Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes

被引:85
|
作者
Can, Berrin Zeliha [1 ]
Boncukcuoglu, Recep [2 ]
Yilmaz, Alper Erdem [2 ]
Fil, Baybars Ali [2 ,3 ]
机构
[1] Eighth Reg Directorate State Hydraul Works DSI, Erzurum, Turkey
[2] Ataturk Univ, Fac Engn, Dept Environm Engn, Erzurum, Turkey
[3] Balikesir Univ, Fac Engn, Dept Environm Engn, Balikesir, Turkey
关键词
Arsenic removal; Electrocoagulation; Wastewater treatment; Iron electrode; WASTE-WATER TREATMENT; AQUEOUS-SOLUTIONS; REVERSE-OSMOSIS; DRINKING-WATER; GROUNDWATER; WASTEWATERS; SULFATE;
D O I
10.1186/2052-336X-12-95
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Arsenic contamination of drinking water is a global problem that will likely become more apparent in future years as scientists and engineers measure the true extent of the problem. Arsenic poisoning is preventable though as there are several methods for easily removing even trace amounts of arsenic from drinking water. In the present study, electrocoagulation was evaluated as a treatment technology for arsenic removal from aqueous solutions. The effects of parameters such as initial pH, current density, initial concentration, supporting electrolyte type and stirring speed on removal efficiency were investigated. It has been observed that initial pH was highly effective on the arsenic removal efficiency. The highest removal efficiency was observed at initial pH = 4. The obtained experimental results showed that the efficiency of arsenic removal increased with increasing current density and decreased with increasing arsenic concentration in the solution. Supporting electrolyte had not significant effects on removal, adding supporting electrolyte decreased energy consumption. The effect of stirring speed on removal efficiency was investigated and the best removal efficiency was at the 150 rpm. Under the optimum conditions of initial pH 4, current density of 0.54 mA/cm(2), stirring speed of 150 rpm, electrolysis time of 30 minutes, removal was obtained as 99.50%. Energy consumption in the above conditions was calculated as 0.33 kWh/m(3). Electrocoagulation with iron electrodes was able to bring down 50 mg/L arsenic concentration to less than 10 mu g/L at the end of electrolysis time of 45 minutes with low electrical energy consumption as 0.52 kWh/m(3).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Effect of some operational parameters on the arsenic removal by electrocoagulation using iron electrodes
    Berrin Zeliha Can
    Recep Boncukcuoglu
    Alper Erdem Yilmaz
    Baybars Ali Fil
    [J]. Journal of Environmental Health Science and Engineering, 12
  • [2] Removal of total chromium from landfill leachate by electrocoagulation process using iron electrodes: effect of some major operational and chemical parameters
    Maiti, Sanjib Kumar
    Hazra, Tumpa
    Debsarkar, Anupam
    [J]. JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2020, 97 (11B) : 2453 - 2460
  • [3] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ucar, Ceren
    Baskan, Meltem Bilici
    Pala, Aysegul
    [J]. KOREAN JOURNAL OF CHEMICAL ENGINEERING, 2013, 30 (10) : 1889 - 1895
  • [4] Arsenic removal from drinking water by electrocoagulation using iron electrodes
    Ceren Ucar
    Meltem Bilici Baskan
    Aysegul Pala
    [J]. Korean Journal of Chemical Engineering, 2013, 30 : 1889 - 1895
  • [5] Arsenic removal from drinking water by electrocoagulation using iron electrodes- an understanding of the process parameters
    Banerji, Tuhin
    Chaudhari, Sanjeev
    [J]. JOURNAL OF ENVIRONMENTAL CHEMICAL ENGINEERING, 2016, 4 (04): : 3990 - 4000
  • [6] IRON ELECTROCOAGULATION MECHANISM FOR ARSENIC REMOVAL FROM AS-CONTAMINATED GROUNDWATER USING IRON ELECTRODES
    Nadege, Tanga Lafouet
    Wang, Yanxin
    Xie, Xianjun
    de la Paix, Mupenzi Jean
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2010, 19 (11A): : 2727 - 2735
  • [7] Effect of operational parameters on the removal of phenol from aqueous solutions by electrocoagulation using Fe and Al electrodes
    Kobya, Mehmet
    Demirbas, Erhan
    Sahin, Oguz
    [J]. DESALINATION AND WATER TREATMENT, 2012, 46 (1-3) : 366 - 374
  • [8] Effect of operational parameters on heavy metal removal by electrocoagulation
    Bhagawan, D.
    Poodari, Saritha
    Pothuraju, Tulasiram
    Srinivasulu, D.
    Shankaraiah, G.
    Rani, M. Yamuna
    Himabindu, V.
    Vidyavathi, S.
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2014, 21 (24) : 14166 - 14173
  • [9] Effect of operational parameters on heavy metal removal by electrocoagulation
    D. Bhagawan
    Saritha Poodari
    Tulasiram Pothuraju
    D. Srinivasulu
    G. Shankaraiah
    M. Yamuna Rani
    V. Himabindu
    S. Vidyavathi
    [J]. Environmental Science and Pollution Research, 2014, 21 : 14166 - 14173
  • [10] REMOVAL OF CARBAMAZEPINE BY ELECTROCOAGULATION: INVESTIGATION OF SOME KEY OPERATIONAL PARAMETERS
    Yehya, Tania
    Favier, Lidia
    Kadmi, Yassine
    Audonnet, Fabrice
    Fayad, Nidal
    Gavrilescu, Maria
    Vial, Christophe
    [J]. ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2015, 14 (03): : 639 - 645