A comparison of Trachway intubating stylet and Airway Scope for tracheal intubation by novice operators: A manikin study

被引:16
|
作者
Tseng, Kuang-Yi [1 ]
Chau, Siu-Wah [1 ,2 ]
Su, Miao-Pei [1 ]
Shih, Chih-Kai [1 ,3 ]
Lu, I-Cheng [1 ,2 ,3 ]
Cheng, Kuang-I [1 ,2 ,3 ]
机构
[1] Kaohsiung Med Univ Hosp, Dept Anesthesiol, Kaohsiung 807, Taiwan
[2] Kaohsiung Med Univ, Coll Med, Fac Med, Dept Anesthesiol, Kaohsiung, Taiwan
[3] Kaohsiung Med Univ, Coll Med, Grad Inst Med, Kaohsiung, Taiwan
来源
KAOHSIUNG JOURNAL OF MEDICAL SCIENCES | 2012年 / 28卷 / 08期
关键词
Airway Scope; Difficult intubation; Simulator; Trachway intubating; stylet; BULLARD LARYNGOSCOPE; VIDEO LARYNGOSCOPE; DIFFICULT; MANAGEMENT; FIBERSCOPE;
D O I
10.1016/j.kjms.2012.02.016
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The Trachway is a recently developed intubation device that resembles an illuminating stylet and incorporates a video-assisted system. This study evaluated the use of this system for tracheal intubation by novice operators. This randomized cross-over study compared the Trachway and the Airway Scope in simulated routine and difficult intubation scenarios. The difficult scenario was simulated by increasing the tongue volume of the manikin. The primary outcome measure in both airway scenarios was the time required for a successful tracheal intubation. For each scenario, the success rate, ease of intubation and operator preference were recorded for the two devices and compared. Average intubation time did not differ significantly between the Trachway and Airway Scope for the normal airway scenario (11.2 +/- 6.5 vs. 9.8 +/- 4.3 seconds, respectively; p = 0.07), but was significantly longer using the Trachway than with the Airway Scope on the difficult airway scenario (17.1 +/- 11.1 vs. 9.5 +/- 4.1 seconds, respectively; p < 0.001). The overall success rates of the Trachway and Airway Scope (96.3% and 98.6%, respectively) did not differ significantly (p = 0.13). Preference for the Airway Scope was greater in both scenarios, and particularly in the difficult airway scenario (p < 0.001). Although the devices are comparable in terms of ease of use and intubation time in normal scenarios, the ease of using the Airway Scope makes it more suitable for inexperienced operators in difficult intubation scenarios. Copyright (c) 2012, Elsevier Taiwan LLC. All rights reserved.
引用
收藏
页码:448 / 451
页数:4
相关论文
共 50 条
  • [21] Evaluation of tracheal intubation in several positions by the Pentax-AWS Airway Scope: a manikin study
    Nobuyasu Komasawa
    Ryusuke Ueki
    Motoi Itani
    Hajime Nomura
    Shin-ich Nishi
    Yoshiroh Kaminoh
    Journal of Anesthesia, 2010, 24 : 908 - 912
  • [22] Comparison of tracheal intubation by the Macintosh laryngoscope and Pentax-AWS (Airway Scope) during chest compression: a manikin study
    Nobuyasu Komasawa
    Ryusuke Ueki
    Hajime Nomura
    Motoi Itani
    Yoshiroh Kaminoh
    Journal of Anesthesia, 2010, 24 : 306 - 308
  • [23] Comparison of the Pentax Airway Scope® and McGrath® Videolaryngoscope with the Macintosh laryngoscope in tracheal intubation by anaesthetists unfamiliar with videolaryngoscopes: a manikin study
    Sharma, D. -J.
    Weightman, W. M.
    Travis, A.
    ANAESTHESIA AND INTENSIVE CARE, 2010, 38 (01) : 39 - 42
  • [24] Tracheal intubation with restricted access: a randomised comparison of the Pentax-Airway Scope and Macintosh laryngoscope in a manikin
    Asai, T.
    ANAESTHESIA, 2009, 64 (10) : 1114 - 1117
  • [25] Tracheal intubation for a difficult airway using Airway scope®, KingVision® and McGRATH®: a comparative manikin study of inexperienced personnel
    J Itai
    Y Tanabe
    T Nishida
    T Inagawa
    Y Torikoshi
    Y Kida
    T Tamura
    K Ota
    T Otani
    T Sadamori
    K Une
    R Tsumura
    Y Iwasaki
    N Hirohashi
    K Tanigawal
    Critical Care, 17 (Suppl 2):
  • [26] A comparison of the Seeing Optical Stylet and the gum elastic bougie in simulated difficult tracheal intubation: a manikin study
    Evans, A
    Morris, S
    Petterson, J
    Hall, JE
    ANAESTHESIA, 2006, 61 (05) : 478 - 481
  • [27] Comparison of a New Video Intubation Stylet and McGrath® MAC Video Laryngoscope for Intubation in an Airway Manikin with Normal Airway and Cervical Spine Immobilization Scenarios by Novice Personnel: A Randomized Crossover Study
    Park, Jin-Woo
    An, Sungmin
    Park, Seongjoo
    Nahm, Francis Sahngun
    Han, Sung-Hee
    Kim, Jin-Hee
    BIOMED RESEARCH INTERNATIONAL, 2021, 2021
  • [28] Laryngoscopic versus intubating LMA guided tracheae intubation by novice users - A manikin study
    Timmermann, A.
    Russo, S. G.
    Crozier, T. A.
    Nickel, E. A.
    Kazmaier, S.
    Eich, C.
    Graf, B. M.
    RESUSCITATION, 2007, 73 (03) : 412 - 416
  • [29] A manikin study to compare video-optical intubation stylet versus Macintosh laryngoscope used by novice in normal and simulated difficult airway intubation
    Tsui, K. L.
    Hung, C. Y.
    Kam, C. W.
    HONG KONG JOURNAL OF EMERGENCY MEDICINE, 2008, 15 (03) : 133 - 138
  • [30] Tracheal Intubation of a Difficult Airway Using Airway Scope, Airtraq, and Macintosh Laryngoscope: A Comparative Manikin Study of Inexperienced Personnel
    Liu, Liangji
    Tanigawa, Koichi
    Kusunoki, Shinji
    Tamura, Tomoko
    Ota, Kohei
    Yamaga, Satoshi
    Kida, Yoshiko
    Otani, Tadatsugu
    Sadamori, Takuma
    Takeda, Taku
    Iwasaki, Yasumasa
    Hirohashi, Nobuyuki
    ANESTHESIA AND ANALGESIA, 2010, 110 (04): : 1049 - 1055