Magnetic Cu: CuO-GO nanocomposite for efficient dispersive micro-solid phase extraction of polycyclic aromatic hydrocarbons from vegetable, fruit, and environmental water samples by liquid chromatographic determination

被引:76
|
作者
Asfaram, Arash [1 ]
Dil, Ebrahim Alipanahpour [2 ]
Arabkhani, Payam [3 ]
Sadeghfar, Fardin [4 ]
Ghaedi, Mehrorang [2 ]
机构
[1] Yasuj Univ Med Sci, Med Plants Res Ctr, Yasuj, Iran
[2] Univ Yasuj, Dept Chem, Yasuj 7591874831, Iran
[3] Islamic Azad Univ, Dept Chem, Tehran North Branch, Tehran, Iran
[4] Univ Zanjan, Fac Sci, Dept Phys, POB 45371-38791, Zanjan, Iran
关键词
Experimental design; Food and environmental samples; Fe3O4/Cu; CuO/GO-NC; MD-mu-SPE; Polycyclic aromatic hydrocarbons (PAHs); Sample preparation; GRAPHENE OXIDE NANOCOMPOSITE; HUMAN URINE SAMPLES; AQUEOUS-SOLUTIONS; MICROEXTRACTION; NANOPARTICLES; PRECONCENTRATION; COMPOSITE; DESIGN; CARBON; FUNCTIONALIZATION;
D O I
10.1016/j.talanta.2020.121131
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this research, we presented a magnetic dispersive micro-solid phase extraction (MD-mu-SPE) method coupled with high performance liquid chromatography (HPLC) based on the use of magnetic Cu: CuO-Graphene Oxide (GO) nanocomposite (Fe3O4/Cu: CuO/GO-NC) for the separation and preconcentration of polycyclic aromatic hydrocarbons (PAHs), i.e. naphthalene (Nap), phenanthrene (Phe), anthracene (Ant), and pyrene (Pyr), in vegetable (onion, tomato, carrot, herb, watermelon, lettuce, eggplant, and chili pepper), fruit (apple, watermelon, and grape), wastewater, and water samples. The MD-mu-SPE of PAHs in matrix samples was carried out, and the impacts of pH, ionic strength, extraction time, temperature, eluent volume, and sorbent mass on the recovery of PAHs were investigated by using Placket-Burman design (PBD). In addition, by using the central composite design (CCD), the best combination of each important variable was measured. Sorbent mass of 14 mg, eluent volume of 200 mu L, and 12 min extraction time at the central level of other factors were optimal conditions of pretreatment for the highest extraction recovery (ER%) of trace PAHs. Under the optimal conditions, the method proposed herein provided high enrichment factors ranged from 116.51 to 133.05, good linearity in the range of 10-3800 ng mL(-1) for Pyr, 3.0-3500 ng mL(-1) for Phe, 5.0-3200 ng mL(-1) for Nap, and 5.0-3000 ng mL(-1) for Ant with coefficient of determination (R-2) values between 0.9889 and 0.9963, low limits of detection (LOD) and quantification (LOQ) in the range of 0.015-0.061 and 0.485-2.034 ng mL(-1), respectively, and also satisfactory spiked recoveries (between 95.1% and 106.8%) with the relative standard deviations (RSDs) values in the range of 1.73%-5.62%. The Fe3O4/Cu: CuO/GO-NC-based MD-mu-SPE followed by HPLC-UV corroborated promising results for the convenient and effective determination of PAHs in the samples of vegetables, fruits, and environmental water. The results of this study revealed that our developed method is easy, feasible, precise, highly effective, and convenient to operate for the trace analysis of PAHs in different real samples. The extraction recovery was about 90% of the initial recovery after the sorbent usage for three times; therefore, the Fe3O4/Cu: CuO/GO-NC can readily be regenerated.
引用
下载
收藏
页数:13
相关论文
共 50 条
  • [21] An ultrasound assisted dispersive micro solid-phase extraction and a composite ionic liquid-metal organic framework for sixteen polycyclic aromatic hydrocarbons analysis in fruit juice and environmental water samples
    Pamik, Duygu Totur
    Bozkurt, Serap Seyhan
    Buyukkamaci, Nurdan
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1733
  • [22] Ultrasound-assisted magnetic solid-phase extraction of polycyclic aromatic hydrocarbons and nitrated polycyclic aromatic hydrocarbons from water samples with a magnetic polyaniline modified graphene oxide nanocomposite
    Manousi, N.
    Deliyanni, E. A.
    Rosenberg, E.
    Zachariadis, G. A.
    JOURNAL OF CHROMATOGRAPHY A, 2021, 1645
  • [23] Magnetic nanocomposite as sorbent for magnetic solid phase extraction coupled with high performance liquid chromatography for determination of polycyclic aromatic hydrocarbons
    Yang, Xiupei
    Yin, Yanru
    Zong, Yingying
    Wan, Ting
    Liao, Xiangjun
    MICROCHEMICAL JOURNAL, 2019, 145 : 26 - 34
  • [24] Dispersive micro-solid phase extraction of 16 priority polycyclic aromatic hydrocarbons from water by using thermally treated clinoptilolite, and their quantification by GC-MS
    Slobodan Ćirić
    Violeta Mitić
    Snežana Jovanović
    Marija Ilić
    Jelena Nikolić
    Gordana Stojanović
    Vesna Stankov Jovanović
    Microchimica Acta, 2018, 185
  • [25] Dispersive micro-solid phase extraction based on self-assembling, ionic liquid-coated magnetic particles for the determination of clofentezine and chlorfenapyr in environmental water samples
    Peng, Bing
    Zhang, Jiaheng
    Lu, Runhua
    Zhang, Sanbing
    Zhou, Wenfeng
    Gao, Haixiang
    ANALYST, 2013, 138 (22) : 6834 - 6843
  • [26] Dispersive micro-solid phase extraction of 16 priority polycyclic aromatic hydrocarbons from water by using thermally treated clinoptilolite, and their quantification by GC-MS
    Ciric, Slobodan
    Mitic, Violeta
    Jovanovic, Snezana
    Ilic, Marija
    Nikolic, Jelena
    Stojanovic, Gordana
    Jovanovic, Vesna Stankov
    MICROCHIMICA ACTA, 2018, 185 (12)
  • [27] Hybridization of commercial polymeric microparticles and magnetic nanoparticles for the dispersive micro-solid phase extraction of nitroaromatic hydrocarbons from water
    Reyes-Gallardo, Emilia M.
    Lasarte-Aragones, Guillermo
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1271 : 50 - 55
  • [28] Liquid chromatographic determination of trace levels of nitrophenols in water samples after dispersive magnetic solid phase extraction
    Sohaniyan, Maryam
    Manoochehri, Mahboobeh
    Asli, Maryam Daghighi
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (23) : 3528 - 3534
  • [29] Poly-(ionic liquid) coated with magnetic nanoparticles for micro solid phase extraction of polycyclic aromatic hydrocarbons in food samples
    Yunus, Faizah Muhammad
    Alias, Yatimah
    Yahya, Noorfatimah
    Zain, Nur Nadhirah Mohamad
    Raoov, Muggundha
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2024, 41 (05): : 495 - 512
  • [30] Determination of organochlorine pesticides from juice samples using magnetic biochar-based dispersive micro-solid phase extraction in combination with dispersive liquid-liquid microextraction
    Ago, Kero Assefa
    Kitte, Shimeles Addisu
    Gure, Abera
    EMERGING CONTAMINANTS, 2024, 10 (01)