Electrical Isolation of the Superior Vena Cava Using Upstream Phrenic Pacing to Avoid Phrenic Nerve Injury

被引:9
|
作者
Kimura, Takehiro
Takatsuki, Seiji [1 ]
Fukumoto, Kotaro
Nishiyama, Nobuhiro
Sato, Yuriko [2 ]
Aizawa, Yoshiyasu
Fukuda, Yukiko
Sato, Toshiaki [3 ]
Miyoshi, Shunichiro
Fukuda, Keiichi
机构
[1] Keio Univ, Sch Med, Dept Cardiol, Shinjuku Ku, Tokyo 1608582, Japan
[2] Kawakita Gen Hosp, Dept Cardiol, Tokyo, Japan
[3] Kyorin Univ Hosp, Dept Cardiol, Tokyo, Japan
来源
关键词
atrial fibrillation; catheter ablation; SVC isolation; phrenic nerve injury; phrenic pacing; ATRIAL-FIBRILLATION ABLATION; PULMONARY VEIN; CATHETER ABLATION; SINUS NODE; RADIOFREQUENCY ABLATION; INITIATION;
D O I
10.1111/j.1540-8159.2012.03465.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Phrenic nerve (PN) injury is a potential complication that can occur during superior vena cava (SVC) isolation to cure atrial fibrillation (AF). Avoiding radiofrequency (RF) energy delivery is the safer alternative but may result in failed isolation. High-output PN pacing above the ablation site (upstream PN pacing) to confirm whether the PN is intact is a promising technique to avoid PN injury. This study was conducted to elucidate the safety of delivering RF energy at the site of capture of the right PN using upstream high-output pacing during electrical SVC isolation. Methods: SVC isolation was conducted in 41 drug-resistant AF patients. When high-output pacing (25 mA) from the distal tip of the ablation catheter captured the PN at the right atrial-SVC junction, upstream PN pacing (cycle length: 10001500 ms) was applied during RF delivery. The application of RF energy was stopped upon the failure or weakness of diaphragmatic twitching. The feasibility of SVC isolation using upstream PN pacing was investigated. Results: In all 41 patients, SVC isolation was successfully achieved. RF energy was delivered at the PN capture site in 26 patients (154 +/- 138 second, 18 +/- 5 W), and upstream PN pacing was successfully applied in all of the patients. Out of 46 SVC isolations, including five repeated sessions, PN injury occurred in one patient, who recovered spontaneously within 2 weeks. Conclusions: Upstream PN pacing may be effective for the safe completion of SVC isolation and to reduce the severity of PN injury. (PACE 2012; 35:10531060)
引用
收藏
页码:1053 / 1060
页数:8
相关论文
共 50 条
  • [41] Diaphragm Activation in Ventilated Patients Using a Novel Transvenous Phrenic Nerve Pacing Catheter
    Reynolds, Steven
    Ebner, Adrian
    Meffen, Tracy
    Thakkar, Viral
    Gani, Matt
    Taylor, Kaity
    Clark, Linda
    Sadarangani, Gautam
    Meyyappan, Ramasamy
    Sandoval, Rodrigo
    Rohrs, Elizabeth
    Hoffer, Joaquin A.
    CRITICAL CARE MEDICINE, 2017, 45 (07) : E691 - E694
  • [42] Novel technique for significant reduction of phrenic nerve injury in cryoballoon pulmonary vein isolation
    Phkhaladze, K.
    Omran, H.
    Thale, J.
    Sciacca, V.
    Fink, T.
    Isgandarova, K.
    Braun, M.
    Khalaph, M.
    Guckel, D.
    El Hamriti, M.
    Sohns, C.
    Vogt, J.
    Sommer, P.
    Imnadze, G.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [43] Dormant conduction revealed by adenosine to guide electrical isolation of the superior vena cava
    Viles-Gonzalez, Juan F.
    Miller, Marc A.
    d'Avila, Andre
    EUROPACE, 2012, 14 (10): : 1419 - 1419
  • [44] Distortion of Right Superior Pulmonary Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury
    不详
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (10) : 1151 - 1157
  • [45] Distortion of Right Superior Pulmonar Vein Anatomy by Balloon Catheters as a Contributor to Phrenic Nerve Injury
    Okumura, Yasuo
    Henz, Benhur D.
    Johnson, Susan B.
    Bunch, T. J.
    Packer, Douglas L.
    CIRCULATION, 2008, 118 (18) : S587 - S587
  • [46] Electrical isolation of the superior vena cava using second-generation cryoballoon in patients with atrial fibrillation
    Wei, Hui-Qiang
    Guo, Xiao-Gang
    Sun, Qi
    Yang, Jian-Du
    Xie, Hai-Yang
    Cao, Zhong-Jing
    Chen, Yan-Qiao
    Zhang, Shu
    Wu, Shulin
    Ma, Jian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (06) : 1307 - 1314
  • [47] Evaluation of a standardized approach using optimized and contiguous RF applications for electrical isolation of the superior vena cava
    Hilfiker, Gabriela
    De Becker, Benjamin
    El Haddad, Milad
    O'Neill, Louisa
    Gillis, Kris
    Wielandts, Jean-Yves
    Tavernier, Rene
    De Waroux, Jean-Benoit Le Polain
    Duytschaever, Mattias
    Knecht, Sebastien
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2023, 46 (02): : 198 - 200
  • [48] Phrenic nerve injury after 16 years of diaphragmatic pacing in Congenital Central Alveolar Hypoventilation Syndrome
    Goswami, U.
    Kannapiran, M.
    Iber, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2010, 181
  • [49] Left-sided phrenic nerve injury during redo pulmonary vein isolation long after a previous contralateral self-limiting phrenic nerve palsy
    Kis, Zsuzsanna
    Noten, Anna Maria Elisabeth
    Wijchers, Sip
    Bhagwandien, Rohit
    Szili-Torok, Tamas
    CLINICAL CASE REPORTS, 2019, 7 (07): : 1391 - 1394
  • [50] Left phrenic nerve injury during electrical isolation of left-sided pulmonary veins with the second-generation cryoballoon
    Okishige, Kaoru
    Aoyagi, Hideshi
    Nishimura, Takurou
    Shigeta, Takatoshi
    Keida, Takehiko
    Yamauchi, Yasuteru
    Sasano, Tetsuo
    Hirao, Kenzo
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2017, 40 (12): : 1426 - 1431