Dynamic CT myocardial perfusion imaging

被引:29
|
作者
Caruso, Damiano [1 ,2 ]
Eid, Marwen [1 ]
Schoepf, U. Joseph [1 ,3 ]
Jin, Kwang Nam [1 ,4 ]
Varga-Szemes, Akos [1 ]
Tesche, Christian [1 ,5 ]
Mangold, Stefanie [1 ,6 ]
Spandorfer, Adam [1 ]
Laghi, Andrea [2 ]
De Cecco, Carlo N. [1 ]
机构
[1] Med Univ South Carolina, Dept Radiol & Radiol Sci, Div Cardiovasc Imaging, Charleston, SC 29425 USA
[2] Univ Rome Sapienza, Dept Radiol Sci Oncol & Pathol Sci, Latina, Italy
[3] Med Univ South Carolina, Dept Med, Div Cardiol, Charleston, SC 29425 USA
[4] Seoul Metropolitan Govt Seoul Natl Univ, Boramae Med Ctr, Dept Radiol, Seoul, South Korea
[5] Heart Ctr Munich Bogenhausen, Dept Cardiol & Intens Care Med, Munich, Germany
[6] Univ Hosp Tuebingen, Dept Diagnost & Intervent Radiol, Tubingen, Germany
关键词
Myocardial perfusion imaging; Computed tomography; Dynamic CT myocardial perfusion; Coronary artery disease; CORONARY-ARTERY-DISEASE; EMISSION COMPUTED-TOMOGRAPHY; DUAL-ENERGY CT; GLOBAL QUANTIFICATION; DIAGNOSTIC-ACCURACY; MAGNETIC-RESONANCE; STRESS; STENOSIS; FLOW; INTERVENTION;
D O I
10.1016/j.ejrad.2016.07.017
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Non-invasive cardiac imaging has rapidly evolved during the last decade due to advancements in CT based technologies. Coronary CT angiography has been shown to reliably assess coronary anatomy and detect high risk coronary artery disease. However, this technique is limited to anatomical assessment, thus non-invasive techniques for functional assessment of the heart are necessary. CT myocardial perfusion is a new CT based technique that provides functional assessment of the myocardium and allows for a comprehensive assessment of coronary artery disease with a single modality when combined with CTA. This review aims to discuss dynamic CT myocardial perfusion as a new technique in the assessment of CAD. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:1893 / 1899
页数:7
相关论文
共 50 条
  • [41] Low dose dynamic CT myocardial perfusion imaging using a statistical iterative reconstruction method
    Tao, Yinghua
    Chen, Guang-Hong
    Hacker, Timothy A.
    Raval, Amish N.
    Van Lysel, Michael S.
    Speidel, Michael A.
    [J]. MEDICAL PHYSICS, 2014, 41 (07)
  • [42] Dynamic CT myocardial perfusion imaging identifies early perfusion abnormalities in diabetes and hypertension: Insights from a multicenter registry
    Vliegenthart, Rozemarijn
    De Cecco, Carlo N.
    Wichmann, Julian L.
    Meinel, Felix G.
    Pelgrim, Gert Jan
    Tesche, Christian
    Ebersberger, Ullrich
    Pugliese, Francesca
    Bamberg, Fabian
    Choe, Yeon Hyeon
    Wang, Yining
    Schoepf, U. Joseph
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2016, 10 (04) : 301 - 308
  • [43] FFR-CT and CT Myocardial Perfusion Imaging Friends or Foes?
    Schoepf, U. Joseph
    van Assen, Marly
    [J]. JACC-CARDIOVASCULAR IMAGING, 2019, 12 (12) : 2472 - 2474
  • [44] ADENOSINE COMBINED WITH DYNAMIC EXERCISE FOR MYOCARDIAL PERFUSION IMAGING
    PENNELL, DJ
    MAVROGENI, SI
    FORBAT, SM
    KARWATOWSKI, SP
    UNDERWOOD, SR
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 25 (06) : 1300 - 1309
  • [45] A Novel Porcine Model of Acute Myocardial Ischemia Guided by FFR for Accuracy of Dynamic CT Myocardial Perfusion Imaging Study
    Zhou, Xiaorong
    Rosenthal, Noah
    Parikh, Sahil A.
    Okere, Isidore
    Rajiah, Prabhakar
    Wilson, David
    Bezerra, Hiram G.
    [J]. CIRCULATION, 2013, 128 (22)
  • [46] Diagnostic Accuracy of Quantification Myocardial Perfusion Ratio Derived From Dynamic CT Perfusion Imaging for Detection of Functionally Significant Stenosis
    Uetani, Teruyoshi
    Kido, Teruhito
    Nakao, Yasuhisa
    Akazawa, Yusuke
    Kinoshita, Masaki
    Seike, Fumiyasu
    Sasaki, Yasuhiro
    Higashi, Haruhiko
    Fujii, Akira
    Aono, Jun
    Nagai, Takayuki
    Nishimura, Kazuhisa
    Inoue, Katsuji
    Ikeda, Shuntaro
    Yamaguchi, Osamu
    [J]. CIRCULATION, 2018, 138
  • [47] Static Myocardial Perfusion Imaging using denoised dynamic Rb-82 PET/CT scans
    Petersen, M. N. M.
    Hoff, C. M.
    Harms, H. J.
    Bouchelouche, K.
    Sorensen, J.
    Tolbod, L. P.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2015, 42 : S841 - S841
  • [48] Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model
    Scherer, Kai
    Hammel, Johannes
    Sellerer, Thorsten
    Mechlem, Korbinian
    Renger, Bernhard
    Baehr, Andrea
    Kupatt, Christian
    Hinkel, Rabea
    Herzen, Julia
    Pfeiffer, Franz
    Rummeny, Ernst
    Pfeiffer, Daniela
    [J]. SCIENTIFIC REPORTS, 2019, 9 (1)
  • [49] Effect of Cardiac Phase on Cardiac Output Index Derived from Dynamic CT Myocardial Perfusion Imaging
    Dempsey, Sergio C. H.
    Lee, Ting-Yim
    Samani, Abbas
    So, Aaron
    [J]. TOMOGRAPHY, 2022, 8 (02) : 1129 - 1140
  • [50] BEST IN PHYSICS (IMAGING): Dynamic CT Myocardial Perfusion Measurement and Its Comparison to Fractional Flow Reserve
    Ziemer, B.
    Hubbard, L.
    Groves, E.
    Sadeghi, B.
    Javan, H.
    Lipinski, J.
    Molloi, S.
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3633 - 3633