Indoor environmental quality and energy use evaluation of a three-star green office building in China with field study

被引:12
|
作者
Zhou, Yan [1 ]
Cai, Jianmin [1 ]
Xu, Yiwen [1 ]
机构
[1] Ningbo Univ, Sch Civil & Environm Engn, Ningbo 315211, Zhejiang, Peoples R China
关键词
Green office building; indoor environment quality (IEQ); energy consumption; field test; evaluation indicator; OCCUPANT SATISFACTION; LEED; PERFORMANCE;
D O I
10.1177/1744259120944604
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In order to get more comprehensive operation performance on indoor environment quality (IEQ) and energy consumption, a long-time measurement and a field occupants' satisfaction survey on IEQ performance of the first three-star-operation-certified green office building in Ningbo city of China have been conducted, and environmental energy efficiency (EEE) also has been analyzed. Moreover, IEQ and energy consumption of the green case office building are compared with other green office example buildings of the same climate zone in other literatures. The results show that the actual indoor thermal environment of the green case office building isn't quite achieving the design goals with the Chinese standard of thermal comfort level II (GB 50736). Although indoor air quality of CO(2)concentration and visual environment are consistent with the design goals, the indoor relative humidity doesn't reach the design goal in most of the year. The questionnaire survey results illustrate that the green case building has a high occupants' satisfaction on IEQ. The comparison results show that there is no obvious difference in indoor temperature and visual environment between the green case building and the green office example buildings in other studies. The results of occupant's satisfaction and CO(2)concentration of the green case building are better than in other studies. However, the indoor relative humidity of the green case building in every season is much higher than in other researches. Energy use intensity (EUI) of the green case building is about 56.5 kWh/m(2)center dot a, which is much lower than the constraint value of the Chinese standard. The actual performance of the green case building is also evaluated by the indicator of EEE. The results of this article can provide useful reference for green building operational performance promotion and feedback for design phase optimization.
引用
收藏
页码:209 / 235
页数:27
相关论文
共 41 条
  • [1] Subjective and Objective Evaluation of the Thermal Environment in a Three-Star Green Office Building in China
    Gou, Zhonghua
    Lau, Stephen Siu-Yu
    Chen, Fengna
    [J]. INDOOR AND BUILT ENVIRONMENT, 2012, 21 (03) : 412 - 422
  • [2] Measured energy use and indoor environment quality in green office buildings in China
    Lin, Borong
    Liu, Yanchen
    Wang, Zhe
    Pei, Zufeng
    Davies, Mike
    [J]. ENERGY AND BUILDINGS, 2016, 129 : 9 - 18
  • [3] Comparative study on indoor environmental quality of green office buildings with different levels of energy use intensity
    Geng, Yang
    Lin, Borong
    Zhu, Yingxin
    [J]. BUILDING AND ENVIRONMENT, 2020, 168
  • [4] A field study on indoor environmental quality and energy savings of an office building integrated with underfloor air conditioning system in India
    Lakshmanan, Ramesh Krishnan
    Lachireddi, Gangadhara Kiran Kumar
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2023, 29 (02) : 109 - 130
  • [5] Climate change, building energy use, and indoor environmental quality
    Nazaroff, William W.
    [J]. INDOOR AIR, 2008, 18 (04) : 259 - 260
  • [6] Indoor environmental quality evaluation in a hot and arid climate: a case study of a higher education office building
    Abdou, Yasmin
    Kim, Young Ki
    Bande, Lindita
    [J]. 2020 11TH INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SCIENCE AND DEVELOPMENT (ICESD 2020), 2020, 167
  • [7] Monitored Indoor Environmental Quality of a Mass Timber Office Building: A Case Study
    Stenson, Jason
    Ishaq, Suzanne L.
    Laguerre, Aurelie
    Loia, Andrew
    MacCrone, Georgia
    Mugabo, Ignace
    Northcutt, Dale
    Riggio, Mariapaola
    Barbosa, Andre
    Gall, Elliott T.
    Van Den Wymelenberg, Kevin
    [J]. BUILDINGS, 2019, 9 (06)
  • [8] Indoor environmental quality in Korean green building certification criteriacertified office buildingsoccupant satisfaction and performance
    Sediso, Binyam Gr
    Lee, Myung Sik
    [J]. SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2016, 22 (05) : 606 - 618
  • [9] Building performance evaluation: Balancing energy and indoor environmental quality in a UK school building
    Jain, Nishesh
    Burman, Esfand
    Robertson, Craig
    Stamp, Samuel
    Shrubsole, Clive
    Aletta, Francesco
    Barrett, Edward
    Oberman, Tin
    Kang, Jian
    Raynham, Peter
    Mumovic, D.
    Davies, Mike
    [J]. BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2020, 41 (03): : 343 - 360
  • [10] Energy consumption, indoor environmental quality, and benchmark for office buildings in Hainan Province of China
    Xiang-fei Kong
    Shi-lei Lü
    Ya-juan Xin
    Wei Wu
    [J]. Journal of Central South University, 2012, 19 : 783 - 790