Determination of the seismic performance factors for post-tensioned rocking timber wall systems

被引:32
|
作者
Sarti, Francesco [1 ]
Palermo, Alessandro [2 ]
Pampanin, Stefano [1 ]
Berman, Jeffrey [3 ]
机构
[1] Univ Canterbury, Civil & Nat Resources Engn, Christchurch, New Zealand
[2] Univ Canterbury, Dept Civil & Nat Resources Engn, Christchurch, New Zealand
[3] Univ Washington, Civil & Environm Engn, Seattle, WA 98195 USA
来源
EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS | 2017年 / 46卷 / 02期
关键词
post-tensioned timber; timber structures; FEMA p-695; DUCTILE CONNECTIONS; FRAMES; BEHAVIOR;
D O I
10.1002/eqe.2784
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Post-tensioned technologies for concrete seismic resistant buildings were first developed in the 1990s during the PREcast Seismic Structural Systems program. Among different solutions, the hybrid system proved to be the most resilient solution providing a combination of re-centering and energy dissipative contributions respectively by using post-tensioned tendons and mild steel reinforcement. The system, while providing significant strength and energy dissipation, reduces structural element damage and limits post-earthquake residual displacements. More recently, the technology was extended to laminated veneer lumber (LVL) structural members, and extensive experimental and numerical work was carried out and allowed the development of reliable analytical and numerical models as well as design guidelines. On the basis of the experimental and numerical outcomes, this paper presents the evaluation of the seismic performance factors for post-tensioned rocking LVL walls using the FEMA P-695 procedure. Several archetype buildings were designed considering different parameters such as the building and story height, the type of seismic resistant system, the magnitude of gravity loads and the seismic design category. Lumped plasticity models were developed for each index archetype to simulate the behavioral aspects and collapse mechanisms. Non-linear quasi-static analyses were carried out to evaluate the system over-strength factor; moreover, non-linear time history analyses were performed using the incremental dynamic analysis concept to assess the collapse of each building. From the results of quasi-static and dynamic analyses the response modification factor, R, system over-strength factor, (0), and deflection amplification factor, C-d, values of, respectively, 7, 3.5 and 7.5 are recommended. Copyright (c) 2016 John Wiley & Sons, Ltd.
引用
收藏
页码:181 / 200
页数:20
相关论文
共 50 条
  • [11] Modeling techniques for post-tensioned cross-laminated timber rocking walls
    Wilson, Alex W.
    Motter, Christopher J.
    Phillips, Adam R.
    Dolan, J. Daniel
    ENGINEERING STRUCTURES, 2019, 195 : 299 - 308
  • [12] Seismic vulnerability assessment of post-tensioned timber building fitted with dissipative bracing systems
    Odikamnoro, Ikenna Harold
    Badal, Prakash S.
    Tesfamariam, Solomon
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2024, 51 (07) : 740 - 752
  • [13] Nonlinear analytical modeling of mass-timber buildings with post-tensioned rocking walls
    Aloisio, Angelo
    Rosso, Marco Martino
    Huang, Da
    Iqbal, Asif
    Fragiacomo, Massimo
    Pei, Shiling
    BULLETIN OF EARTHQUAKE ENGINEERING, 2023, 21 (01) : 473 - 502
  • [14] Experimental Seismic Response of a Resilient 2-Story Mass-Timber Building with Post-Tensioned Rocking Walls
    Pei, Shiling
    van de Lindt, John W.
    Barbosa, Andre R.
    Berman, Jeffrey W.
    McDonnell, Eric
    Dolan, J. Daniel
    Blomgren, Hans-Erik
    Zimmerman, Reid B.
    Huang, Da
    Wichman, Sarah
    JOURNAL OF STRUCTURAL ENGINEERING, 2019, 145 (11)
  • [15] Displacement based design of post-tensioned timber framed buildings with dissipative rocking mechanism
    Di Cesare, Antonio
    Ponzo, Felice Carlo
    Pampanin, Stefano
    Smith, Tobias
    Nigro, Domenico
    Lamarucciola, Nicla
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2019, 116 : 317 - 330
  • [16] Simplified Dynamic Model for Post-tensioned Cross-laminated Timber Rocking Walls
    Pei, S.
    Huang, D.
    Berman, J. W.
    Wichman, S. K.
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2021, 50 (03): : 845 - 862
  • [17] Nonlinear analytical modeling of mass-timber buildings with post-tensioned rocking walls
    Angelo Aloisio
    Marco Martino Rosso
    Da Huang
    Asif Iqbal
    Massimo Fragiacomo
    Shiling Pei
    Bulletin of Earthquake Engineering, 2023, 21 : 473 - 502
  • [18] Seismic Performance of Full-Scale Post-Tensioned Timber Beam-Column Connections
    Iqbal, Asif
    Pampanin, Stefano
    Buchanan, Andrew H.
    JOURNAL OF EARTHQUAKE ENGINEERING, 2016, 20 (03) : 383 - 405
  • [19] An explicit analytical model for seismic performance of an unbonded post-tensioned precast segmental rocking hollow pier
    Wang, Zhen
    Wang, Jing-Quan
    Liu, Tong-Xu
    Zhang, Jian
    ENGINEERING STRUCTURES, 2018, 161 : 176 - 191
  • [20] The Dynamics of Precast Post-Tensioned Rocking Columns
    Zhang, Qi
    Alam, M. Shahria
    STRUCTURES CONGRESS 2018: BRIDGES, TRANSPORTATION STRUCTURES, AND NONBUILDING STRUCTURES, 2018, : 349 - 358