Dynamic Quantitative Iodine Myocardial Perfusion Imaging with Dual-Layer CT using a Porcine Model

被引:6
|
作者
Scherer, Kai [1 ,2 ,3 ,4 ]
Hammel, Johannes [1 ,2 ,3 ,4 ]
Sellerer, Thorsten [3 ,4 ]
Mechlem, Korbinian [3 ,4 ]
Renger, Bernhard [1 ,2 ]
Baehr, Andrea [5 ,6 ]
Kupatt, Christian [5 ,6 ]
Hinkel, Rabea [5 ,6 ,7 ]
Herzen, Julia [3 ,4 ]
Pfeiffer, Franz [1 ,2 ,3 ,4 ,8 ]
Rummeny, Ernst [1 ,2 ]
Pfeiffer, Daniela [1 ,2 ]
机构
[1] Tech Univ Munich, Sch Med, Dept Diagnost & Intervent Radiol, D-81675 Munich, Germany
[2] Tech Univ Munich, Klinikum Rechts Isar, D-81675 Munich, Germany
[3] Tech Univ Munich, Dept Phys, Chair Biomed Phys, D-85748 Garching, Germany
[4] Tech Univ Munich, Munich Sch BioEngn, D-85748 Garching, Germany
[5] Tech Univ Munich, Klinikum Rechts Isar, Klin & Poliklin Innere Med 1, D-81675 Munich, Germany
[6] DZHK German Ctr Cardiovasc Res, Partner Site Munich Heart Alliance, D-80802 Munich, Germany
[7] Deutsch Primatenzentrum GmbH, Leibniz Inst Primatenforsch, Dept Lab Anim Sci, D-37077 Gottingen, Germany
[8] Tech Univ Munich, Inst Adv Study, D-85748 Garching, Germany
关键词
CORONARY-ARTERY-DISEASE; ENERGY CT; COMPUTED-TOMOGRAPHY; ANGIOGRAPHY; ISCHEMIA;
D O I
10.1038/s41598-019-52458-1
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Ischemic heart disease is the globally leading cause of death. When using coronary CT angiography, the functional hemodynamics within the myocardium remain uncertain. In this study myocardial CT perfusion imaging using iodine contrast agent demonstrated to strongly improve the assessment of myocardial disorders. However, a retrieval of such dynamics using Hounsfield units from conventional CT poses concerns with respect to beam-hardening effects and low contrast-to-noise ratio (CNR). Dual-energy CT offers novel approaches to overcome aforementioned limitations. Quantitative peak enhancement, perfusion, time to peak and iodine volume measurements inside the myocardium were determined resulting in 0.92 mg/ml, 0.085 mg/ml/s 17.12 s and 29.89 mg/ml*s, respectively. We report on the first extensive quantitative and iodine-based analysis of myocardial dynamics in a healthy porcine model using a dual-layer spectral CT. We further elucidate on the potential of reducing the radiation dose from 135 to 18 mGy and the contrast agent volume from 60 to 30 mL by presenting a two-shot acquisition approach and measuring iodine concentrations in the myocardium in-vivo down to 1 mg/ml, respectively. We believe that dynamic quantitative iodine perfusion imaging may be a highly sensitive tool for the precise functional assessment and monitoring of early myocardial ischemia.
引用
下载
收藏
页数:9
相关论文
共 50 条
  • [31] Quantitative calcium-based assessment of osteoporosis in dual-layer spectral CT
    Do, T. D.
    Rahn, S.
    Melzig, C.
    Heussel, C. P.
    Stiller, W.
    Kauczor, H. U.
    Weber, T. F.
    Skornitzke, S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2024, 178
  • [32] Quantitative and qualitative assessment of plasma cell dyscrasias in dual-layer spectral CT
    Brandelik, S. C.
    Skornitzke, S.
    Mokry, T.
    Sauer, S.
    Stiller, W.
    Nattenmuller, J.
    Kauczor, H. U.
    Weber, T. F.
    Do, T. D.
    EUROPEAN RADIOLOGY, 2021, 31 (10) : 7664 - 7673
  • [33] Dynamic Myocardial CT Perfusion Imaging for Evaluation of Myocardial Ischemia as Determined by MR Imaging
    Bamberg, Fabian
    Marcus, Roy P.
    Becker, Alexander
    Hildebrandt, Kristof
    Bauner, Kerstin
    Schwarz, Florian
    Greif, Martin
    von Ziegler, Franz
    Bischoff, Bernhard
    Becker, Hans-Christoph
    Johnson, Thorsten R.
    Reiser, Maximilian F.
    Nikolaou, Konstantin
    Theisen, Daniel
    JACC-CARDIOVASCULAR IMAGING, 2014, 7 (03) : 267 - 277
  • [34] Dynamic path planning by using dual-layer fuzzy controllers
    Lei, Yanmin
    Zhu, Qidan
    Guan, Xiuli
    Feng, Zhibin
    Huazhong Keji Daxue Xuebao (Ziran Kexue Ban)/Journal of Huazhong University of Science and Technology (Natural Science Edition), 2011, 39 (09): : 57 - 61
  • [35] DUAL - ENERGY CT MYOCARDIAL PERFUSION IMAGING OF VASODIALATOR INDUCED MYOCARDIAL ISCHEMIA
    Sidhu, M.
    Uthamalingam, S.
    Engel, L.
    Lee, A. M.
    Ghoshhajra, B.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2015, 63 (04) : 664 - 664
  • [36] Quantitative rest/stress myocardial perfusion imaging with dynamic SPECT
    Reutter, Bryan
    Botvinick, Elias
    Boutchko, Rostyslav
    Huesman, Ronald
    Gullberg, Grant
    JOURNAL OF NUCLEAR MEDICINE, 2010, 51
  • [37] Dynamic evaluation of myocardial extracellular volume fraction using dual-layer spectral detector computed tomography
    Kidoh, Masafumi
    Oda, Seitaro
    Takashio, Seiji
    Tsujita, Kenichi
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2020, 4 (06)
  • [38] Repeatability of myocardial flow reserve measurement using quantitative dynamic SPECT perfusion imaging
    Bailly, M.
    Thibault, F.
    Metrard, G.
    Courtehoux, M.
    Angoulvant, D.
    Ribeiro, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2022, 49 (SUPPL 1) : S139 - S139
  • [39] Dynamic myocardial CT perfusion imaging-state of the art
    Sliwicka, Olga
    Sechopoulos, Ioannis
    Baggiano, Andrea
    Pontone, Gianluca
    Nijveldt, Robin
    Habets, Jesse
    EUROPEAN RADIOLOGY, 2023, 33 (08) : 5509 - 5525
  • [40] Accuracy of Electron Density, Effective Atomic Number, and Iodine Concentration Determination with Dual-Layer CT
    Hua, C.
    Shapira, N.
    Merchant, T.
    Klahr, P.
    Yagil, Y.
    MEDICAL PHYSICS, 2018, 45 (06) : E588 - E588