Removal of arsenic from drinking water: A comparative study between electrocoagulation-microfiltration and chemical coagulation-microfiltration processes

被引:91
|
作者
Calderon Molgora, Cesar [1 ]
Martin Dominguez, Alejandra [1 ]
Mundo Avila, Eloy [2 ]
Drogui, Patrick [3 ]
Buelna, Gerardo [4 ]
机构
[1] Mexican Inst Water Technol IMTA, Jiutepec 62550, Mor, Mexico
[2] Chem Grp Medifarma SA CV, Environm Engn UNAM, Mexico City, DF, Mexico
[3] Univ Quebec, INRS Eau Terre & Environm, Quebec City, PQ G1K 9A9, Canada
[4] Ctr Rech Ind Quebec, Quebec City, PQ G1P 4C7, Canada
关键词
Arsenic removal; Drinking water; Electrocoagulation; Chemical coagulation; Microfiltration; ENHANCED COAGULATION; WASTE-WATER; TOXICITY;
D O I
10.1016/j.seppur.2013.08.011
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experimental tests have been conducted to assess the effectiveness of a process combining electrocoagulation and microfiltration (EC-MF), which has been compared with a chemical coagulation coupled with microfiltration (CC-MF) for removal of arsenic (C-0 = 100 mu g/L) from drinking water. Different operating parameters such as iron concentration, reaction time, initial pH and degree of mixing inside the reactor were successively investigated. The best operating conditions (97% of As removal) were obtained at a pH of 7.0 and a concentration of 4.0 mg/L of Fe3+ using the CC-MF process. It took 26 h for the system to maintain a residual arsenic concentration below the limiting value (10 mu g/L) recommended by the World Health Organization (WHO). The treatment cost using CC-MF system was evatuated to USD$ 0.066 per cubic meter of treated water. By comparison, a treatment cost of USD$ 0.12 per cubic meter of treated water was recorded using EC-MF system operated in the best operating conditions (inter-electrode gap of 0.4 cm, a concentration of 4 mg/L of Fe3+ produced by anodic dissolution by maintaining a pH around 7.0). The residual arsenic concentration was maintained below the limiting value recommended during a period of 16 h of continuous mode operation. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:645 / 651
页数:7
相关论文
共 50 条
  • [21] Effects of water chemistry on arsenic removal from drinking water by electrocoagulation
    Wan, Wei
    Pepping, Troy J.
    Banerji, Tuhin
    Chaudhari, Sanjeev
    Giammar, Daniel E.
    [J]. WATER RESEARCH, 2011, 45 (01) : 384 - 392
  • [22] Impact of water chemistry on the removal of arsenic from drinking water by electrocoagulation
    Wan, Wei
    Pepping, Troy
    Giammar, Daniel
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [23] Arsenic Removal from High-Arsenic Water Sources by Coagulation and Electrocoagulation
    Lacasa, Engracia
    Saez, Cristina
    Canizares, Pablo
    Fernandez, Francisco J.
    Rodrigo, Manuel A.
    [J]. SEPARATION SCIENCE AND TECHNOLOGY, 2013, 48 (03): : 508 - 514
  • [24] Arsenic removal from drinking water during coagulation
    Hering, JG
    Chen, PY
    Wilkie, JA
    Elimelech, M
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 1997, 123 (08): : 800 - 807
  • [25] Chromium removal from drinking water by redox-assisted coagulation: Chemical versus electrocoagulation
    Martin-Dominguez, A.
    Rivera-Huerta, M. L.
    Perez-Castrejon, S.
    Garrido-Hoyos, S. E.
    Villegas-Mendoza, I. E.
    Gelover-Santiago, S. L.
    Drogui, P.
    Buelna, G.
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2018, 200 : 266 - 272
  • [26] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ucar, Ceren
    Baskan, Meltem Bilici
    Pala, Aysegul
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 30 (10) : 1889 - 1895
  • [27] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ceren Ucar
    Meltem Bilici Baskan
    Aysegul Pala
    [J]. Korean Journal of Chemical Engineering, 2013, 30 : 1889 - 1895
  • [28] Pilot Study of a Hybrid Process combining Oxidation- coagulation -microfiltration for Drinking Water Production from Surface Water
    Song, Yali
    Dong, Bingzhi
    Gao, Naiyun
    Yang, Yufang
    Chang, Chun
    [J]. PROGRESS IN CIVIL ENGINEERING, PTS 1-4, 2012, 170-173 : 2360 - +
  • [29] Boron removal from water by electrocoagulation, and comparison with chemical coagulation
    Chen, Ming
    Dollar, Orion
    Waseem, Saad
    Shafer-Peltier, Karen
    Randtke, Stephen
    Peltier, Edward
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2019, 257
  • [30] Removal of arsenic from drinking water by chemical precipitation - A modeling and simulation study of the physical-chemical processes
    Pal, Parimal
    Ahammad, Sk. Ziauddin
    Pattanayak, Abhinandan
    Bhattacharya, Pinaki
    [J]. WATER ENVIRONMENT RESEARCH, 2007, 79 (04) : 357 - 366