Carotid Artery Angioplasty and Stenting Without Distal Embolic Protection Devices

被引:11
|
作者
Binning, Mandy J. [1 ]
Maxwell, Christina R. [1 ]
Stofko, Douglas [2 ]
Zerr, Myra [3 ,4 ,5 ,6 ]
Maghazehe, Kamyar [3 ,4 ,5 ,6 ]
Liebman, Kenneth [1 ]
Hakma, Zakaria [1 ]
Lewis-Diaz, Cynthia [3 ,4 ,5 ,6 ]
Veznedaroglu, Erol [1 ]
机构
[1] Drexel Neurosci Inst, 219 Broad St, Philadelphia, PA 19107 USA
[2] Tennova Neurosci, Knoxville, TN USA
[3] Capital Hlth Reg Med Ctr, Trenton, NJ USA
[4] Capital Inst Neurosci, Trenton, NJ USA
[5] Capital Hlth Reg Med Ctr, Pennington, NJ USA
[6] Capital Inst Neurosci, Pennington, NJ USA
关键词
Angioplasty; Carotid artery; Embolic protection device; Stenting; RANDOMIZED-TRIAL; ENDARTERECTOMY; STENOSIS; FILTER;
D O I
10.1227/NEU.0000000000001367
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND: Embolic protection devices are used during carotid artery stenting procedures to reduce risk of distal embolization. Although this is a standard procedural recommendation, no studies have shown superiority of these devices over unprotected stenting procedures. OBJECTIVE: To assess the periprocedural outcomeand durability of carotid artery stenting without embolic protection devices and poststent angioplasty. METHODS: We performed a retrospective chart review of 174 carotid angioplasty stent procedures performed at our institution. One hundred sixty-six patients underwent angioplasty and stenting without distal protection devices or poststent angioplasty. Complications related to stenting, including procedural complications, postoperative stroke and/or myocardial infarction, and stent restenosis were analyzed. RESULTS: One hundred thirty-five stents (78%) were performed in symptomatic patients, whereas 22% of stents were placed for asymptomatic internal carotid artery stenosis. The degree of stenosis was 80% or greater in 75% of patients and 90% or greater in 55% of patients. Following the stenting procedure, the 24-hour and 30-day rate of transient ischemic attack, intracranial hemorrhage, or ischemic stroke was 0. Three (2%) patients had a perioperative, non-ST elevation myocardial infarction. Five patients (2.8%) required treatment for restenosis (> 50% stenosis from baseline), 1 of which was symptomatic. CONCLUSION: Our data show that carotid artery stenting without the use of embolic protection devices and without postangioplasty stenting, in experienced hands, can be performed safely. Furthermore, this technique does not result in a higher degree of in-stent restenosis than series in which poststenting angioplasty is performed.
引用
收藏
页码:60 / 64
页数:5
相关论文
共 50 条
  • [31] Embolic protection for carotid artery stenting - A 'no brainer'
    Aronow, HD
    Yadav, JS
    ACTA CHIRURGICA BELGICA, 2004, 104 (01) : 65 - 70
  • [32] Distal embolic protection devices, high intensity transient signals and neurological outcomes during carotid artery stenting
    Gruberg, L
    Nair, P
    Kerner, A
    Petchersky, S
    Kouperberg, E
    Beyar, R
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (04) : 31B - 31B
  • [33] Immunohistochemical Analysis of Debris Captured by Filter-Type Distal Embolic Protection Devices for Carotid Artery Stenting
    Kambayashi, Yukinao
    Yuki, Ichiro
    Ishibashi, Toshihiro
    Ikemura, Ayako
    Umezawa, Takashi
    Suzuki, Masafumi
    Kan, Issei
    Takao, Hiroyuki
    Murayama, Yuichi
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2017, 26 (04): : 816 - 822
  • [34] Renal angioplasty and stenting: Role of embolic protection devices
    Henry, M
    Henry, I
    Polydorou, A
    Polydorou, A
    Le Borgne, E
    Hugel, M
    CIRCULATION, 2004, 110 (17) : 614 - 614
  • [35] Embolic protection devices for carotid artery stenting: A network meta-analysis
    Giannopoulos, Stefanos
    Sagris, Marios
    Giannopoulos, Spyridon
    Tzoumas, Andreas
    Kokkinidis, Damianos G.
    Texakalidis, Pavlos
    Koutsias, George
    Volteas, Panagiotis
    Jing, Li
    Malgor, Rafael D.
    VASCULAR, 2024, 32 (02) : 447 - 457
  • [36] Embolic Protection Devices for Carotid Artery Stenting: A Network Meta-Analysis
    Giannopoulos, Stefanos
    Sagris, Marios
    Giannopoulos, Spyridon
    Tzoumas, Andreas
    Kokkinidis, Damianos G.
    Texakalidis, Pavlos
    Koutsias, George
    Volteas, Panagiotis
    Li, Jing
    Malgor, Rafael D.
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (04) : 17S - 18S
  • [37] Distal protection devices enhance the safety of carotid artery stenting.
    Weisz, G
    Iyer, SS
    Vitek, JJ
    Brennan, C
    Dangas, G
    New, G
    Roubin, GS
    AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (6A): : 50L - 50L
  • [38] Do we need distal protection devices in carotid artery stenting?
    Han, SH
    Kang, WC
    Oh, KJ
    Ahn, TH
    Shin, EK
    AMERICAN JOURNAL OF CARDIOLOGY, 2006, 97 (8B): : 53D - 53D
  • [39] Iatrogenic vasospasm in carotid artery stent angioplasty with distal protection devices
    Schirmer, Clemens M.
    Hoit, Daniel A.
    Malek, Adel M.
    NEUROSURGICAL FOCUS, 2008, 24 (02)
  • [40] CAROTID STENTING WITHOUT USE OF DISTAL PROTECTION DEVICES: SAFETY AND EFFICACY
    Siddheswar, B.
    Rajendra, P.
    Ramesh, N.
    Ramataraknath, V.
    Sravanthi, B.
    Haritha, A.
    Sarma, P. V. Raghava
    Vijaya, P.
    INTERNATIONAL JOURNAL OF STROKE, 2016, 11 (SUPP 3) : 224 - 224