Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model

被引:6
|
作者
Scherer, Kai [1 ,2 ,3 ,4 ]
Hammel, Johannes [1 ,2 ,3 ,4 ]
Sellerer, Thorsten [3 ,4 ]
Mechlem, Korbinian [3 ,4 ]
Renger, Bernhard [1 ,2 ]
Baehr, Andrea [5 ,6 ]
Kupatt, Christian [5 ,6 ]
Hinkel, Rabea [5 ,6 ,7 ]
Herzen, Julia [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ,8 ]
Rummeny, Ernst [1 ,2 ]
Pfeiffer, Daniela [1 ,2 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
[3] Tech Univ Munich, Dept Phys, Chair Biomed Phys, D-85748 Garching, Germany
[4] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[5] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Innere Med 1, D-81675 Munich, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80802 Munich, Germany
[7] Deutsch Primatenzentrum GmbH, Leibniz Inst Primatenforsch, Dept Lab Anim Sci, D-37077 Gottingen, Germany
[8] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
关键词
CORONARY-ARTERY-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; ISCHEMIA;
D O I
10.1038/s41598-019-52458-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ischemic heart disease is the globally leading cause of death. When using coronary CT angiography, the functional hemodynamics within the myocardium remain uncertain. In this study myocardial CT perfusion imaging using iodine contrast agent demonstrated to strongly improve the assessment of myocardial disorders. However, a retrieval of such dynamics using Hounsfield units from conventional CT poses concerns with respect to beam-hardening effects and low contrast-to-noise ratio (CNR). Dual-energy CT offers novel approaches to overcome aforementioned limitations. Quantitative peak enhancement, perfusion, time to peak and iodine volume measurements inside the myocardium were determined resulting in 0.92 mg/ml, 0.085 mg/ml/s 17.12 s and 29.89 mg/ml*s, respectively. We report on the first extensive quantitative and iodine-based analysis of myocardial dynamics in a healthy porcine model using a dual-layer spectral CT. We further elucidate on the potential of reducing the radiation dose from 135 to 18 mGy and the contrast agent volume from 60 to 30 mL by presenting a two-shot acquisition approach and measuring iodine concentrations in the myocardium in-vivo down to 1 mg/ml, respectively. We believe that dynamic quantitative iodine perfusion imaging may be a highly sensitive tool for the precise functional assessment and monitoring of early myocardial ischemia.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [1] Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model
    Kai Scherer
    Johannes Hammel
    Thorsten Sellerer
    Korbinian Mechlem
    Bernhard Renger
    Andrea Bähr
    Christian Kupatt
    Rabea Hinkel
    Julia Herzen
    Franz Pfeiffer
    Ernst Rummeny
    Daniela Pfeiffer
    Scientific Reports, 9
  • [2] Iodine Imaging at Spectral CT with a Dual-Layer Detector
    Ozguner, O.
    Dhanantwari, A.
    Halliburton, S.
    Wen, G.
    Utrup, S.
    Jordan, D.
    MEDICAL PHYSICS, 2016, 43 (06) : 3657 - 3657
  • [3] Quantitative myocardial perfusion imaging in a porcine ischemia model using a prototype spectral detector CT system
    Fahmi, Rachid
    Eck, Brendan L.
    Levi, Jacob
    Fares, Anas
    Dhanantwari, Amar
    Vembar, Mani
    Bezerra, Hiram G.
    Wilson, David L.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (06): : 2407 - 2431
  • [4] Dynamic CT Myocardial Perfusion Imaging: Detection of Ischemia in a Porcine Model with FFR Verification
    Fahmi, Rachid
    Eck, Brendan L.
    Vembar, Mani
    Bezerra, Hiram G.
    Wilson, David L.
    MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2014, 9038
  • [5] Quantitative myocardial perfusion measurement using CT Perfusion: a validation study in a porcine model of reperfused acute myocardial infarction
    So, Aaron
    Hsieh, Jiang
    Li, Jian-Ying
    Hadway, Jennifer
    Kong, Hua-Fu
    Lee, Ting-Yim
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1237 - 1248
  • [6] Quantitative myocardial perfusion measurement using CT Perfusion: a validation study in a porcine model of reperfused acute myocardial infarction
    Aaron So
    Jiang Hsieh
    Jian-Ying Li
    Jennifer Hadway
    Hua-Fu Kong
    Ting-Yim Lee
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1237 - 1248
  • [7] Quantified dual energy computed tomography perfusion imaging using myocardial iodine concentration: Validation using CT derived myocardial blood flow and invasive fractional flow reserve in a porcine model
    Poulter, Rohan
    Wood, David A.
    Starovoytov, Andrew
    Smith, Stephanie
    Chitsaz, Mehran
    Mayo, John
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (02) : 86 - 91
  • [8] Dual-Layer Detector Spectral CT Performance: Quantitative Accuracy and Precision of Iodine Concentration Measurements
    Zhao, X.
    Hameed, T.
    Hutchins, G.
    Liang, Y.
    MEDICAL PHYSICS, 2017, 44 (06) : 3233 - 3233
  • [9] Dynamic CT myocardial perfusion imaging
    Nieman, Koen
    Balla, Sujana
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2020, 14 (04) : 303 - 306
  • [10] Dynamic CT myocardial perfusion imaging
    Caruso, Damiano
    Eid, Marwen
    Schoepf, U. Joseph
    Jin, Kwang Nam
    Varga-Szemes, Akos
    Tesche, Christian
    Mangold, Stefanie
    Spandorfer, Adam
    Laghi, Andrea
    De Cecco, Carlo N.
    EUROPEAN JOURNAL OF RADIOLOGY, 2016, 85 (10) : 1893 - 1899