Arsenic removal from drinking water by electrocoagulation using iron electrodes

被引:0
|
作者
Ceren Ucar
Meltem Bilici Baskan
Aysegul Pala
机构
[1] Dokuz Eylul University,Department of Environmental Engineering
[2] Pamukkale University,Department of Environmental Engineering
来源
关键词
Arsenic; Electrocoagulation; Drinking Water; Iron Electrodes; Iron Concentration;
D O I
暂无
中图分类号
学科分类号
摘要
Arsenic removal from drinking water was investigated using electrocoagulation (EC) followed by filtration. A sand filter was used to remove flocs generated in the EC process. Experiments were performed in a batch electrochemical reactor using iron electrodes with monopolar parallel electrode connection mode to assess their efficiency. The effects of several operating parameters on arsenic removal such as current density (1.5–9.0 mA cm−2), initial arsenic concentration (50–500 μg L−1), operating time (0–15 min), electrode surface area (266–665 cm2), and sodium chloride concentrations (0.01 and 0.02M) were examined. The EC process was able to decrease the residual arsenic concentration to less than 10 μg L−1. Optimum operating conditions were determined as an operating time of 5 min and current density of 4.5 mA cm−2 at pH of 7. The optimum electrode surface area for arsenic removal was found to be 266 cm2 taking into consideration cost effectiveness. The residual iron concentration increased with increasing residence time, and maximum residual iron value was measured as 287 μg L−1 for electrode surface area of 266 cm2. The addition of sodium chloride had no significant effect on residual arsenic concentration, but an increase in current density was observed.
引用
收藏
页码:1889 / 1895
页数:6
相关论文
共 50 条
  • [1] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ucar, Ceren
    Baskan, Meltem Bilici
    Pala, Aysegul
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 30 (10) : 1889 - 1895
  • [2] Arsenic removal from drinking water by electrocoagulation using iron electrodes- an understanding of the process parameters
    Banerji, Tuhin
    Chaudhari, Sanjeev
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2016, 4 (04): : 3990 - 4000
  • [3] Removal of arsenic from drinking water by the electrocoagulation using Fe and Al electrodes
    Kobya, M.
    Gebologlu, U.
    Ulu, F.
    Oncel, S.
    Demirbas, E.
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (14) : 5060 - 5070
  • [4] IRON ELECTROCOAGULATION MECHANISM FOR ARSENIC REMOVAL FROM AS-CONTAMINATED GROUNDWATER USING IRON ELECTRODES
    Nadege, Tanga Lafouet
    Wang, Yanxin
    Xie, Xianjun
    de la Paix, Mupenzi Jean
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2010, 19 (11A): : 2727 - 2735
  • [5] Effects of water chemistry on arsenic removal from drinking water by electrocoagulation
    Wan, Wei
    Pepping, Troy J.
    Banerji, Tuhin
    Chaudhari, Sanjeev
    Giammar, Daniel E.
    [J]. WATER RESEARCH, 2011, 45 (01) : 384 - 392
  • [6] Impact of water chemistry on the removal of arsenic from drinking water by electrocoagulation
    Wan, Wei
    Pepping, Troy
    Giammar, Daniel
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 239
  • [7] Mercury(II) removal from water by electrocoagulation using aluminium and iron electrodes
    Nanseu-Njiki, Charles Peguy
    Tchamango, Serge Raoul
    Ngom, Philippe Claude
    Darchen, Andre
    Ngameni, Emmanuel
    [J]. JOURNAL OF HAZARDOUS MATERIALS, 2009, 168 (2-3) : 1430 - 1436
  • [8] Removal of Arsenic from Drinking Water by Batch and Continuous Electrocoagulation Processes Using Hybrid Al-Fe Plate Electrodes
    Kobya, M.
    Akyol, A.
    Demirbas, E.
    Oncel, M. S.
    [J]. ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2014, 33 (01) : 131 - 140
  • [9] Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes
    Can, Berrin Zeliha
    Boncukcuoglu, Recep
    Yilmaz, Alper Erdem
    Fil, Baybars Ali
    [J]. JOURNAL OF ENVIRONMENTAL HEALTH SCIENCE AND ENGINEERING, 2014, 12
  • [10] Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes
    Berrin Zeliha Can
    Recep Boncukcuoglu
    Alper Erdem Yilmaz
    Baybars Ali Fil
    [J]. Journal of Environmental Health Science and Engineering, 12