasaka, Takayuki
    Mori, Kensaku
    Suenaga, Yasuhito
    Takayama, Tetsuji
    Takabatake, Hirotsugu
    Mori, Masaki
    Natori, Hiroshi
    Nawano, Shigeru
    ACADEMIC RADIOLOGY, 2009, 16 (04) : 486 - 494
  • [25] Dual-energy electronic cleansing for non-cathartic CT Colonography: a phantom study
    Cai, Wenli
    Liu, Bob
    Yoshida, Hiroyuki
    MEDICAL IMAGING 2010: COMPUTER - AIDED DIAGNOSIS, 2010, 7624
  • [26] CT colonography with fecal tagging after incomplete colonoscopy
    S. Gryspeerdt
    P. Lefere
    M. Herman
    R. Deman
    L. Rutgeerts
    G. Ghillebert
    F. Baert
    M. Baekelandt
    B. Van Holsbeeck
    European Radiology, 2005, 15 : 1192 - 1202
  • [27] CT colonography with fecal tagging after incomplete colonoscopy
    Gryspeerdt, S
    Lefere, P
    Herman, M
    Deman, R
    Rutgeerts, L
    Ghillebert, G
    Baert, F
    Baekelandt, M
    Van Holsbeeck, B
    EUROPEAN RADIOLOGY, 2005, 15 (06) : 1192 - 1202
  • [28] Comparative Evaluation of the Fecal-Tagging Quality in CT Colonography: Barium vs. Iodinated Oral Contrast Agent
    Nagata, Koichi
    Singh, Anand Kumar
    Sangwaiya, Minal Jagtiani
    Naeppi, Janne
    Zalis, Michael E.
    Cai, Wenli
    Yoshida, Hiroyuki
    ACADEMIC RADIOLOGY, 2009, 16 (11) : 1393 - 1399
  • [29] CT colonography: patient tolerance of laxative free fecal tagging regimen versus traditional cathartic cleansing
    Duccio Buccicardi
    Massimo Grosso
    Ilaria Caviglia
    Alessandro Gastaldo
    Sabrina Carbone
    Emanuele Neri
    Carlo Bartolozzi
    Piergiorgio Quadri
    Abdominal Imaging, 2011, 36 : 532 - 537
  • [30] CT colonography: patient tolerance of laxative free fecal tagging regimen versus traditional cathartic cleansing
    Buccicardi, Duccio
    Grosso, Massimo
    Caviglia, Ilaria
    Gastaldo, Alessandro
    Carbone, Sabrina
    Neri, Emanuele
    Bartolozzi, Carlo
    Quadri, Piergiorgio
    ABDOMINAL IMAGING, 2011, 36 (05): : 532 - 537