Determination of the seismic performance factors for post-tensioned rocking timber wall systems

被引:32
|
作者
Sarti, Francesco [1 ]
Palermo, Alessandro [2 ]
Pampanin, Stefano [1 ]
Berman, Jeffrey [3 ]
机构
[1] Univ Canterbury, Civil & Nat Resources Engn, Christchurch, New Zealand
[2] Univ Canterbury, Dept Civil & Nat Resources Engn, Christchurch, New Zealand
[3] Univ Washington, Civil & Environm Engn, Seattle, WA 98195 USA
来源
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS | 2017年 / 46卷 / 02期
关键词
post-tensioned timber; timber structures; FEMA p-695; DUCTILE CONNECTIONS; FRAMES; BEHAVIOR;
D O I
10.1002/eqe.2784
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Post-tensioned technologies for concrete seismic resistant buildings were first developed in the 1990s during the PREcast Seismic Structural Systems program. Among different solutions, the hybrid system proved to be the most resilient solution providing a combination of re-centering and energy dissipative contributions respectively by using post-tensioned tendons and mild steel reinforcement. The system, while providing significant strength and energy dissipation, reduces structural element damage and limits post-earthquake residual displacements. More recently, the technology was extended to laminated veneer lumber (LVL) structural members, and extensive experimental and numerical work was carried out and allowed the development of reliable analytical and numerical models as well as design guidelines. On the basis of the experimental and numerical outcomes, this paper presents the evaluation of the seismic performance factors for post-tensioned rocking LVL walls using the FEMA P-695 procedure. Several archetype buildings were designed considering different parameters such as the building and story height, the type of seismic resistant system, the magnitude of gravity loads and the seismic design category. Lumped plasticity models were developed for each index archetype to simulate the behavioral aspects and collapse mechanisms. Non-linear quasi-static analyses were carried out to evaluate the system over-strength factor; moreover, non-linear time history analyses were performed using the incremental dynamic analysis concept to assess the collapse of each building. From the results of quasi-static and dynamic analyses the response modification factor, R, system over-strength factor, (0), and deflection amplification factor, C-d, values of, respectively, 7, 3.5 and 7.5 are recommended. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:181 / 200
页数:20
相关论文
共 50 条
  • [31] Seismic performance of interior post-tensioned concrete wide beams
    Siah, WL
    Mendis, P
    Stehle, JS
    ACI STRUCTURAL JOURNAL, 2003, 100 (03) : 283 - 290
  • [32] Seismic performance assessment of conventional CLT shear wall structures and post-tensioned CLT shear wall structures
    Sun, Xiaofeng
    He, Minjuan
    Li, Zheng
    Lam, Frank
    ENGINEERING STRUCTURES, 2019, 196
  • [33] Seismic Design and Performance Assessment of the Post-tensioned Bridge Piers
    Shen, Yu
    Freddi, Fabio
    Li, Jianzhong
    Li, Yongxing
    SEISMIC ISOLATION, ENERGY DISSIPATION AND ACTIVE VIBRATION CONTROL OF STRUCTURES, 17WCSI 2022, 2023, 309 : 438 - 446
  • [34] Theoretical and experimental research on the rocking truss system with post-tensioned rocking connection
    Yang, Xian-Lin
    Jia, Ming-Ming
    Lu, Da-Gang
    Cui, Chang-Yu
    JOURNAL OF BUILDING ENGINEERING, 2024, 95
  • [35] Hybrid simulation of a post-tensioned timber frame and validation of numerical models for seismic design
    Ogrizovic, J.
    Abbiati, G.
    Stojadinovic, B.
    Frangi, A.
    ENGINEERING STRUCTURES, 2022, 265
  • [36] Seismic loss analysis of buildings with post-tensioned cross-laminated timber walls
    Wilson, Alex W.
    Phillips, Adam R.
    Motter, Christopher J.
    Lee, Ji Y.
    Dolan, J. Daniel
    EARTHQUAKE SPECTRA, 2021, 37 (01) : 324 - 345
  • [37] Rocking spectrum of a post-tensioned double-column rocking bridge system
    Wang B.
    Shi Y.
    Shi X.
    Zhang H.
    Zhendong yu Chongji/Journal of Vibration and Shock, 2022, 41 (10): : 270 - 277
  • [38] Numerical Investigation of the Seismic-Induced Rocking Behavior of Unbonded Post-Tensioned Bridge Piers
    Bao, Zehua
    Xu, Wenjing
    Gao, Haoyuan
    Zhong, Xueqi
    Li, Jianzhong
    BUILDINGS, 2024, 14 (06)
  • [39] Seismic Performance of Steel Frame Systems with Post-Tensioned Jointed Rocking Connections with Replaceable Structural Fuses Subjected to Mainshock-Aftershock Sequences
    Tatar, Arman
    Dowden, Daniel M.
    STRUCTURES CONGRESS 2020, 2020, : 475 - 486
  • [40] BEHAVIOUR OF POST-TENSIONED TIMBER COLUMNS UNDER BI-DIRECTIONAL SEISMIC LOADING
    Iqbal, Asif
    Pampanin, Stefano
    Palermo, Alessandro
    Buchanan, Andrew H.
    BULLETIN OF THE NEW ZEALAND SOCIETY FOR EARTHQUAKE ENGINEERING, 2014, 47 (01): : 41 - 53