Subjective and Objective Evaluation of the Thermal Environment in a Three-Star Green Office Building in China

被引:46
|
作者
Gou, Zhonghua [1 ]
Lau, Stephen Siu-Yu
Chen, Fengna [2 ]
机构
[1] Univ Hong Kong, Dept Architecture, RB, Hong Kong, Hong Kong, Peoples R China
[2] Shenzhen Inst Bldg Res, Shenzhen, Peoples R China
关键词
Green building; Thermal environment; Post-occupancy study; Air-conditioning; Natural ventilation; SATISFACTION; PERFORMANCE; PORTFOLIO; FEEDBACK; COMFORT;
D O I
10.1177/1420326X11419311
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A post-occupancy study was carried out to investigate the thermal environment in a high-standard office building certified by China Three-star Green Building Label. The study included a subjective evaluation of the indoor environment quality and work performance. A total of 182 office workers responded to the questionnaire survey based on the Building Use Studies (BUS) Occupant Survey and Reporting Method. Objective measurements of the thermal environment (temperature and relative humidity) under mechanically and naturally ventilated conditions were also carried out in the building. Although the thermal environment satisfied the majority of respondents, 12% and 20% reported dissatisfaction with summer and winter temperatures, respectively. The complaint on summer temperature was mainly from those working close to the chilled air outlets of the air-conditioners. The perception of cold winter temperatures revealed the potential shortcomings of sustainable building design in humid subtropical climates, where natural ventilation and passive cooling would predominate in the sustainable design while cold air in winter would tend to be neglected. The purpose of this study was to investigate the reasons why green buildings succeeded or failed to meet occupants' perception and this could have an implication in the design decisions for green building practice.
引用
收藏
页码:412 / 422
页数:11
相关论文
共 50 条
  • [1] Indoor environmental quality and energy use evaluation of a three-star green office building in China with field study
    Zhou, Yan
    Cai, Jianmin
    Xu, Yiwen
    [J]. JOURNAL OF BUILDING PHYSICS, 2021, 45 (02) : 209 - 235
  • [2] SUBJECTIVE AND OBJECTIVE EVALUATION OF AN OFFICE ENVIRONMENT
    EIDE, I
    BRANDSDAL, E
    MALVIK, B
    [J]. ENVIRONMENT INTERNATIONAL, 1992, 18 (01) : 63 - 72
  • [3] Evaluating and comparing objective and subjective thermal comfort in a malaysian green office building: A case study
    Lakhiar, Muhammad Tarique
    Sanmargaraja, Shalini
    Olanrewaju, Abdullateef
    Lim, Chong Hooi
    Ponniah, Vignes
    Mathalamuthu, Anselm Dass
    [J]. CASE STUDIES IN THERMAL ENGINEERING, 2024, 60
  • [4] Evaluation of Indoor Environment Subjective Perception in Large Office Building
    Veverkova, Zuzana
    Kabele, Karel
    [J]. IAQ 2020: INDOOR ENVIRONMENTAL QUALITY PERFORMANCE APPROACHES, PT 2, 2022,
  • [5] Post-occupancy evaluation of the thermal environment in a green building
    Gou, Zhonghua
    Lau, Stephen Siu-Yu
    [J]. FACILITIES, 2013, 31 (7-8) : 357 - 371
  • [6] Evaluation of Thermal Comfort of the Internal Environment in Smart Home Using Objective and Subjective Factors
    Vanus, Jan
    Martinek, Radek
    Bilik, Petr
    Zidek, Jan
    Skotnicova, Iveta
    [J]. 2016 17TH INTERNATIONAL SCIENTIFIC CONFERENCE ON ELECTRIC POWER ENGINEERING (EPE), 2016, : 524 - 528
  • [7] Environment - Building a "green" railway in China
    Peng, Changhui
    Ouyang, Hua
    Gao, Qiong
    Jiang, Yuan
    Zhang, Feng
    Li, Jun
    Yu, Qiang
    [J]. SCIENCE, 2007, 316 (5824) : 546 - 547
  • [8] OBJECTIVE AND SUBJECTIVE THERMAL COMFORT EVALUATION IN HUNGARY
    Kajtar, Laszlo
    Nyers, Jozsef
    Szabo, Janos
    Ketskemety, Laszlo
    Herczeg, Levente
    Leitner, Anita
    Bokor, Balazs
    [J]. THERMAL SCIENCE, 2017, 21 (03): : 1409 - 1418
  • [9] Gender differences in environment evaluation for office building
    Bajc, Tamara
    Milanovic, Stefan
    [J]. 2019 4TH INTERNATIONAL CONFERENCE ON SMART AND SUSTAINABLE TECHNOLOGIES (SPLITECH), 2019, : 22 - 26
  • [10] Evaluation of Indoor Thermal Environment in a Radiant-Cooled-Floor Office Building in Malaysia
    Kwong, Qi Jie
    Arsad, Mohamad Afri
    Adam, Nor Mariah
    [J]. ADVANCES IN MECHANICAL AND MANUFACTURING ENGINEERING, 2014, 564 : 228 - 233