A novel amperometric phenol biosensor based on immobilized HRP on poly(glycidylmethacrylate)-grafted iron oxide nanoparticles for the determination of phenol derivatives

被引:46
|
作者
Cevik, Emre [2 ]
Senel, Mehmet [1 ]
Baykal, Abdulhadi [1 ]
Abasiyanik, M. Fatih [2 ]
机构
[1] Fatih Univ, Dept Chem, Fac Arts & Sci, TR-34500 Istanbul, Turkey
[2] Fatih Univ, Fac Engn, Dept Genet & Bioengn, TR-34500 Istanbul, Turkey
关键词
Horseradish peroxidase; Magnetic nanomaterials; Biosensor; Phenol; HORSERADISH-PEROXIDASE; HYDROGEN-PEROXIDE; GLUCOSE-OXIDASE; COVALENT IMMOBILIZATION; TYROSINASE; ELECTRODE; NANOBIOCOMPOSITE; CONDUCTIVITY; MICROSPHERES; FERROCENE;
D O I
10.1016/j.snb.2012.07.026
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new type of amperometric phenol biosensor was fabricated for the determination of phenol and its derivatives such as, phenol, catechol, p-cresol, 2-aminophenol and pyrogallol. The telomere of poly(glycidylmethacrylate) (PGMA) with a trimethoxysilyl terminal group was synthesized by telomerization of glycidylmethacrylate. Iron oxide nanoparticles were coated with telomere of poly(glycidylmethacrylate) in order to obtain good enzyme immobilization platform. PGMA covered Fe3O4 was covalently attached Au electrode surface and horseradish peroxidase (HRP) was immobilized on nanoparticles covered surface, respectively. The telomere, nanoparticles and modified electrodes were characterized by Fourier transform infrared (FT-IR), X-ray diffraction (XRD), transmission electron microscopy (TEM) and cyclic voltammetry (CV) before and after immobilization of HRP. Amperometric response was measured as a function of substrate concentration, at a fixed potential of -0.50 V vs. Ag/AgCl in phosphate-buffered saline (pH 7.5). Analytical parameters for the fabricated phenol biosensor were obtained from the calibration curves. The basic features (optimum pH, optimum temperature, reusability, and storage stability) of the enzyme electrode were determined. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:396 / 405
页数:10
相关论文
共 50 条
  • [21] A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode
    Cao, Shurui
    Yuan, Ruo
    Chai, Yaqin
    Zhang, Lingyan
    Li, Xuelian
    Gao, Fengxian
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2007, 30 (02) : 71 - 78
  • [22] Construction of an improved amperometric acrylamide biosensor based on hemoglobin immobilized onto carboxylated multi-walled carbon nanotubes/iron oxide nanoparticles/chitosan composite film
    Batra, Bhawna
    Lata, Suman
    Pundir, C. S.
    BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2013, 36 (11) : 1591 - 1599
  • [23] Construction of an improved amperometric acrylamide biosensor based on hemoglobin immobilized onto carboxylated multi-walled carbon nanotubes/iron oxide nanoparticles/chitosan composite film
    Bhawna Batra
    Suman Lata
    C. S. Pundir
    Bioprocess and Biosystems Engineering, 2013, 36 : 1591 - 1599
  • [24] A novel thin film amperometric urea biosensor based on urease-immobilized on poly(N-glycidylpyrrole-co-pyrrole)
    Bozgeyik, Ibrahim
    Senel, Mehmet
    Cevik, Emre
    Abasiyanik, M. Fatih
    CURRENT APPLIED PHYSICS, 2011, 11 (04) : 1083 - 1088
  • [25] An Electrochemical Biosensor with Nano-Interface for Lactate Detection Based on Lactate Dehydrogenase Immobilized on Iron Oxide Nanoparticles
    Chelliah, Muruganantham
    Nesakumar, Noel
    Thandavan, Kavitha
    Sethuraman, Swaminathan
    Krishnan, Uma Maheswari
    Rayappan, John Bosco Balaguru
    NANOSCIENCE AND NANOTECHNOLOGY LETTERS, 2014, 6 (03) : 242 - 249
  • [26] Amperometric biosensor for hypoxanthine based on immobilized xanthine oxidase on iron (III) meso-tetraphenylporphyrin nanoparticles modified glassy carbon electrode
    Li, Xiao-Hua
    Xie, Zong-Hong
    Min, Hong
    Xian, Yue-Zhong
    Jin, Li-Tong
    ANALYTICAL LETTERS, 2008, 41 (03) : 456 - 468
  • [27] A novel amperometric biosensor for determination of hydrogen peroxide based on nafion and polythionine as well as gold nanoparticles and gelatin as matrixes
    Zhu, Q
    Yuan, R
    Chai, YQ
    Zhuo, Y
    Zhang, Y
    Li, XL
    Wang, N
    ANALYTICAL LETTERS, 2006, 39 (03) : 483 - 494
  • [28] Electrochemical sensor based on reduced graphene oxide and molecularly imprinted poly(phenol) for D-xylose determination
    Pompeu Prado Moreira, Luiz Felipe
    Buffon, Edervaldo
    Stradiotto, Nelson Ramos
    TALANTA, 2020, 208
  • [29] A novel biocompatible magnetic iron oxide nanoparticles/hydrogel based on poly (acrylic acid) grafted onto starch for controlled drug release
    Ghasem Rezanejade Bardajee
    Zari Hooshyar
    Journal of Polymer Research, 2013, 20
  • [30] A novel biocompatible magnetic iron oxide nanoparticles/hydrogel based on poly (acrylic acid) grafted onto starch for controlled drug release
    Bardajee, Ghasem Rezanejade
    Hooshyar, Zari
    JOURNAL OF POLYMER RESEARCH, 2013, 20 (11)