On the numerical investigation of cardiovascular balloon-expandable stent using finite element method

被引:28
|
作者
Azaouzi, M. [1 ]
Makradi, A. [1 ]
Petit, J. [2 ]
Belouettar, S. [1 ]
Polit, O. [2 ]
机构
[1] Ctr Rech Publ Henri Tudor, Adv Mat & Struct Dept, L-4002 Esch Sur Alzette, Luxembourg
[2] Univ Paris Ouest, LEME, F-92410 Ville Davray, France
关键词
Cardiovascular stent; Finite element analysis; Numerical simulation; Fatigue life prediction; Goodman diagram; FATIGUE; SIZE; COMPONENTS; BEHAVIOR; FRACTURE; DESIGN; STRUTS;
D O I
10.1016/j.commatsci.2013.05.043
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The present paper shows an effective methodology which is based on Finite Element Analysis (FEA) for the fatigue life prediction (FLP) of a Balloon-Expandable (BE) stent made of stainless steel material (AISI316L). BE stent is a tubular, often mesh-like, structure which is expanded inside a diseased (stenosed) artery segment to restore blood flow and keep the vessel open following angioplasty. With design lives of 10-15 years, fatigue life prediction of these devices is critical for the designer, as fatigue failure may occur after deployment inside the blood vessel due to the heart beating (typically 4 x 10(7) cycles/year). Therefore, it is crucial to study the effect of stenting conditions and stent design on the fatigue life of BE stents. The objective of this paper is to provide quantitative measures of the stent's stress amplitude and mean stress which are generated by the cardiac pulse pressure. This allows prediction of the device's life and optimization of stent designs. In this paper, numerical investigations were conducted using an effective approach based on the well-known stress-based Goodman Diagram (GD) for the FLP of a given stent design. It has been demonstrated that the percentage of artery's expansion as well as the dimensions of the struts (the fundamental structural unit that forms the stent), have both an impact on the fatigue behavior after stent deployment. (C) 2013 Elsevier B. V. All rights reserved.
引用
收藏
页码:326 / 335
页数:10
相关论文
共 50 条
  • [31] Modified 'dumbbell' technique: a simple and intuitive method to position balloon-expandable stent valves
    Ferrari, Enrico
    Niclauss, Lars
    Berdajs, Denis
    von Segesser, Ludwig Karl
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2012, 42 (06) : E163 - E165
  • [32] Balloon-expandable stent complications during endovascular grafting - Discussion
    Crew, JR
    VASCULAR SURGERY, 1996, 30 (04): : 299 - 299
  • [33] Disintegration of a Balloon-Expandable Stent in the Iliac Artery Upon Delivery
    Ozkan, Fuat
    Peynircioglu, Bora
    Canyigit, Murat
    Ergun, Onur
    Cil, Barbaros Erhan
    Cekirge, Saruhan
    EUROPEAN JOURNAL OF GENERAL MEDICINE, 2013, 10 : 90 - 93
  • [34] Balloon-Expandable Covered Stent Therapy of Complex Endovascular Pathology
    Giles, Heath
    Lesar, Christopher
    Erdoes, Luke
    Sprouse, Richard
    Myers, Stuart
    ANNALS OF VASCULAR SURGERY, 2008, 22 (06) : 762 - 768
  • [35] Characteristic mechanical properties of balloon-expandable peripheral stent systems
    Schmidt, W
    Andresen, R
    Behrens, P
    Schmitz, KP
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2002, 174 (11): : 1430 - 1437
  • [36] A BALLOON-EXPANDABLE INTRAVASCULAR STENT FOR OBLITERATING EXPERIMENTAL AORTIC DISSECTION
    TRENT, MS
    PARSONNET, V
    SHOENFELD, R
    BRENER, BJ
    EISENBUD, DE
    NOVICK, AS
    CAMPBELL, AY
    FERRARARYAN, M
    VILLANUEVA, A
    JOURNAL OF VASCULAR SURGERY, 1990, 11 (05) : 707 - 717
  • [37] Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening
    Rahinj, Ganesh B.
    Chauhan, Harshit S.
    Sirivella, Martin L.
    Satyanarayana, Menta, V
    Ramanan, Laxminarayanan
    CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2022, 13 (02) : 247 - 264
  • [38] Kissing balloon-expandable iliac stents complicated by stent fracture
    Sawhney, Rajiv
    Allen, Derrick
    Nanavati, Sujal
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (10) : 1519 - 1520
  • [39] Effect of the Palmaz balloon-expandable metallic stent in the trachea of pigs
    Ruegemer, JL
    Perkins, JA
    Azarow, KS
    O'Bryant, LK
    Nielsen, RE
    Thomas, RW
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1999, 121 (01) : 92 - 97
  • [40] Numerical Analysis for Non-Uniformity of Balloon-Expandable Stent Deployment Driven by Dogboning and Foreshortening
    Ganesh B. Rahinj
    Harshit S. Chauhan
    Martin L. Sirivella
    Menta V. Satyanarayana
    Laxminarayanan Ramanan
    Cardiovascular Engineering and Technology, 2022, 13 : 247 - 264