A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives

被引:46
|
作者
Cevik, Emre [2 ]
Senel, Mehmet [1 ]
Baykal, Abdulhadi [1 ]
Abasiyanik, M. Fatih [2 ]
机构
[1] Fatih Univ, Dept Chem, Fac Arts & Sci, TR-34500 Istanbul, Turkey
[2] Fatih Univ, Fac Engn, Dept Genet & Bioengn, TR-34500 Istanbul, Turkey
关键词
Horseradish peroxidase; Magnetic nanomaterials; Biosensor; Phenol; HORSERADISH-PEROXIDASE; HYDROGEN-PEROXIDE; GLUCOSE-OXIDASE; COVALENT IMMOBILIZATION; TYROSINASE; ELECTRODE; NANOBIOCOMPOSITE; CONDUCTIVITY; MICROSPHERES; FERROCENE;
D O I
10.1016/j.snb.2012.07.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of amperometric phenol biosensor was fabricated for the determination of phenol and its derivatives such as, phenol, catechol, p-cresol, 2-aminophenol and pyrogallol. The telomere of poly(glycidylmethacrylate) (PGMA) with a trimethoxysilyl terminal group was synthesized by telomerization of glycidylmethacrylate. Iron oxide nanoparticles were coated with telomere of poly(glycidylmethacrylate) in order to obtain good enzyme immobilization platform. PGMA covered Fe3O4 was covalently attached Au electrode surface and horseradish peroxidase (HRP) was immobilized on nanoparticles covered surface, respectively. The telomere, nanoparticles and modified electrodes were characterized by Fourier transform infrared (FT-IR), X-ray diffraction (XRD), transmission electron microscopy (TEM) and cyclic voltammetry (CV) before and after immobilization of HRP. Amperometric response was measured as a function of substrate concentration, at a fixed potential of -0.50 V vs. Ag/AgCl in phosphate-buffered saline (pH 7.5). Analytical parameters for the fabricated phenol biosensor were obtained from the calibration curves. The basic features (optimum pH, optimum temperature, reusability, and storage stability) of the enzyme electrode were determined. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:396 / 405
页数:10
相关论文
共 50 条
  • [31] AP-GOD BIOSENSOR BASED ON A MODIFIED POLY(PHENOL) FILM ELECTRODE AND ITS APPLICATION IN THE DETERMINATION OF LOW-LEVELS OF PHOSPHATE
    SU, YS
    MASCINI, M
    ANALYTICAL LETTERS, 1995, 28 (08) : 1359 - 1378
  • [32] A novel amperometric biosensor based on ZnO nanoparticles-modified carbon paste electrode for determination of glucose in human serum
    Aydogdu, Gozde
    Zeybek, Derya Koyuncu
    Pekyardimci, Sule
    Kilic, Esma
    ARTIFICIAL CELLS NANOMEDICINE AND BIOTECHNOLOGY, 2013, 41 (05) : 332 - 338
  • [33] Amperometric and Impedimetric H2O2 Biosensor Based on Horseradish Peroxidase Covalently Immobilized at Ruthenium Oxide Nanoparticles Modified Electrode
    Periasamy, Arun Prakash
    Ting, Shan Wei
    Chen, Shen-Ming
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2011, 6 (07): : 2688 - 2709
  • [34] Electrocatalytic oxidation of hydrazine on magnetic bar carbon paste electrode modified with benzothiazole and iron oxide nanoparticles: Simultaneous determination of hydrazine and phenol
    Benvidi, Ali
    Jahanbani, Shahriar
    Mirjalili, Bibi-Fatemeh
    Zare, Reza
    CHINESE JOURNAL OF CATALYSIS, 2016, 37 (04) : 549 - 560
  • [35] Amperometric determination of heavy metal using an HRP inhibition biosensor based on ITO nanoparticles-ruthenium (III) hexamine trichloride composite: Central composite design optimization
    Dalkiran, Berna
    BIOELECTROCHEMISTRY, 2020, 135
  • [36] A novel amperometric biosensor based on gold nanoparticles anchored on reduced graphene oxide for sensitive detection of L-lactate tumor biomarker
    Azzouzi, Sawsen
    Rotariu, Lucian
    Benito, Ana M.
    Maser, Wolfgang K.
    Ben Ali, Mounir
    Bala, Camelia
    BIOSENSORS & BIOELECTRONICS, 2015, 69 : 280 - 286
  • [37] Electrochemical Biosensor Based on Gherkin (Cucumis anguria) Peroxidase Immobilized on Chitosan-Coated Iron Oxide Nanoparticles for Phenolic Compounds Detection
    Ananias Reis, Daniel
    Caon, Natalia Bruzamarello
    Giuliana, Valentini
    Alexandre Luis, Parize
    Rosane Nora, Castro
    Joao Victor, Nicolini
    de Oliveira, Ines Rosane Welter Zwirtes
    ELECTROANALYSIS, 2025, 37 (01)
  • [38] Amperometric Biosensor Based on a Semipermeable Poly-Meta-Phenylenediamine Membrane and Immobilized Lactate Oxidase for Highly Accurate L-Lactate Determination in Blood Serum
    Berketa, Kseniia
    Buzhak, Anhelina
    Vakhovskyi, Yevhen
    Mruga, Daryna
    Sverstiuk, Andrii
    Soldatkina, Olha
    Lyubovych, Olha
    Marchuk, Olga
    Dzyadevych, Serhii
    Soldatkin, Oleksandr
    ELECTROANALYSIS, 2025, 37 (01)
  • [39] A novel electrochemical biosensor based on horseradish peroxidase immobilized on Ag-nanoparticles/poly(L-arginine) modified carbon paste electrode toward the determination of pyrogallol/hydroquinone
    Raghu, P.
    Reddy, T. Madhusudana
    Reddaiah, K.
    Jaidev, L. R.
    Narasimha, G.
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 52 (6-7) : 377 - 385
  • [40] AN IN-SITU ELECTROSYNTHESIZED AMPEROMETRIC BIOSENSOR BASED ON LACTATE OXIDASE IMMOBILIZED IN A POLY-O-PHENYLENEDIAMINE FILM - DETERMINATION OF LACTATE IN SERUM BY FLOW-INJECTION ANALYSIS
    PALMISANO, F
    CENTONZE, D
    ZAMBONIN, PG
    BIOSENSORS & BIOELECTRONICS, 1994, 9 (07): : 471 - 479